Cargando…
Radiation Exposure of Interventional Radiologists during Computed Tomography Fluoroscopy-Guided Percutaneous Cryoablation
PURPOSE: The principal aim of this study was to evaluate radiation exposure of interventionalists during computed tomography (CT) fluoroscopy-guided percutaneous cryoablation (PCA) using radiophotoluminescent glass dosimeters (RPLDs). The radioprotective effects of safety glasses and lead apron were...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Japanese Society of Interventional Radiology
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9550382/ https://www.ncbi.nlm.nih.gov/pubmed/36284661 http://dx.doi.org/10.22575/interventionalradiology.2019-0009 |
_version_ | 1784805871716401152 |
---|---|
author | Seki, Yuko Miyazaki, Masaya Fukushima, Yasuhiro Ando, Masashi Tsushima, Yoshito |
author_facet | Seki, Yuko Miyazaki, Masaya Fukushima, Yasuhiro Ando, Masashi Tsushima, Yoshito |
author_sort | Seki, Yuko |
collection | PubMed |
description | PURPOSE: The principal aim of this study was to evaluate radiation exposure of interventionalists during computed tomography (CT) fluoroscopy-guided percutaneous cryoablation (PCA) using radiophotoluminescent glass dosimeters (RPLDs). The radioprotective effects of safety glasses and lead apron were also evaluated. MATERIALS AND METHODS: Radiation exposure of interventionalists during 46 CT fluoroscopy-guided PCA procedures was evaluated. Entrance surface dose (ESD) was measured using RPLDs on multiple sites: five sites, representing eye lens exposure; five sites, representing body exposure; and four sites, representing skin exposure. The ESD values on multiple sites were compared between different PCA procedures (renal, liver, and bone). RESULTS: The mean ESD on the X-ray-side hand exhibited the highest value (358.8 μGy). Regarding evaluation sites representing exposure to the eye lens, the highest ESD inside the radiation protective glasses was detected on the X-ray-side cheek (167.1 μGy). Most ESD values among multiple sites (10/14) were linearly correlated with CT fluoroscopy time. Among them, the ESD values measured during renal and liver PCA were relatively higher than those measured during bone PCA, especially on the chest area outside the lead apron, and on the X-ray tube-side elbow and hand during renal and bone PCA. Radioprotective effects of safety glasses and lead apron ranged from 44.6 to 50.6% and from 30.2 to 79.6%, respectively, on each evaluation site. CONCLUSION: The site with the highest radiation exposure on interventionalists during CT fluoroscopy-guided PCA was the X-ray tube-side hand. Radiation exposure of interventionalists was at acceptable levels and consistent with the recommended dose limits. |
format | Online Article Text |
id | pubmed-9550382 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Japanese Society of Interventional Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-95503822022-10-24 Radiation Exposure of Interventional Radiologists during Computed Tomography Fluoroscopy-Guided Percutaneous Cryoablation Seki, Yuko Miyazaki, Masaya Fukushima, Yasuhiro Ando, Masashi Tsushima, Yoshito Interv Radiol (Higashimatsuyama) Original Research PURPOSE: The principal aim of this study was to evaluate radiation exposure of interventionalists during computed tomography (CT) fluoroscopy-guided percutaneous cryoablation (PCA) using radiophotoluminescent glass dosimeters (RPLDs). The radioprotective effects of safety glasses and lead apron were also evaluated. MATERIALS AND METHODS: Radiation exposure of interventionalists during 46 CT fluoroscopy-guided PCA procedures was evaluated. Entrance surface dose (ESD) was measured using RPLDs on multiple sites: five sites, representing eye lens exposure; five sites, representing body exposure; and four sites, representing skin exposure. The ESD values on multiple sites were compared between different PCA procedures (renal, liver, and bone). RESULTS: The mean ESD on the X-ray-side hand exhibited the highest value (358.8 μGy). Regarding evaluation sites representing exposure to the eye lens, the highest ESD inside the radiation protective glasses was detected on the X-ray-side cheek (167.1 μGy). Most ESD values among multiple sites (10/14) were linearly correlated with CT fluoroscopy time. Among them, the ESD values measured during renal and liver PCA were relatively higher than those measured during bone PCA, especially on the chest area outside the lead apron, and on the X-ray tube-side elbow and hand during renal and bone PCA. Radioprotective effects of safety glasses and lead apron ranged from 44.6 to 50.6% and from 30.2 to 79.6%, respectively, on each evaluation site. CONCLUSION: The site with the highest radiation exposure on interventionalists during CT fluoroscopy-guided PCA was the X-ray tube-side hand. Radiation exposure of interventionalists was at acceptable levels and consistent with the recommended dose limits. The Japanese Society of Interventional Radiology 2020-05-14 /pmc/articles/PMC9550382/ /pubmed/36284661 http://dx.doi.org/10.22575/interventionalradiology.2019-0009 Text en © 2020 Japanese Society of Interventional Radiology https://creativecommons.org/licenses/by-nc/4.0/Interventional Radiology is an Open Access journal distributed under the Creative Commons Attribution-NonCommercial 4.0 International License. To view the details of this license, please visit (https://creativecommons.org/licenses/by-nc/4.0/). |
spellingShingle | Original Research Seki, Yuko Miyazaki, Masaya Fukushima, Yasuhiro Ando, Masashi Tsushima, Yoshito Radiation Exposure of Interventional Radiologists during Computed Tomography Fluoroscopy-Guided Percutaneous Cryoablation |
title | Radiation Exposure of Interventional Radiologists during Computed Tomography Fluoroscopy-Guided Percutaneous Cryoablation |
title_full | Radiation Exposure of Interventional Radiologists during Computed Tomography Fluoroscopy-Guided Percutaneous Cryoablation |
title_fullStr | Radiation Exposure of Interventional Radiologists during Computed Tomography Fluoroscopy-Guided Percutaneous Cryoablation |
title_full_unstemmed | Radiation Exposure of Interventional Radiologists during Computed Tomography Fluoroscopy-Guided Percutaneous Cryoablation |
title_short | Radiation Exposure of Interventional Radiologists during Computed Tomography Fluoroscopy-Guided Percutaneous Cryoablation |
title_sort | radiation exposure of interventional radiologists during computed tomography fluoroscopy-guided percutaneous cryoablation |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9550382/ https://www.ncbi.nlm.nih.gov/pubmed/36284661 http://dx.doi.org/10.22575/interventionalradiology.2019-0009 |
work_keys_str_mv | AT sekiyuko radiationexposureofinterventionalradiologistsduringcomputedtomographyfluoroscopyguidedpercutaneouscryoablation AT miyazakimasaya radiationexposureofinterventionalradiologistsduringcomputedtomographyfluoroscopyguidedpercutaneouscryoablation AT fukushimayasuhiro radiationexposureofinterventionalradiologistsduringcomputedtomographyfluoroscopyguidedpercutaneouscryoablation AT andomasashi radiationexposureofinterventionalradiologistsduringcomputedtomographyfluoroscopyguidedpercutaneouscryoablation AT tsushimayoshito radiationexposureofinterventionalradiologistsduringcomputedtomographyfluoroscopyguidedpercutaneouscryoablation |