Cargando…

Instrument referral criteria for PlusoptiX and SureSight based on 2021 AAPOS guidelines: A population-based study

OBJECTIVE: The study aims to assess two refractive instrument-based methods of vision screening (SureSight and PlusoptiX) to detect refractive amblyopia risk factors (ARFs) and significant refractive errors in Chinese preschool children and to develop referral criteria according to the 2021 AAPOS gu...

Descripción completa

Detalles Bibliográficos
Autores principales: Yan, Qi, Li, Rui, Qian, YingXiao, Lin, Xiao, Zhu, Hui, Wang, Yue, Zhao, Xiaoyan, Zhang, Xiaohan, Sun, Qigang, Hao, Qingfeng, Tong, Haohai, Zhu, Yue, Li, Zhitong, Zhu, Yan, Liu, Hu, Huang, Dan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9548965/
https://www.ncbi.nlm.nih.gov/pubmed/36225773
http://dx.doi.org/10.3389/fpubh.2022.959757
_version_ 1784805557822029824
author Yan, Qi
Li, Rui
Qian, YingXiao
Lin, Xiao
Zhu, Hui
Wang, Yue
Zhao, Xiaoyan
Zhang, Xiaohan
Sun, Qigang
Hao, Qingfeng
Tong, Haohai
Zhu, Yue
Li, Zhitong
Zhu, Yan
Liu, Hu
Huang, Dan
author_facet Yan, Qi
Li, Rui
Qian, YingXiao
Lin, Xiao
Zhu, Hui
Wang, Yue
Zhao, Xiaoyan
Zhang, Xiaohan
Sun, Qigang
Hao, Qingfeng
Tong, Haohai
Zhu, Yue
Li, Zhitong
Zhu, Yan
Liu, Hu
Huang, Dan
author_sort Yan, Qi
collection PubMed
description OBJECTIVE: The study aims to assess two refractive instrument-based methods of vision screening (SureSight and PlusoptiX) to detect refractive amblyopia risk factors (ARFs) and significant refractive errors in Chinese preschool children and to develop referral criteria according to the 2021 AAPOS guidelines. METHODS: Eye examinations were conducted in children aged 61 to 72 months (n = 1,173) using a PlusoptiX photoscreener, SureSight autorefractor, and cycloplegic retinoscopy (CR). The Vision Screening Committee of AAPOS's preschool vision screening guidelines from 2021 were adopted for comparison. Paired t-test analysis and Bland–Altman plots were used to assess the differences and agreement between the PlusoptiX photoscreener, SureSight autorefractor, and CR. In addition, the validity of the cut-off values of the several ARFs measured with the SureSight and PlusoptiX was estimated using receiver operating characteristic (ROC) curves and compared to the age-based 2021 AAPOS examination failure levels. RESULTS: A total of 1,173 children were tested with comprehensive eye examinations. When the referral numbers based on the 2013 (43/3.67%) and 2021 (42/3.58%) AAPOS guidelines were compared, significant differences between the values of astigmatism (72.09 vs. 52.38%) and anisometropia (11.63 vs. 38.10%) were found. The 95% limits of agreement (LOA) of the spherical value and the cylindrical value between PlusoptiX and CR were 95.08 and 96.29%. It was 93.87 and 98.10% between SureSight and CR. Considering refractive failure levels, the ROC curves obtained the optimal cut-off points. However, the PlusoptiX and the SureSight showed lower efficiency in hyperopia (Youden index, 0.60 vs. 0.83) and myopia (Youden index, 078 vs. 0.93), respectively. After adjusting the above cut-off points, the optimized NES (Nanjing Eye Study) referral criteria for myopia, hyperopia, astigmatism, and anisometropia were –0.75, 1.25, –1.0, and 0.5 with PlusoptiX and –1.25, 2.75, –1.5, and 0.75 with SureSight. CONCLUSIONS: SureSight and PlusoptiX showed a good correlation with CR and could effectively detect refractive ARFs and visually significant refractive errors. There were obvious advantages in detecting hyperopia using SureSight and myopia using PlusoptiX. We proposed instrumental referral criteria for age-based preschool children based on AAPOS 2021 guidelines.
format Online
Article
Text
id pubmed-9548965
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-95489652022-10-11 Instrument referral criteria for PlusoptiX and SureSight based on 2021 AAPOS guidelines: A population-based study Yan, Qi Li, Rui Qian, YingXiao Lin, Xiao Zhu, Hui Wang, Yue Zhao, Xiaoyan Zhang, Xiaohan Sun, Qigang Hao, Qingfeng Tong, Haohai Zhu, Yue Li, Zhitong Zhu, Yan Liu, Hu Huang, Dan Front Public Health Public Health OBJECTIVE: The study aims to assess two refractive instrument-based methods of vision screening (SureSight and PlusoptiX) to detect refractive amblyopia risk factors (ARFs) and significant refractive errors in Chinese preschool children and to develop referral criteria according to the 2021 AAPOS guidelines. METHODS: Eye examinations were conducted in children aged 61 to 72 months (n = 1,173) using a PlusoptiX photoscreener, SureSight autorefractor, and cycloplegic