Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest

Many studies have reported indications and complications of surgical stabilization of rib fractures. However, data about the postoperative complications after the removal of the plates are still lacking. The author reports a rare complication after plate removal, postoperative submuscular emphysema,...

Descripción completa

Detalles Bibliográficos
Autor principal: Seok, Junepill
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9550354/
https://www.ncbi.nlm.nih.gov/pubmed/36226137
http://dx.doi.org/10.1093/jscr/rjac459
_version_ 1784805864133099520
author Seok, Junepill
author_facet Seok, Junepill
author_sort Seok, Junepill
collection PubMed
description Many studies have reported indications and complications of surgical stabilization of rib fractures. However, data about the postoperative complications after the removal of the plates are still lacking. The author reports a rare complication after plate removal, postoperative submuscular emphysema, due to air leakage from the residual screw hole. A 68-year-old male with a flail chest was successfully treated by surgical rib fixation. A few months later, the patient wanted his implants removed due to chest irritation. The removal operation was completed, and postoperative courses were not unusual. However, a large amount of submuscular emphysema was found in the follow-up period. The patient was successfully managed by applying a submuscular thoracic drainage catheter. Although postoperative subcutaneous emphysema due to residual screw holes after plate removal is rare, we need to pay more attention when selecting the proper length of screws during surgical rib fixation.
format Online
Article
Text
id pubmed-9550354
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-95503542022-10-11 Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest Seok, Junepill J Surg Case Rep Case Report Many studies have reported indications and complications of surgical stabilization of rib fractures. However, data about the postoperative complications after the removal of the plates are still lacking. The author reports a rare complication after plate removal, postoperative submuscular emphysema, due to air leakage from the residual screw hole. A 68-year-old male with a flail chest was successfully treated by surgical rib fixation. A few months later, the patient wanted his implants removed due to chest irritation. The removal operation was completed, and postoperative courses were not unusual. However, a large amount of submuscular emphysema was found in the follow-up period. The patient was successfully managed by applying a submuscular thoracic drainage catheter. Although postoperative subcutaneous emphysema due to residual screw holes after plate removal is rare, we need to pay more attention when selecting the proper length of screws during surgical rib fixation. Oxford University Press 2022-10-10 /pmc/articles/PMC9550354/ /pubmed/36226137 http://dx.doi.org/10.1093/jscr/rjac459 Text en Published by Oxford University Press and JSCR Publishing Ltd. All rights reserved. © The Author(s) 2022. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Report
Seok, Junepill
Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest
title Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest
title_full Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest
title_fullStr Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest
title_full_unstemmed Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest
title_short Postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest
title_sort postoperative submuscular emphysema due to air leakage from the residual screw holes after plate removal in a patient who had undergone surgical stabilization of flail chest
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9550354/
https://www.ncbi.nlm.nih.gov/pubmed/36226137
http://dx.doi.org/10.1093/jscr/rjac459
work_keys_str_mv AT seokjunepill postoperativesubmuscularemphysemaduetoairleakagefromtheresidualscrewholesafterplateremovalinapatientwhohadundergonesurgicalstabilizationofflailchest