Cargando…
Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest
Many studies have reported indications and complications of surgical stabilization of rib fractures. However, data about the postoperative complications after the removal of the plates are still lacking. The author reports a rare complication after plate removal, postoperative submuscular emphysema,...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9550354/ https://www.ncbi.nlm.nih.gov/pubmed/36226137 http://dx.doi.org/10.1093/jscr/rjac459 |
_version_ | 1784805864133099520 |
---|---|
author | Seok, Junepill |
author_facet | Seok, Junepill |
author_sort | Seok, Junepill |
collection | PubMed |
description | Many studies have reported indications and complications of surgical stabilization of rib fractures. However, data about the postoperative complications after the removal of the plates are still lacking. The author reports a rare complication after plate removal, postoperative submuscular emphysema, due to air leakage from the residual screw hole. A 68-year-old male with a flail chest was successfully treated by surgical rib fixation. A few months later, the patient wanted his implants removed due to chest irritation. The removal operation was completed, and postoperative courses were not unusual. However, a large amount of submuscular emphysema was found in the follow-up period. The patient was successfully managed by applying a submuscular thoracic drainage catheter. Although postoperative subcutaneous emphysema due to residual screw holes after plate removal is rare, we need to pay more attention when selecting the proper length of screws during surgical rib fixation. |
format | Online Article Text |
id | pubmed-9550354 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-95503542022-10-11 Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest Seok, Junepill J Surg Case Rep Case Report Many studies have reported indications and complications of surgical stabilization of rib fractures. However, data about the postoperative complications after the removal of the plates are still lacking. The author reports a rare complication after plate removal, postoperative submuscular emphysema, due to air leakage from the residual screw hole. A 68-year-old male with a flail chest was successfully treated by surgical rib fixation. A few months later, the patient wanted his implants removed due to chest irritation. The removal operation was completed, and postoperative courses were not unusual. However, a large amount of submuscular emphysema was found in the follow-up period. The patient was successfully managed by applying a submuscular thoracic drainage catheter. Although postoperative subcutaneous emphysema due to residual screw holes after plate removal is rare, we need to pay more attention when selecting the proper length of screws during surgical rib fixation. Oxford University Press 2022-10-10 /pmc/articles/PMC9550354/ /pubmed/36226137 http://dx.doi.org/10.1093/jscr/rjac459 Text en Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author(s) 2022. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Case Report Seok, Junepill Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest |
title | Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest |
title_full | Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest |
title_fullStr | Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest |
title_full_unstemmed | Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest |
title_short | Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest |
title_sort | postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9550354/ https://www.ncbi.nlm.nih.gov/pubmed/36226137 http://dx.doi.org/10.1093/jscr/rjac459 |
work_keys_str_mv | AT seokjunepill postoperativesubmuscularemphysemaduetoairleakagefromtheresidualscrewholesafterplateremovalinapatientwhohadundergonesurgicalstabilizationofflailchest |