Cargando…

Patient‐derived heterogeneous breast phantoms for advanced dosimetry in mammography and tomosynthesis

BACKGROUND: Understanding the magnitude and variability of the radiation dose absorbed by the breast fibroglandular tissue during mammography and digital breast tomosynthesis (DBT) is of paramount importance to assess risks versus benefits. Although homogeneous breast models have been proposed and u...

Descripción completa

Detalles Bibliográficos
Autores principales: Caballo, Marco, Rabin, Carolina, Fedon, Christian, Rodríguez‐Ruiz, Alejandro, Diaz, Oliver, Boone, John M., Dance, David R., Sechopoulos, Ioannis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9546119/
https://www.ncbi.nlm.nih.gov/pubmed/35635844
http://dx.doi.org/10.1002/mp.15785
_version_ 1784804971437359104
author Caballo, Marco
Rabin, Carolina
Fedon, Christian
Rodríguez‐Ruiz, Alejandro
Diaz, Oliver
Boone, John M.
Dance, David R.
Sechopoulos, Ioannis
author_facet Caballo, Marco
Rabin, Carolina
Fedon, Christian
Rodríguez‐Ruiz, Alejandro
Diaz, Oliver
Boone, John M.
Dance, David R.
Sechopoulos, Ioannis
author_sort Caballo, Marco
collection PubMed
description BACKGROUND: Understanding the magnitude and variability of the radiation dose absorbed by the breast fibroglandular tissue during mammography and digital breast tomosynthesis (DBT) is of paramount importance to assess risks versus benefits. Although homogeneous breast models have been proposed and used for decades for this purpose, they do not accurately reflect the actual heterogeneous distribution of the fibroglandular tissue in the breast, leading to biases in the estimation of dose from these modalities. PURPOSE: To develop and validate a method to generate patient‐derived, heterogeneous digital breast phantoms for breast dosimetry in mammography and DBT. METHODS: The proposed phantoms were developed starting from patient‐based models of compressed breasts, generated for multiple thicknesses and representing the two standard views acquired in mammography and DBT, that is, cranio‐caudal (CC) and medio‐lateral‐oblique (MLO). Internally, the breast phantoms were defined as consisting of an adipose/fibroglandular tissue mixture, with a nonspatially uniform relative concentration. The parenchyma distributions were obtained from a previously described model based on patient breast computed tomography data that underwent simulated compression. Following these distributions, phantoms with any glandular fraction (1%–100%) and breast thickness (12–125 mm) can be generated, for both views. The phantoms were validated, in terms of their accuracy for average normalized glandular dose (D(g)N) estimation across samples of patient breasts, using 88 patient‐specific phantoms involving actual patient distribution of the fibroglandular tissue in the breast, and compared to that obtained using a homogeneous model similar to those currently used for breast dosimetry. RESULTS: The average D(g)N estimated for the proposed phantoms was concordant with that absorbed by the patient‐specific phantoms to within 5% (CC) and 4% (MLO). These D(g)N estimates were over 30% lower than those estimated with the homogeneous models, which overestimated the average D(g)N by 43% (CC), and 32% (MLO) compared to the patient‐specific phantoms. CONCLUSIONS: The developed phantoms can be used for dosimetry simulations to improve the accuracy of dose estimates in mammography and DBT.
format Online
Article
Text
id pubmed-9546119
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-95461192022-10-14 Patient‐derived heterogeneous breast phantoms for advanced dosimetry in mammography and tomosynthesis Caballo, Marco Rabin, Carolina Fedon, Christian Rodríguez‐Ruiz, Alejandro Diaz, Oliver Boone, John M. Dance, David R. Sechopoulos, Ioannis Med Phys COMPUTATIONAL AND EXPERIMENTAL DOSIMETRY BACKGROUND: Understanding the magnitude and variability of the radiation dose absorbed by the breast fibroglandular tissue during mammography and digital breast tomosynthesis (DBT) is of paramount importance to assess risks versus benefits. Although homogeneous breast models have been proposed and used for decades for this purpose, they