Comparative Study of Conventional Inverted ILM Flap Covering and ILM Flap Filling Technique in Idiopathic Macular Hole Treatment: A Meta-Analysis and Systematic Review

OBJECTIVE: This meta-analysis was performed to evaluate the anatomical efficacy and functional improvement of the conventional inverted internal limiting membrane (ILM), flap covering technique, and ILM flap filling technique for patients with idiopathic macular hole (MH). METHODS: Literature from P...

Descripción completa

Detalles Bibliográficos
Autores principales: Tao, Mengying, Wang, Guoqing, Gou, Yueqin, Zhang, Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553370/
https://www.ncbi.nlm.nih.gov/pubmed/36237559
http://dx.doi.org/10.1155/2022/4922616
_version_ 1784806454985752576
author Tao, Mengying
Wang, Guoqing
Gou, Yueqin
Zhang, Ming
author_facet Tao, Mengying
Wang, Guoqing
Gou, Yueqin
Zhang, Ming
author_sort Tao, Mengying
collection PubMed
description OBJECTIVE: This meta-analysis was performed to evaluate the anatomical efficacy and functional improvement of the conventional inverted internal limiting membrane (ILM), flap covering technique, and ILM flap filling technique for patients with idiopathic macular hole (MH). METHODS: Literature from Pubmed, Embase, Cochrane Central Register of Controlled Trials, and Web of Science were comprehensively retrieved. The primary outcomes included the MH closure rate and postoperative best-corrected visual acuity (BCVA). The secondary outcomes were the proportion of external limiting membrane (ELM) and ellipsoid zone (EZ) defect recovery. Pooled odds ratios (ORs), weighted mean differences (WMDs), and 95% confidence intervals (CIs) were calculated using STATA 17.0 software. RESULTS: 7 studies that contained 139 eyes in the inverted ILM flap covering group and 121 eyes in the ILM flap filling group were selected. Pooled data suggested that the surgical treatment resulted in an overall MH closure rate of up to 97.12% (135/139 eyes) in the inverted ILM flap covering group and 99.17% (120/121 eyes) in the filling group, with no significant difference between the 2 groups (OR = 1.98, 95% CI: 0.55 to 7.09, and P=0.29). Similarly, the 2 techniques demonstrated equal effectiveness on the anatomical closure in MH with the average diameter smaller than 650 μm (OR = 2.17, 95% CI: 0.48 to 9.77, and P=0.31) and larger than 650 μm (OR = 1.58, 95% CI: 0.14 to 17.37, and P=0.71). However, compared with the filling technique, the inverted ILM flap covering technique was superior in postoperative BCVA (WMD = 0.11, 95% CI: 0.04 to 0.18, and P=0.0017) and presented a significantly higher proportion of reconstitution of ELM (OR = 0.02, 95% CI: 0.00 to 0.08, and P < 0.0001) and EZ (OR = 0.11, 95% CI: 0.04 to 0.32, and P=0.0001). CONCLUSION: The inverted ILM flap covering technique was associated with the superior reconstitution of outer layers of the retina, including ELM and EZ, and more improvement in postoperative BCVA than the ILM flap filling technique.
format Online
Article
Text
id pubmed-9553370
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-95533702022-10-12 Comparative Study of Conventional Inverted ILM Flap Covering and ILM Flap Filling Technique in Idiopathic Macular Hole Treatment: A Meta-Analysis and Systematic Review Tao, Mengying Wang, Guoqing Gou, Yueqin Zhang, Ming J Ophthalmol Review Article OBJECTIVE: This meta-analysis was performed to evaluate the anatomical efficacy and functional improvement of the conventional inverted internal limiting membrane (ILM), flap covering technique, and ILM flap filling technique for patients with idiopathic macular hole (MH). METHODS: Literature from Pubmed, Embase, Cochrane Central Register of Controlled Trials, and Web of Science were comprehensively retrieved. The primary outcomes included the MH closure rate and postoperative best-corrected