Cargando…
Pulsed-wave Doppler ultrasonographical measurements of supra-mammary lymph nodes for diagnosis of bovine mastitis
The aim of this study was to investigate the relationship between mastitis and supra-mammary lymph nodes in lactating cows in terms of Pulsed-wave (PW) Doppler ultrasonographical measurements. A total of 102 head cows in lactation period were divided into three groups. The cows in which all mammary...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Urmia University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9548227/ https://www.ncbi.nlm.nih.gov/pubmed/36320312 http://dx.doi.org/10.30466/vrf.2020.124958.2925 |
_version_ | 1784805399678943232 |
---|---|
author | Rişvanli, Ali Dogan, Halef Safak, Tarik Kilic, Mehmet Akif Seker, Ibrahim |
author_facet | Rişvanli, Ali Dogan, Halef Safak, Tarik Kilic, Mehmet Akif Seker, Ibrahim |
author_sort | Rişvanli, Ali |
collection | PubMed |
description | The aim of this study was to investigate the relationship between mastitis and supra-mammary lymph nodes in lactating cows in terms of Pulsed-wave (PW) Doppler ultrasonographical measurements. A total of 102 head cows in lactation period were divided into three groups. The cows in which all mammary lobes were California mastitis test (CMT)-negative (n = 27) formed the 1(st) group; those with CMT-positive mammary lobe (n = 43) formed the 2(nd) group and the cows with clinical mastitis in at least one mammary lobe (n = 32) formed the 3(rd) group. In PW Doppler ultrasonography, end-diastolic velocity, systolic peak velocity and time-averaged maximum velocity were measured at the most prominent artery of the lymph node. A quantitative scaling was performed by determining the pulsatile index and resistance index scales based on blood flow parameters. There was no statistically significant difference between the study groups in terms of PW Doppler ultrasonographical measurements of supra-mammary lymph nodes. In conclusion, the use of PW Doppler ultrasonographic data of the supra-mammary lymph nodes will not provide useful information about the current condition of mastitis in cows. |
format | Online Article Text |
id | pubmed-9548227 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Urmia University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-95482272022-10-31 Pulsed-wave Doppler ultrasonographical measurements of supra-mammary lymph nodes for diagnosis of bovine mastitis Rişvanli, Ali Dogan, Halef Safak, Tarik Kilic, Mehmet Akif Seker, Ibrahim Vet Res Forum Short Communication The aim of this study was to investigate the relationship between mastitis and supra-mammary lymph nodes in lactating cows in terms of Pulsed-wave (PW) Doppler ultrasonographical measurements. A total of 102 head cows in lactation period were divided into three groups. The cows in which all mammary lobes were California mastitis test (CMT)-negative (n = 27) formed the 1(st) group; those with CMT-positive mammary lobe (n = 43) formed the 2(nd) group and the cows with clinical mastitis in at least one mammary lobe (n = 32) formed the 3(rd) group. In PW Doppler ultrasonography, end-diastolic velocity, systolic peak velocity and time-averaged maximum velocity were measured at the most prominent artery of the lymph node. A quantitative scaling was performed by determining the pulsatile index and resistance index scales based on blood flow parameters. There was no statistically significant difference between the study groups in terms of PW Doppler ultrasonographical measurements of supra-mammary lymph nodes. In conclusion, the use of PW Doppler ultrasonographic data of the supra-mammary lymph nodes will not provide useful information about the current condition of mastitis in cows. Urmia University Press 2022-09 2022-09-15 /pmc/articles/PMC9548227/ /pubmed/36320312 http://dx.doi.org/10.30466/vrf.2020.124958.2925 Text en https://creativecommons.org/licenses/by-nc-sa/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.https://creativecommons.org/licenses/by-nc-sa/4.0/ |
spellingShingle | Short Communication Rişvanli, Ali Dogan, Halef Safak, Tarik Kilic, Mehmet Akif Seker, Ibrahim Pulsed-wave Doppler ultrasonographical measurements of supra-mammary lymph nodes for diagnosis of bovine mastitis |
title | Pulsed-wave Doppler ultrasonographical measurements of supra-mammary lymph nodes for diagnosis of bovine mastitis |
title_full | Pulsed-wave Doppler ultrasonographical measurements of supra-mammary lymph nodes for diagnosis of bovine mastitis |
title_fullStr | Pulsed-wave Doppler ultrasonographical measurements of supra-mammary lymph nodes for diagnosis of bovine mastitis |
title_full_unstemmed | Pulsed-wave Doppler ultrasonographical measurements of supra-mammary lymph nodes for diagnosis of bovine mastitis |
title_short | Pulsed-wave Doppler ultrasonographical measurements of supra-mammary lymph nodes for diagnosis of bovine mastitis |
title_sort | pulsed-wave doppler ultrasonographical measurements of supra-mammary lymph nodes for diagnosis of bovine mastitis |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9548227/ https://www.ncbi.nlm.nih.gov/pubmed/36320312 http://dx.doi.org/10.30466/vrf.2020.124958.2925 |
work_keys_str_mv | AT risvanliali pulsedwavedopplerultrasonographicalmeasurementsofsupramammarylymphnodesfordiagnosisofbovinemastitis AT doganhalef pulsedwavedopplerultrasonographicalmeasurementsofsupramammarylymphnodesfordiagnosisofbovinemastitis AT safaktarik pulsedwavedopplerultrasonographicalmeasurementsofsupramammarylymphnodesfordiagnosisofbovinemastitis AT kilicmehmetakif pulsedwavedopplerultrasonographicalmeasurementsofsupramammarylymphnodesfordiagnosisofbovinemastitis AT sekeribrahim pulsedwavedopplerultrasonographicalmeasurementsofsupramammarylymphnodesfordiagnosisofbovinemastitis |