do not accurately reflect the actual heterogeneous distribution of the fibroglandular tissue in the breast, leading to biases in the estimation of dose from these modalities. PURPOSE: To develop and validate a method to generate patient‐derived, heterogeneous digital breast phantoms for breast dosimetry in mammography and DBT. METHODS: The proposed phantoms were developed starting from patient‐based models of compressed breasts, generated for multiple thicknesses and representing the two standard views acquired in mammography and DBT, that is, cranio‐caudal (CC) and medio‐lateral‐oblique (MLO). Internally, the breast phantoms were defined as consisting of an adipose/fibroglandular tissue mixture, with a nonspatially uniform relative concentration. The parenchyma distributions were obtained from a previously described model based on patient breast computed tomography data that underwent simulated compression. Following these distributions, phantoms with any glandular fraction (1%–100%) and breast thickness (12–125 mm) can be generated, for both views. The phantoms were validated, in terms of their accuracy for average normalized glandular dose (D(g)N) estimation across samples of patient breasts, using 88 patient‐specific phantoms involving actual patient distribution of the fibroglandular tissue in the breast, and compared to that obtained using a homogeneous model similar to those currently used for breast dosimetry. RESULTS: The average D(g)N estimated for the proposed phantoms was concordant with that absorbed by the patient‐specific phantoms to within 5% (CC) and 4% (MLO). These D(g)N estimates were over 30% lower than those estimated with the homogeneous models, which overestimated the average D(g)N by 43% (CC), and 32% (MLO) compared to the patient‐specific phantoms. CONCLUSIONS: The developed phantoms can be used for dosimetry simulations to improve the accuracy of dose estimates in mammography and DBT. John Wiley and Sons Inc. 2022-06-08 2022-08 /pmc/articles/PMC9546119/ /pubmed/35635844 http://dx.doi.org/10.1002/mp.15785 Text en © 2022 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle COMPUTATIONAL AND EXPERIMENTAL DOSIMETRY
Caballo, Marco
Rabin, Carolina
Fedon, Christian
Rodríguez‐Ruiz, Alejandro
Diaz, Oliver
Boone, John M.
Dance, David R.
Sechopoulos, Ioannis
Patient‐derived heterogeneous breast phantoms for advanced dosimetry in mammography and tomosynthesis
title Patient‐derived heterogeneous breast phantoms for advanced dosimetry in mammography and tomosynthesis
title_full Patient‐derived heterogeneous breast phantoms for advanced dosimetry in mammography and tomosynthesis
title_fullStr Patient‐derived heterogeneous breast phantoms for advanced dosimetry in mammography and tomosynthesis
title_full_unstemmed Patient‐derived heterogeneous breast phantoms for advanced dosimetry in mammography and tomosynthesis
title_short Patient‐derived heterogeneous breast phantoms for advanced dosimetry in mammography and tomosynthesis
title_sort patient‐derived heterogeneous breast phantoms for advanced dosimetry in mammography and tomosynthesis
topic COMPUTATIONAL AND EXPERIMENTAL DOSIMETRY
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9546119/
https://www.ncbi.nlm.nih.gov/pubmed/35635844
http://dx.doi.org/10.1002/mp.15785
work_keys_str_mv AT caballomarco patientderivedheterogeneousbreastphantomsforadvanceddosimetryinmammographyandtomosynthesis
AT rabincarolina patientderivedheterogeneousbreastphantomsforadvanceddosimetryinmammographyandtomosynthesis
AT fedonchristian patientderivedheterogeneousbreastphantomsforadvanceddosimetryinmammographyandtomosynthesis
AT rodriguezruizalejandro patientderivedheterogeneousbreastphantomsforadvanceddosimetryinmammographyandtomosynthesis
AT diazoliver patientderivedheterogeneousbreastphantomsforadvanceddosimetryinmammographyandtomosynthesis
AT boonejohnm patientderivedheterogeneousbreastphantomsforadvanceddosimetryinmammographyandtomosynthesis
AT dancedavidr patientderivedheterogeneousbreastphantomsforadvanceddosimetryinmammographyandtomosynthesis
AT sechopoulosioannis patientderivedheterogeneousbreastphantomsforadvanceddosimetryinmammographyandtomosynthesis