Cargando…

Load Test Analysis of a Long-Span Prestressed Nano-Concrete Highway Bridge

In order to solve the problem of vehicle-bridge coupling vibration of a continuous semisteel bridge, the main bridge type of long-span prestressed concrete girder bridge, the author proposes a bridge safety test system based on the dynamic and static load test. The system combines the change of stre...

Descripción completa

Detalles Bibliográficos
Autor principal: Yan, Liang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553651/
https://www.ncbi.nlm.nih.gov/pubmed/36245781
http://dx.doi.org/10.1155/2022/5169548
_version_ 1784806523846787072
author Yan, Liang
author_facet Yan, Liang
author_sort Yan, Liang
collection PubMed
description In order to solve the problem of vehicle-bridge coupling vibration of a continuous semisteel bridge, the main bridge type of long-span prestressed concrete girder bridge, the author proposes a bridge safety test system based on the dynamic and static load test. The system combines the change of stress and deflection with the vibration amplitude of the bridge body, and using the modeling assistant in large-scale finite element software MIDAS/CIVIL, a three-dimensional finite element real bridge model is established, including input of section data, the input of boundary conditions, and the input of loads. The result obtained is as follows: the structural verification coefficient of the control strain of the main girder under each working condition is not greater than 1.0, indicating that the flexural rigidity of the structure meets the design requirements. In addition, under each working condition, the ratio of the residual strain after unloading to the measured total strain is less than 20%. Under each working condition, the deflection calibration coefficient of each control section is less than 1.0, and the ratio of residual deflection to total deflection of each measuring point is at most 3.9%; each residual deflection is small. The damping ratios are all less than 5% of the empirical damping ratio of concrete members, indicating that the bridge structure is in good condition. The result obtained by the author is compared with the standard allowable value and the theoretical calculation value, so as to provide a basis for the study of the bearing capacity of similar bridges and to verify the standardization and rationality of the existing bridge structural design.
format Online
Article
Text
id pubmed-9553651
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-95536512022-10-13 Load Test Analysis of a Long-Span Prestressed Nano-Concrete Highway Bridge Yan, Liang Int J Anal Chem Research Article In order to solve the problem of vehicle-bridge coupling vibration of a continuous semisteel bridge, the main bridge type of long-span prestressed concrete girder bridge, the author proposes a bridge safety test system based on the dynamic and static load test. The system combines the change of stress and deflection with the vibration amplitude of the bridge body, and using the modeling assistant in large-scale finite element software MIDAS/CIVIL, a three-dimensional finite element real bridge model is established, including input of section data, the input of boundary conditions, and the input of loads. The result obtained is as follows: the structural verification coefficient of the control strain of the main girder under each working condition is not greater than 1.0, indicating that the flexural rigidity of the structure meets the design requirements. In addition, under each working condition, the ratio of the residual strain after unloading to the measured total strain is less than 20%. Under each working condition, the deflection calibration coefficient of each control section is less than 1.0, and the ratio of residual deflection to total deflection of each measuring point is at most 3.9%; each residual deflection is small. The damping ratios are all less than 5% of the empirical damping ratio of concrete members, indicating that the bridge structure is in good condition. The result obtained by the author is compared with the standard allowable value and the theoretical calculation value, so as to provide a basis for the study of the bearing capacity of similar bridges and to verify the standardization and rationality of the existing bridge structural design. Hindawi 2022-09-30 /pmc/articles/PMC9553651/ /pubmed/36245781 http://dx.doi.org/10.1155/2022/5169548 Text en Copyright © 2022 Liang Yan. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Yan, Liang
Load Test Analysis of a Long-Span Prestressed Nano-Concrete Highway Bridge
title Load Test Analysis of a Long-Span Prestressed Nano-Concrete Highway Bridge
title_full Load Test Analysis of a Long-Span Prestressed Nano-Concrete Highway Bridge
title_fullStr Load Test Analysis of a Long-Span Prestressed Nano-Concrete Highway Bridge
title_full_unstemmed Load Test Analysis of a Long-Span Prestressed Nano-Concrete Highway Bridge
title_short Load Test Analysis of a Long-Span Prestressed Nano-Concrete Highway Bridge
title_sort load test analysis of a long-span prestressed nano-concrete highway bridge
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553651/
https://www.ncbi.nlm.nih.gov/pubmed/36245781
http://dx.doi.org/10.1155/2022/5169548
work_keys_str_mv AT yanliang loadtestanalysisofalongspanprestressednanoconcretehighwaybridge