visual acuity (BCVA). The secondary outcomes were the proportion of external limiting membrane (ELM) and ellipsoid zone (EZ) defect recovery. Pooled odds ratios (ORs), weighted mean differences (WMDs), and 95% confidence intervals (CIs) were calculated using STATA 17.0 software. RESULTS: 7 studies that contained 139 eyes in the inverted ILM flap covering group and 121 eyes in the ILM flap filling group were selected. Pooled data suggested that the surgical treatment resulted in an overall MH closure rate of up to 97.12% (135/139 eyes) in the inverted ILM flap covering group and 99.17% (120/121 eyes) in the filling group, with no significant difference between the 2 groups (OR = 1.98, 95% CI: 0.55 to 7.09, and P=0.29). Similarly, the 2 techniques demonstrated equal effectiveness on the anatomical closure in MH with the average diameter smaller than 650 μm (OR = 2.17, 95% CI: 0.48 to 9.77, and P=0.31) and larger than 650 μm (OR = 1.58, 95% CI: 0.14 to 17.37, and P=0.71). However, compared with the filling technique, the inverted ILM flap covering technique was superior in postoperative BCVA (WMD = 0.11, 95% CI: 0.04 to 0.18, and P=0.0017) and presented a significantly higher proportion of reconstitution of ELM (OR = 0.02, 95% CI: 0.00 to 0.08, and P < 0.0001) and EZ (OR = 0.11, 95% CI: 0.04 to 0.32, and P=0.0001). CONCLUSION: The inverted ILM flap covering technique was associated with the superior reconstitution of outer layers of the retina, including ELM and EZ, and more improvement in postoperative BCVA than the ILM flap filling technique. Hindawi 2022-09-19 /pmc/articles/PMC9553370/ /pubmed/36237559 http://dx.doi.org/10.1155/2022/4922616 Text en Copyright © 2022 Mengying Tao et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Tao, Mengying
Wang, Guoqing
Gou, Yueqin
Zhang, Ming
Comparative Study of Conventional Inverted ILM Flap Covering and ILM Flap Filling Technique in Idiopathic Macular Hole Treatment: A Meta-Analysis and Systematic Review
title Comparative Study of Conventional Inverted ILM Flap Covering and ILM Flap Filling Technique in Idiopathic Macular Hole Treatment: A Meta-Analysis and Systematic Review
title_full Comparative Study of Conventional Inverted ILM Flap Covering and ILM Flap Filling Technique in Idiopathic Macular Hole Treatment: A Meta-Analysis and Systematic Review
title_fullStr Comparative Study of Conventional Inverted ILM Flap Covering and ILM Flap Filling Technique in Idiopathic Macular Hole Treatment: A Meta-Analysis and Systematic Review
title_full_unstemmed Comparative Study of Conventional Inverted ILM Flap Covering and ILM Flap Filling Technique in Idiopathic Macular Hole Treatment: A Meta-Analysis and Systematic Review
title_short Comparative Study of Conventional Inverted ILM Flap Covering and ILM Flap Filling Technique in Idiopathic Macular Hole Treatment: A Meta-Analysis and Systematic Review
title_sort comparative study of conventional inverted ilm flap covering and ilm flap filling technique in idiopathic macular hole treatment: a meta-analysis and systematic review
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553370/
https://www.ncbi.nlm.nih.gov/pubmed/36237559
http://dx.doi.org/10.1155/2022/4922616
work_keys_str_mv AT taomengying comparativestudyofconventionalinvertedilmflapcoveringandilmflapfillingtechniqueinidiopathicmacularholetreatmentametaanalysisandsystematicreview
AT wangguoqing comparativestudyofconventionalinvertedilmflapcoveringandilmflapfillingtechniqueinidiopathicmacularholetreatmentametaanalysisandsystematicreview
AT gouyueqin comparativestudyofconventionalinvertedilmflapcoveringandilmflapfillingtechniqueinidiopathicmacularholetreatmentametaanalysisandsystematicreview
AT zhangming comparativestudyofconventionalinvertedilmflapcoveringandilmflapfillingtechniqueinidiopathicmacularholetreatmentametaanalysisandsystematicreview