Cargando…

Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac

BACKGROUND AND PURPOSE: Magnetic resonance-guided radiotherapy (MRgRT) with real-time intra-fraction tumor motion monitoring allows for high precision Stereotactic Ablative Radiotherapy (SABR). This study aimed to investigate the clinical feasibility, patient satisfaction and delivery accuracy of si...

Descripción completa

Detalles Bibliográficos
Autores principales: Palacios, Miguel A., Verheijen, Sonja, Schneiders, Famke L., Bohoudi, Omar, Slotman, Berend J., Lagerwaard, Frank J., Senan, Suresh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9547277/
https://www.ncbi.nlm.nih.gov/pubmed/36217429
http://dx.doi.org/10.1016/j.phro.2022.09.010
_version_ 1784805229891420160
author Palacios, Miguel A.
Verheijen, Sonja
Schneiders, Famke L.
Bohoudi, Omar
Slotman, Berend J.
Lagerwaard, Frank J.
Senan, Suresh
author_facet Palacios, Miguel A.
Verheijen, Sonja
Schneiders, Famke L.
Bohoudi, Omar
Slotman, Berend J.
Lagerwaard, Frank J.
Senan, Suresh
author_sort Palacios, Miguel A.
collection PubMed
description BACKGROUND AND PURPOSE: Magnetic resonance-guided radiotherapy (MRgRT) with real-time intra-fraction tumor motion monitoring allows for high precision Stereotactic Ablative Radiotherapy (SABR). This study aimed to investigate the clinical feasibility, patient satisfaction and delivery accuracy of single-fraction MR-guided SABR in a single day (one-stop-shop, OSS). METHODS AND MATERIALS: Ten patients with small lung tumors eligible for single fraction treatments were included. The OSS procedure consisted of consultation, treatment simulation, treatment planning and delivery. Following SABR delivery, patients completed a reported experience measure (PREM) questionnaire. Prescribed doses ranged 28–34 Gy. Median GTV was 2.2 cm(3) (range 1.3–22.9 cm(3)). A gating boundary of 3 mm, and PTV margin of 5 mm around the GTV, were used with auto-beam delivery control. Accuracy of SABR delivery was studied by analyzing delivered MR-cines reconstructed from machine log files. RESULTS: All 10 patients completed the OSS procedure in a single day, and all reported satisfaction with the process. Median time for the treatment planning step and the whole procedure were 2.8 h and 6.6 h, respectively. With optimization of the procedure, treatment could be completed in half a day. During beam-on, the 3 mm tracking boundary encompassed between 78.0 and 100 % of the GTV across all patients, with corresponding PTV values being 94.4–100 % (5th-95th percentiles). On average, system-latency for triggering a beam-off event comprised 5.3 % of the delivery time. Latency reduced GTV coverage by an average of −0.3 %. Duty-cycles during treatment delivery ranged from 26.1 to 64.7 %. CONCLUSIONS: An OSS procedure with MR-guided SABR for lung cancer led to good patient satisfaction. Gated treatment delivery was highly accurate with little impact of system-latency.
format Online
Article
Text
id pubmed-9547277
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-95472772022-10-09 Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac Palacios, Miguel A. Verheijen, Sonja Schneiders, Famke L. Bohoudi, Omar Slotman, Berend J. Lagerwaard, Frank J. Senan, Suresh Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Magnetic resonance-guided radiotherapy (MRgRT) with real-time intra-fraction tumor motion monitoring allows for high precision Stereotactic Ablative Radiotherapy (SABR). This study aimed to investigate the clinical feasibility, patient satisfaction and delivery accuracy of single-fraction MR-guided SABR in a single day (one-stop-shop, OSS). METHODS AND MATERIALS: Ten patients with small lung tumors eligible for single fraction treatments were included. The OSS procedure consisted of consultation, treatment simulation, treatment planning and delivery. Following SABR delivery, patients completed a reported experience measure (PREM) questionnaire. Prescribed doses ranged 28–34 Gy. Median GTV was 2.2 cm(3) (range 1.3–22.9 cm(3)). A gating boundary of 3 mm, and PTV margin of 5 mm around the GTV, were used with auto-beam delivery control. Accuracy of SABR delivery was studied by analyzing delivered MR-cines reconstructed from machine log files. RESULTS: All 10 patients completed the OSS procedure in a single day, and all reported satisfaction with the process. Median time for the treatment planning step and the whole procedure were 2.8 h and 6.6 h, respectively. With optimization of the procedure, treatment could be completed in half a day. During beam-on, the 3 mm tracking boundary encompassed between 78.0 and 100 % of the GTV across all patients, with corresponding PTV values being 94.4–100 % (5th-95th percentiles). On average, system-latency for triggering a beam-off event comprised 5.3 % of the delivery time. Latency reduced GTV coverage by an average of −0.3 %. Duty-cycles during treatment delivery ranged from 26.1 to 64.7 %. CONCLUSIONS: An OSS procedure with MR-guided SABR for lung cancer led to good patient satisfaction. Gated treatment delivery was highly accurate with little impact of system-latency. Elsevier 2022-10-03 /pmc/articles/PMC9547277/ /pubmed/36217429 http://dx.doi.org/10.1016/j.phro.2022.09.010 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research Article
Palacios, Miguel A.
Verheijen, Sonja
Schneiders, Famke L.
Bohoudi, Omar
Slotman, Berend J.
Lagerwaard, Frank J.
Senan, Suresh
Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac
title Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac
title_full Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac
title_fullStr Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac
title_full_unstemmed Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac
title_short Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac
title_sort same-day consultation, simulation and lung stereotactic ablative radiotherapy delivery on a magnetic resonance-linac
topic Original Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9547277/
https://www.ncbi.nlm.nih.gov/pubmed/36217429
http://dx.doi.org/10.1016/j.phro.2022.09.010
work_keys_str_mv AT palaciosmiguela samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac
AT verheijensonja samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac
AT schneidersfamkel samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac
AT bohoudiomar samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac
AT slotmanberendj samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac
AT lagerwaardfrankj samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac
AT senansuresh samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac