Cargando…
Different tibial rotational axes can be applied in combination according to the tibial tuberosity–posterior cruciate ligament distance in total knee arthroplasty
PURPOSE: The purpose of this study was to investigate whether tibial tuberosity–posterior cruciate ligament (TT-PCL) distance is representative of the true lateralization of tibial tuberosity in isolation and its influence on the accuracy of the Akagi line and medial third of the tibial tuberosity (...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9549616/ https://www.ncbi.nlm.nih.gov/pubmed/36217137 http://dx.doi.org/10.1186/s12891-022-05859-9 |
_version_ | 1784805712404152320 |
---|---|
author | Zhang, Le-Shu Zhou, Hang Zhang, Jin-Cheng Zhang, Qiang Chen, Xiang-Yang Feng, Shuo |
author_facet | Zhang, Le-Shu Zhou, Hang Zhang, Jin-Cheng Zhang, Qiang Chen, Xiang-Yang Feng, Shuo |
author_sort | Zhang, Le-Shu |
collection | PubMed |
description | PURPOSE: The purpose of this study was to investigate whether tibial tuberosity–posterior cruciate ligament (TT-PCL) distance is representative of the true lateralization of tibial tuberosity in isolation and its influence on the accuracy of the Akagi line and medial third of the tibial tuberosity (MTTT). METHODS: A total of 135 osteoarthritis patients with varus knees who undergoing computed tomography scans were enrolled to establish three-dimension models of the knees. Tibial width (TW), tibial tuberosity lateralization (TTL), posterior cruciate ligament lateralization (PCLL), knee rotation angle (KRA) and tibial rotational axes were measured and investigated their correlations with TT-PCL distance. Based on the analysis of receiver operating characteristic (ROC) curve, the influence of TT-PCL distance on the distributions of mismatch angles of tibial rotational axes was investigated with a safe zone (-5° to 10°). RESULTS: TT-PCL distance was in significantly positive correlation with TW (r = 0.493; P < 0.001) and TTL (r = 0.378; P < 0.001) which was different with PCLL (r = 0.147; P = 0.009) and KRA (r = -0.166; P = 0.054). All tibial rotational axes were significantly positively correlated with TT-PCL distance (P < 0.001). The mismatch angles between the vertical line of the surgical epicondylar axis (SEA) and the Akagi line and MTTT were -1.7° ± 5.3° and 7.6° ± 5.6° respectively. In terms of the optimal cut-off value of 19 mm for TT-PCL distance, the Akagi line applied as tibial rotational axis ensures 87.3% of the positions of tibial components within the safe zone when TT-PCL distance > 19 mm, and MTTT ensures 83.3% when TT-PCL distance ≤ 19 mm. CONCLUSION: TT-PCL distances cannot reflect the true lateralization of tibial tuberosity in isolation but can aid in the combination of the Akagi line and MTTT in varus knees. The patients with TT-PCL distance > 19 mm are recommended to reference the Akagi line for tibial rotational alignment. MTTT is recommended to the patients with TT-PCL distance ≤ 19 mm. The study will aid surgeons in deciding which reference may be used by measuring TT-PCL distance using a preoperative CT. |
format | Online Article Text |
id | pubmed-9549616 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-95496162022-10-11 Different tibial rotational axes can be applied in combination according to the tibial tuberosity–posterior cruciate ligament distance in total knee arthroplasty Zhang, Le-Shu Zhou, Hang Zhang, Jin-Cheng Zhang, Qiang Chen, Xiang-Yang Feng, Shuo BMC Musculoskelet Disord Research PURPOSE: The purpose of this study was to investigate whether tibial tuberosity–posterior cruciate ligament (TT-PCL) distance is representative of the true lateralization of tibial tuberosity in isolation and its influence on the accuracy of the Akagi line and medial third of the tibial tuberosity (MTTT). METHODS: A total of 135 osteoarthritis patients with varus knees who undergoing computed tomography scans were enrolled to establish three-dimension models of the knees. Tibial width (TW), tibial tuberosity lateralization (TTL), posterior cruciate ligament lateralization (PCLL), knee rotation angle (KRA) and tibial rotational axes were measured and investigated their correlations with TT-PCL distance. Based on the analysis of receiver operating characteristic (ROC) curve, the influence of TT-PCL distance on the distributions of mismatch angles of tibial rotational axes was investigated with a safe zone (-5° to 10°). RESULTS: TT-PCL distance was in significantly positive correlation with TW (r = 0.493; P < 0.001) and TTL (r = 0.378; P < 0.001) which was different with PCLL (r = 0.147; P = 0.009) and KRA (r = -0.166; P = 0.054). All tibial rotational axes were significantly positively correlated with TT-PCL distance (P < 0.001). The mismatch angles between the vertical line of the surgical epicondylar axis (SEA) and the Akagi line and MTTT were -1.7° ± 5.3° and 7.6° ± 5.6° respectively. In terms of the optimal cut-off value of 19 mm for TT-PCL distance, the Akagi line applied as tibial rotational axis ensures 87.3% of the positions of tibial components within the safe zone when TT-PCL distance > 19 mm, and MTTT ensures 83.3% when TT-PCL distance ≤ 19 mm. CONCLUSION: TT-PCL distances cannot reflect the true lateralization of tibial tuberosity in isolation but can aid in the combination of the Akagi line and MTTT in varus knees. The patients with TT-PCL distance > 19 mm are recommended to reference the Akagi line for tibial rotational alignment. MTTT is recommended to the patients with TT-PCL distance ≤ 19 mm. The study will aid surgeons in deciding which reference may be used by measuring TT-PCL distance using a preoperative CT. BioMed Central 2022-10-10 /pmc/articles/PMC9549616/ /pubmed/36217137 http://dx.doi.org/10.1186/s12891-022-05859-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Zhang, Le-Shu Zhou, Hang Zhang, Jin-Cheng Zhang, Qiang Chen, Xiang-Yang Feng, Shuo Different tibial rotational axes can be applied in combination according to the tibial tuberosity–posterior cruciate ligament distance in total knee arthroplasty |
title | Different tibial rotational axes can be applied in combination according to the tibial tuberosity–posterior cruciate ligament distance in total knee arthroplasty |
title_full | Different tibial rotational axes can be applied in combination according to the tibial tuberosity–posterior cruciate ligament distance in total knee arthroplasty |
title_fullStr | Different tibial rotational axes can be applied in combination according to the tibial tuberosity–posterior cruciate ligament distance in total knee arthroplasty |
title_full_unstemmed | Different tibial rotational axes can be applied in combination according to the tibial tuberosity–posterior cruciate ligament distance in total knee arthroplasty |
title_short | Different tibial rotational axes can be applied in combination according to the tibial tuberosity–posterior cruciate ligament distance in total knee arthroplasty |
title_sort | different tibial rotational axes can be applied in combination according to the tibial tuberosity–posterior cruciate ligament distance in total knee arthroplasty |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9549616/ https://www.ncbi.nlm.nih.gov/pubmed/36217137 http://dx.doi.org/10.1186/s12891-022-05859-9 |
work_keys_str_mv | AT zhangleshu differenttibialrotationalaxescanbeappliedincombinationaccordingtothetibialtuberosityposteriorcruciateligamentdistanceintotalkneearthroplasty AT zhouhang differenttibialrotationalaxescanbeappliedincombinationaccordingtothetibialtuberosityposteriorcruciateligamentdistanceintotalkneearthroplasty AT zhangjincheng differenttibialrotationalaxescanbeappliedincombinationaccordingtothetibialtuberosityposteriorcruciateligamentdistanceintotalkneearthroplasty AT zhangqiang differenttibialrotationalaxescanbeappliedincombinationaccordingtothetibialtuberosityposteriorcruciateligamentdistanceintotalkneearthroplasty AT chenxiangyang differenttibialrotationalaxescanbeappliedincombinationaccordingtothetibialtuberosityposteriorcruciateligamentdistanceintotalkneearthroplasty AT fengshuo differenttibialrotationalaxescanbeappliedincombinationaccordingtothetibialtuberosityposteriorcruciateligamentdistanceintotalkneearthroplasty |