Cargando…

Comparison of different correction formulas and measurement methods for the accurate determination of intraocular pressure after SMILE and FS-LASIK surgery

BACKGROUND: To compare the accuracy of non-contact tonometry, Pentacam, and corneal visualization Scheimpflug technology (Corvis ST) for the measurement of intraocular pressure (IOP) after small incision lenticule extraction (SMILE) or femtosecond laser-assisted in situ keratomileusis (FS-LASIK) sur...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Zhiqing, Miao, Na, Wang, Lixiang, Ma, Ke
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9549448/
https://www.ncbi.nlm.nih.gov/pubmed/36217120
http://dx.doi.org/10.1186/s12886-022-02620-7
Descripción
Sumario:BACKGROUND: To compare the accuracy of non-contact tonometry, Pentacam, and corneal visualization Scheimpflug technology (Corvis ST) for the measurement of intraocular pressure (IOP) after small incision lenticule extraction (SMILE) or femtosecond laser-assisted in situ keratomileusis (FS-LASIK) surgery. METHODS: A total of 49 patients (98 eyes) undergoing FS-LASIK or SMILE surgery at West China Hospital, Sichuan University from January to March 2021 were enrolled in this prospective, comparative, self-controlled study. IOP values were measured with non-contact tonometer, Pentacam, and Corvis ST before surgery and 1 month after surgery. Pentacam-derived postoperative IOP values were corrected using five correction formulas (Ehlers, Shah, Dresden, Orssengo-Pye, and Kohlhaas), while Corvis ST-derived values were corrected using a single formula. RESULTS: In the SMILE group, no significant differences were observed between the IOP values corrected with the Shah formula before and after surgery (t = 0.17, P = 0.869), whereas postoperative IOP values corrected with the other formulas were significantly different from the corresponding preoperative measurements (P < 0.05). In the FS-LASIK group, postoperative IOP values corrected with the Ehlers, Shah, or Corvis ST formulas were significantly different from the corresponding preoperative IOP measurements (P < 0.05), but no significant differences were observed between pre- and postoperative IOP values corrected with the Dresden (t =  − 0.08, P = 0.941), Orssengo-Pye (t =  − 0.52, P = 0.604), or Kohlhaas (t = 1.22, P = 0.231) formulas. CONCLUSIONS: Pentacam’s Shah correction formula seemed to be the most appropriate method for accurately measuring postoperative IOP in patients undergoing SMILE surgery, while the Dresden, Orssengo-Pye, and Kohlhaas correction formulas of Pentacam were identified as the most reliable methods for estimating IOP in patients after FS-LASIK surgery. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-022-02620-7.