retinoscopy (CR). The Vision Screening Committee of AAPOS's preschool vision screening guidelines from 2021 were adopted for comparison. Paired t-test analysis and Bland–Altman plots were used to assess the differences and agreement between the PlusoptiX photoscreener, SureSight autorefractor, and CR. In addition, the validity of the cut-off values of the several ARFs measured with the SureSight and PlusoptiX was estimated using receiver operating characteristic (ROC) curves and compared to the age-based 2021 AAPOS examination failure levels. RESULTS: A total of 1,173 children were tested with comprehensive eye examinations. When the referral numbers based on the 2013 (43/3.67%) and 2021 (42/3.58%) AAPOS guidelines were compared, significant differences between the values of astigmatism (72.09 vs. 52.38%) and anisometropia (11.63 vs. 38.10%) were found. The 95% limits of agreement (LOA) of the spherical value and the cylindrical value between PlusoptiX and CR were 95.08 and 96.29%. It was 93.87 and 98.10% between SureSight and CR. Considering refractive failure levels, the ROC curves obtained the optimal cut-off points. However, the PlusoptiX and the SureSight showed lower efficiency in hyperopia (Youden index, 0.60 vs. 0.83) and myopia (Youden index, 078 vs. 0.93), respectively. After adjusting the above cut-off points, the optimized NES (Nanjing Eye Study) referral criteria for myopia, hyperopia, astigmatism, and anisometropia were –0.75, 1.25, –1.0, and 0.5 with PlusoptiX and –1.25, 2.75, –1.5, and 0.75 with SureSight. CONCLUSIONS: SureSight and PlusoptiX showed a good correlation with CR and could effectively detect refractive ARFs and visually significant refractive errors. There were obvious advantages in detecting hyperopia using SureSight and myopia using PlusoptiX. We proposed instrumental referral criteria for age-based preschool children based on AAPOS 2021 guidelines. Frontiers Media S.A. 2022-09-26 /pmc/articles/PMC9548965/ /pubmed/36225773 http://dx.doi.org/10.3389/fpubh.2022.959757 Text en Copyright © 2022 Yan, Li, Qian, Lin, Zhu, Wang, Zhao, Zhang, Sun, Hao, Tong, Zhu, Li, Zhu, Liu and Huang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Public Health
Yan, Qi
Li, Rui
Qian, YingXiao
Lin, Xiao
Zhu, Hui
Wang, Yue
Zhao, Xiaoyan
Zhang, Xiaohan
Sun, Qigang
Hao, Qingfeng
Tong, Haohai
Zhu, Yue
Li, Zhitong
Zhu, Yan
Liu, Hu
Huang, Dan
Instrument referral criteria for PlusoptiX and SureSight based on 2021 AAPOS guidelines: A population-based study
title Instrument referral criteria for PlusoptiX and SureSight based on 2021 AAPOS guidelines: A population-based study
title_full Instrument referral criteria for PlusoptiX and SureSight based on 2021 AAPOS guidelines: A population-based study
title_fullStr Instrument referral criteria for PlusoptiX and SureSight based on 2021 AAPOS guidelines: A population-based study
title_full_unstemmed Instrument referral criteria for PlusoptiX and SureSight based on 2021 AAPOS guidelines: A population-based study
title_short Instrument referral criteria for PlusoptiX and SureSight based on 2021 AAPOS guidelines: A population-based study
title_sort instrument referral criteria for plusoptix and suresight based on 2021 aapos guidelines: a population-based study
topic Public Health
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9548965/
https://www.ncbi.nlm.nih.gov/pubmed/36225773
http://dx.doi.org/10.3389/fpubh.2022.959757
work_keys_str_mv AT yanqi instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT lirui instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT qianyingxiao instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT linxiao instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT zhuhui instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT wangyue instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT zhaoxiaoyan instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT zhangxiaohan instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT sunqigang instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT haoqingfeng instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT tonghaohai instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT zhuyue instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT lizhitong instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT zhuyan instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT liuhu instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy
AT huangdan instrumentreferralcriteriaforplusoptixandsuresightbasedon2021aaposguidelinesapopulationbasedstudy