Cargando…

In Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars

OBJECTIVES: The percentage of failure of endodontically treated maxillary molars is relatively high; one main reason is that the second mesiobuccal canal (MB2) is missing. Some techniques have been proposed for detection of the MB2. This study was aimed at assessing the diagnostic accuracy and agree...

Descripción completa

Detalles Bibliográficos
Autores principales: Khademi, Abbasali, Saatchi, Masoud, Sheikhi, Mahnaz, Soltani, Mohammad Mehdi, Moradi, Samane
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553662/
https://www.ncbi.nlm.nih.gov/pubmed/36263096
http://dx.doi.org/10.1155/2022/1493153
_version_ 1784806526561550336
author Khademi, Abbasali
Saatchi, Masoud
Sheikhi, Mahnaz
Soltani, Mohammad Mehdi
Moradi, Samane
author_facet Khademi, Abbasali
Saatchi, Masoud
Sheikhi, Mahnaz
Soltani, Mohammad Mehdi
Moradi, Samane
author_sort Khademi, Abbasali
collection PubMed
description OBJECTIVES: The percentage of failure of endodontically treated maxillary molars is relatively high; one main reason is that the second mesiobuccal canal (MB2) is missing. Some techniques have been proposed for detection of the MB2. This study was aimed at assessing the diagnostic accuracy and agreement of the dental microscope and cone-beam computed tomography (CBCT) in comparison with microcomputed tomography (micro-CT) for detection of the MB2 of maxillary first molars in vitro. MATERIALS AND METHODS: This in vitro, experimental study evaluated 71 permanent maxillary first molars that were stored in 100% humidity at room temperature. The teeth were mounted in 9 silicone dental arches to the level of their cementoenamel junction (8 teeth in each arch). The blocks underwent CBCT in a XG3D scanner. Access cavity was then prepared, and the teeth were inspected by a surgical microscope for negotiation of the MB2. Also, micro-CT images were obtained from the teeth to serve as the gold standard. CBCT and micro-CT images were observed by two examiners twice with a 2-week interval. RESULTS: The frequency of the MB2 detected by dental microscope was significantly lower than micro-CT (P < 0.001) and CBCT (P = 0.008); no significant difference existed between micro-CT and CBCT in this respect. The sensitivity, specificity, positive predictive value, and negative predictive value of CBCT for detection of MB2 were 92.6%, 100%, 100%, and 81%, respectively. CONCLUSION: CBCT is superior to the dental microscope for detection of the MB2 of maxillary first molars and can be used for this purpose in the clinical setting with adequate accuracy.
format Online
Article
Text
id pubmed-9553662
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-95536622022-10-18 In Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars Khademi, Abbasali Saatchi, Masoud Sheikhi, Mahnaz Soltani, Mohammad Mehdi Moradi, Samane Scanning Research Article OBJECTIVES: The percentage of failure of endodontically treated maxillary molars is relatively high; one main reason is that the second mesiobuccal canal (MB2) is missing. Some techniques have been proposed for detection of the MB2. This study was aimed at assessing the diagnostic accuracy and agreement of the dental microscope and cone-beam computed tomography (CBCT) in comparison with microcomputed tomography (micro-CT) for detection of the MB2 of maxillary first molars in vitro. MATERIALS AND METHODS: This in vitro, experimental study evaluated 71 permanent maxillary first molars that were stored in 100% humidity at room temperature. The teeth were mounted in 9 silicone dental arches to the level of their cementoenamel junction (8 teeth in each arch). The blocks underwent CBCT in a XG3D scanner. Access cavity was then prepared, and the teeth were inspected by a surgical microscope for negotiation of the MB2. Also, micro-CT images were obtained from the teeth to serve as the gold standard. CBCT and micro-CT images were observed by two examiners twice with a 2-week interval. RESULTS: The frequency of the MB2 detected by dental microscope was significantly lower than micro-CT (P < 0.001) and CBCT (P = 0.008); no significant difference existed between micro-CT and CBCT in this respect. The sensitivity, specificity, positive predictive value, and negative predictive value of CBCT for detection of MB2 were 92.6%, 100%, 100%, and 81%, respectively. CONCLUSION: CBCT is superior to the dental microscope for detection of the MB2 of maxillary first molars and can be used for this purpose in the clinical setting with adequate accuracy. Hindawi 2022-09-19 /pmc/articles/PMC9553662/ /pubmed/36263096 http://dx.doi.org/10.1155/2022/1493153 Text en Copyright © 2022 Abbasali Khademi et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Khademi, Abbasali
Saatchi, Masoud
Sheikhi, Mahnaz
Soltani, Mohammad Mehdi
Moradi, Samane
In Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars
title In Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars
title_full In Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars
title_fullStr In Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars
title_full_unstemmed In Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars
title_short In Vitro Diagnostic Accuracy and Agreement of Dental Microscope and Cone-Beam Computed Tomography in Comparison with Microcomputed Tomography for Detection of the Second Mesiobuccal Canal of Maxillary First Molars
title_sort in vitro diagnostic accuracy and agreement of dental microscope and cone-beam computed tomography in comparison with microcomputed tomography for detection of the second mesiobuccal canal of maxillary first molars
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553662/
https://www.ncbi.nlm.nih.gov/pubmed/36263096
http://dx.doi.org/10.1155/2022/1493153
work_keys_str_mv AT khademiabbasali invitrodiagnosticaccuracyandagreementofdentalmicroscopeandconebeamcomputedtomographyincomparisonwithmicrocomputedtomographyfordetectionofthesecondmesiobuccalcanalofmaxillaryfirstmolars
AT saatchimasoud invitrodiagnosticaccuracyandagreementofdentalmicroscopeandconebeamcomputedtomographyincomparisonwithmicrocomputedtomographyfordetectionofthesecondmesiobuccalcanalofmaxillaryfirstmolars
AT sheikhimahnaz invitrodiagnosticaccuracyandagreementofdentalmicroscopeandconebeamcomputedtomographyincomparisonwithmicrocomputedtomographyfordetectionofthesecondmesiobuccalcanalofmaxillaryfirstmolars
AT soltanimohammadmehdi invitrodiagnosticaccuracyandagreementofdentalmicroscopeandconebeamcomputedtomographyincomparisonwithmicrocomputedtomographyfordetectionofthesecondmesiobuccalcanalofmaxillaryfirstmolars
AT moradisamane invitrodiagnosticaccuracyandagreementofdentalmicroscopeandconebeamcomputedtomographyincomparisonwithmicrocomputedtomographyfordetectionofthesecondmesiobuccalcanalofmaxillaryfirstmolars