Paravertebral brachial plexus block in sheep: a cadaveric and in vivo study
The Objective of the present study was to evaluate paravertebral brachial plexus block in sheep. A group of 13 healthy sheep with 20.10 ± 2.20 kg weight and five months of age were used. In phase I, in five sheep, an insulated needle attached to a nerve stimulator was directed to the location of C6,...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Urmia University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9548216/ https://www.ncbi.nlm.nih.gov/pubmed/36320303 http://dx.doi.org/10.30466/vrf.2021.138877.3088 |
_version_ | 1784805396879245312 |
---|---|
author | Imani Rastabi, Hadi Khazaeel, Kaveh Naddaf, Hadi Masroor, Razieh |
author_facet | Imani Rastabi, Hadi Khazaeel, Kaveh Naddaf, Hadi Masroor, Razieh |
author_sort | Imani Rastabi, Hadi |
collection | PubMed |
description | The Objective of the present study was to evaluate paravertebral brachial plexus block in sheep. A group of 13 healthy sheep with 20.10 ± 2.20 kg weight and five months of age were used. In phase I, in five sheep, an insulated needle attached to a nerve stimulator was directed to the location of C6, C7, C8 and T1 nerves and a 1.50 mL of a solution containing 1:1 methylene blue 1.00% and lidocaine 1.00% was injected at each site. Then, the cervical and thoracic areas were dissected and assessed in the cadavers. In phase II, cervical paravertebral block with 2.00% lidocaine and subsequent assessments were done in eight live sheep. Cadaveric evaluations revealed dye spread in C6 to T1 nerves: 61.75 ± 5.50, 72.75 ± 9.18, 40.75 ± 2.99 and 18.75 ± 3.30 mm, respectively. In three sheep, dye distribution in the anterior mediastinum was observed. In phase II, the onsets of anesthesia were determined within 10 and 15 min for sensory and motor blocks, respectively. Anesthesia at axillary, musculocutaneous, radial and ulnar skin sites and motor block lasted for 67.50 ± 15.80, 63.70 ± 16.00, 55.00 ± 21.70, 56.70 ± 19.70 and 76.40 ± 24.30 min, respectively. In three sheep, no anesthesia was observed for radial and ulnar skin sites. In conclusion, paravertebral brachial plexus block in sheep provided an acceptable block for the upper parts of the elbow joint, however, it was not effective and reliable for more distal structures. |
format | Online Article Text |
id | pubmed-9548216 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Urmia University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-95482162022-10-31 Paravertebral brachial plexus block in sheep: a cadaveric and in vivo study Imani Rastabi, Hadi Khazaeel, Kaveh Naddaf, Hadi Masroor, Razieh Vet Res Forum Original Article The Objective of the present study was to evaluate paravertebral brachial plexus block in sheep. A group of 13 healthy sheep with 20.10 ± 2.20 kg weight and five months of age were used. In phase I, in five sheep, an insulated needle attached to a nerve stimulator was directed to the location of C6, C7, C8 and T1 nerves and a 1.50 mL of a solution containing 1:1 methylene blue 1.00% and lidocaine 1.00% was injected at each site. Then, the cervical and thoracic areas were dissected and assessed in the cadavers. In phase II, cervical paravertebral block with 2.00% lidocaine and subsequent assessments were done in eight live sheep. Cadaveric evaluations revealed dye spread in C6 to T1 nerves: 61.75 ± 5.50, 72.75 ± 9.18, 40.75 ± 2.99 and 18.75 ± 3.30 mm, respectively. In three sheep, dye distribution in the anterior mediastinum was observed. In phase II, the onsets of anesthesia were determined within 10 and 15 min for sensory and motor blocks, respectively. Anesthesia at axillary, musculocutaneous, radial and ulnar skin sites and motor block lasted for 67.50 ± 15.80, 63.70 ± 16.00, 55.00 ± 21.70, 56.70 ± 19.70 and 76.40 ± 24.30 min, respectively. In three sheep, no anesthesia was observed for radial and ulnar skin sites. In conclusion, paravertebral brachial plexus block in sheep provided an acceptable block for the upper parts of the elbow joint, however, it was not effective and reliable for more distal structures. Urmia University Press 2022-09 2022-09-15 /pmc/articles/PMC9548216/ /pubmed/36320303 http://dx.doi.org/10.30466/vrf.2021.138877.3088 Text en https://creativecommons.org/licenses/by-nc-sa/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.https://creativecommons.org/licenses/by-nc-sa/4.0/ |
spellingShingle | Original Article Imani Rastabi, Hadi Khazaeel, Kaveh Naddaf, Hadi Masroor, Razieh Paravertebral brachial plexus block in sheep: a cadaveric and in vivo study |
title | Paravertebral brachial plexus block in sheep: a cadaveric and in vivo study |
title_full | Paravertebral brachial plexus block in sheep: a cadaveric and in vivo study |
title_fullStr | Paravertebral brachial plexus block in sheep: a cadaveric and in vivo study |
title_full_unstemmed | Paravertebral brachial plexus block in sheep: a cadaveric and in vivo study |
title_short | Paravertebral brachial plexus block in sheep: a cadaveric and in vivo study |
title_sort | paravertebral brachial plexus block in sheep: a cadaveric and in vivo study |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9548216/ https://www.ncbi.nlm.nih.gov/pubmed/36320303 http://dx.doi.org/10.30466/vrf.2021.138877.3088 |
work_keys_str_mv | AT imanirastabihadi paravertebralbrachialplexusblockinsheepacadavericandinvivostudy AT khazaeelkaveh paravertebralbrachialplexusblockinsheepacadavericandinvivostudy AT naddafhadi paravertebralbrachialplexusblockinsheepacadavericandinvivostudy AT masroorrazieh paravertebralbrachialplexusblockinsheepacadavericandinvivostudy |