Cargando…
Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac
BACKGROUND AND PURPOSE: Magnetic resonance-guided radiotherapy (MRgRT) with real-time intra-fraction tumor motion monitoring allows for high precision Stereotactic Ablative Radiotherapy (SABR). This study aimed to investigate the clinical feasibility, patient satisfaction and delivery accuracy of si...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9547277/ https://www.ncbi.nlm.nih.gov/pubmed/36217429 http://dx.doi.org/10.1016/j.phro.2022.09.010 |
_version_ | 1784805229891420160 |
---|---|
author | Palacios, Miguel A. Verheijen, Sonja Schneiders, Famke L. Bohoudi, Omar Slotman, Berend J. Lagerwaard, Frank J. Senan, Suresh |
author_facet | Palacios, Miguel A. Verheijen, Sonja Schneiders, Famke L. Bohoudi, Omar Slotman, Berend J. Lagerwaard, Frank J. Senan, Suresh |
author_sort | Palacios, Miguel A. |
collection | PubMed |
description | BACKGROUND AND PURPOSE: Magnetic resonance-guided radiotherapy (MRgRT) with real-time intra-fraction tumor motion monitoring allows for high precision Stereotactic Ablative Radiotherapy (SABR). This study aimed to investigate the clinical feasibility, patient satisfaction and delivery accuracy of single-fraction MR-guided SABR in a single day (one-stop-shop, OSS). METHODS AND MATERIALS: Ten patients with small lung tumors eligible for single fraction treatments were included. The OSS procedure consisted of consultation, treatment simulation, treatment planning and delivery. Following SABR delivery, patients completed a reported experience measure (PREM) questionnaire. Prescribed doses ranged 28–34 Gy. Median GTV was 2.2 cm(3) (range 1.3–22.9 cm(3)). A gating boundary of 3 mm, and PTV margin of 5 mm around the GTV, were used with auto-beam delivery control. Accuracy of SABR delivery was studied by analyzing delivered MR-cines reconstructed from machine log files. RESULTS: All 10 patients completed the OSS procedure in a single day, and all reported satisfaction with the process. Median time for the treatment planning step and the whole procedure were 2.8 h and 6.6 h, respectively. With optimization of the procedure, treatment could be completed in half a day. During beam-on, the 3 mm tracking boundary encompassed between 78.0 and 100 % of the GTV across all patients, with corresponding PTV values being 94.4–100 % (5th-95th percentiles). On average, system-latency for triggering a beam-off event comprised 5.3 % of the delivery time. Latency reduced GTV coverage by an average of −0.3 %. Duty-cycles during treatment delivery ranged from 26.1 to 64.7 %. CONCLUSIONS: An OSS procedure with MR-guided SABR for lung cancer led to good patient satisfaction. Gated treatment delivery was highly accurate with little impact of system-latency. |
format | Online Article Text |
id | pubmed-9547277 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-95472772022-10-09 Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac Palacios, Miguel A. Verheijen, Sonja Schneiders, Famke L. Bohoudi, Omar Slotman, Berend J. Lagerwaard, Frank J. Senan, Suresh Phys Imaging Radiat Oncol Original Research Article BACKGROUND AND PURPOSE: Magnetic resonance-guided radiotherapy (MRgRT) with real-time intra-fraction tumor motion monitoring allows for high precision Stereotactic Ablative Radiotherapy (SABR). This study aimed to investigate the clinical feasibility, patient satisfaction and delivery accuracy of single-fraction MR-guided SABR in a single day (one-stop-shop, OSS). METHODS AND MATERIALS: Ten patients with small lung tumors eligible for single fraction treatments were included. The OSS procedure consisted of consultation, treatment simulation, treatment planning and delivery. Following SABR delivery, patients completed a reported experience measure (PREM) questionnaire. Prescribed doses ranged 28–34 Gy. Median GTV was 2.2 cm(3) (range 1.3–22.9 cm(3)). A gating boundary of 3 mm, and PTV margin of 5 mm around the GTV, were used with auto-beam delivery control. Accuracy of SABR delivery was studied by analyzing delivered MR-cines reconstructed from machine log files. RESULTS: All 10 patients completed the OSS procedure in a single day, and all reported satisfaction with the process. Median time for the treatment planning step and the whole procedure were 2.8 h and 6.6 h, respectively. With optimization of the procedure, treatment could be completed in half a day. During beam-on, the 3 mm tracking boundary encompassed between 78.0 and 100 % of the GTV across all patients, with corresponding PTV values being 94.4–100 % (5th-95th percentiles). On average, system-latency for triggering a beam-off event comprised 5.3 % of the delivery time. Latency reduced GTV coverage by an average of −0.3 %. Duty-cycles during treatment delivery ranged from 26.1 to 64.7 %. CONCLUSIONS: An OSS procedure with MR-guided SABR for lung cancer led to good patient satisfaction. Gated treatment delivery was highly accurate with little impact of system-latency. Elsevier 2022-10-03 /pmc/articles/PMC9547277/ /pubmed/36217429 http://dx.doi.org/10.1016/j.phro.2022.09.010 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Research Article Palacios, Miguel A. Verheijen, Sonja Schneiders, Famke L. Bohoudi, Omar Slotman, Berend J. Lagerwaard, Frank J. Senan, Suresh Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac |
title | Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac |
title_full | Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac |
title_fullStr | Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac |
title_full_unstemmed | Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac |
title_short | Same-day consultation, simulation and lung Stereotactic Ablative Radiotherapy delivery on a Magnetic Resonance-linac |
title_sort | same-day consultation, simulation and lung stereotactic ablative radiotherapy delivery on a magnetic resonance-linac |
topic | Original Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9547277/ https://www.ncbi.nlm.nih.gov/pubmed/36217429 http://dx.doi.org/10.1016/j.phro.2022.09.010 |
work_keys_str_mv | AT palaciosmiguela samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac AT verheijensonja samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac AT schneidersfamkel samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac AT bohoudiomar samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac AT slotmanberendj samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac AT lagerwaardfrankj samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac AT senansuresh samedayconsultationsimulationandlungstereotacticablativeradiotherapydeliveryonamagneticresonancelinac |