Cargando…

Real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study

INTRODUCTION: Rotational thromboelastometry (ROTEM) records whole blood coagulation in vitro. Data on dynamic changes of clot patterns during intravenous thrombolysis (IVT) in acute ischemic stroke is scarce. We investigated the feasibility of ROTEM as a potential point-of-care assessment tool for I...

Descripción completa

Detalles Bibliográficos
Autores principales: Tinchon, Alexander, Freydl, Elisabeth, Fitzgerald, Robert D., Duarte, Christina, Weber, Michael, Calabek-Wohinz, Bernadette, Waiß, Christoph, Oberndorfer, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553850/
https://www.ncbi.nlm.nih.gov/pubmed/35852602
http://dx.doi.org/10.1007/s00415-022-11271-z
_version_ 1784806570222157824
author Tinchon, Alexander
Freydl, Elisabeth
Fitzgerald, Robert D.
Duarte, Christina
Weber, Michael
Calabek-Wohinz, Bernadette
Waiß, Christoph
Oberndorfer, Stefan
author_facet Tinchon, Alexander
Freydl, Elisabeth
Fitzgerald, Robert D.
Duarte, Christina
Weber, Michael
Calabek-Wohinz, Bernadette
Waiß, Christoph
Oberndorfer, Stefan
author_sort Tinchon, Alexander
collection PubMed
description INTRODUCTION: Rotational thromboelastometry (ROTEM) records whole blood coagulation in vitro. Data on dynamic changes of clot patterns during intravenous thrombolysis (IVT) in acute ischemic stroke is scarce. We investigated the feasibility of ROTEM as a potential point-of-care assessment tool for IVT. METHODS: In this prospective pilot study, patients with acute stroke symptoms received IVT. Whole blood coagulation was tracked on the ROTEM analyzer. Blood samples were analyzed before, and then 2, 15, 30 and 60 min after beginning IVT. In vitro clots (iCLs) were described by their maximum clot firmness (MCF), the time needed to reach MCF (MCF-t), as well as the area under the curve (AR10). National Institutes of Health Stroke Scale (NIHSS) was used as early clinical outcome parameter. RESULTS: We analyzed 288 iCLs from 12 patients undergoing IVT. In all iCLs, an early fibrinolysis (91% within the first 10 min) was detected during IVT. Three different curve progression patterns were observed: a low-responder pattern with a continuous clot increase, a high-responder pattern with a sustained clot decrease or total clotting suppression and an intermediate-responder pattern with alternating clot characteristics. There was a difference among these groups in early clinical outcome (AR10 and MCF each p = 0.01, MCF-t p = 0.02, Kruskal–Wallis Test). CONCLUSION: The fibrinolysis patterns determined using ROTEM allow for the monitoring of IVT in patients with acute ischemic stroke. This pilot study found a correlation between the in vitro fibrinolysis patterns and early clinical outcomes. These findings support a potential for individualization of IVT in the future. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00415-022-11271-z.
format Online
Article
Text
id pubmed-9553850
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-95538502022-10-13 Real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study Tinchon, Alexander Freydl, Elisabeth Fitzgerald, Robert D. Duarte, Christina Weber, Michael Calabek-Wohinz, Bernadette Waiß, Christoph Oberndorfer, Stefan J Neurol Short Commentary INTRODUCTION: Rotational thromboelastometry (ROTEM) records whole blood coagulation in vitro. Data on dynamic changes of clot patterns during intravenous thrombolysis (IVT) in acute ischemic stroke is scarce. We investigated the feasibility of ROTEM as a potential point-of-care assessment tool for IVT. METHODS: In this prospective pilot study, patients with acute stroke symptoms received IVT. Whole blood coagulation was tracked on the ROTEM analyzer. Blood samples were analyzed before, and then 2, 15, 30 and 60 min after beginning IVT. In vitro clots (iCLs) were described by their maximum clot firmness (MCF), the time needed to reach MCF (MCF-t), as well as the area under the curve (AR10). National Institutes of Health Stroke Scale (NIHSS) was used as early clinical outcome parameter. RESULTS: We analyzed 288 iCLs from 12 patients undergoing IVT. In all iCLs, an early fibrinolysis (91% within the first 10 min) was detected during IVT. Three different curve progression patterns were observed: a low-responder pattern with a continuous clot increase, a high-responder pattern with a sustained clot decrease or total clotting suppression and an intermediate-responder pattern with alternating clot characteristics. There was a difference among these groups in early clinical outcome (AR10 and MCF each p = 0.01, MCF-t p = 0.02, Kruskal–Wallis Test). CONCLUSION: The fibrinolysis patterns determined using ROTEM allow for the monitoring of IVT in patients with acute ischemic stroke. This pilot study found a correlation between the in vitro fibrinolysis patterns and early clinical outcomes. These findings support a potential for individualization of IVT in the future. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00415-022-11271-z. Springer Berlin Heidelberg 2022-07-19 2022 /pmc/articles/PMC9553850/ /pubmed/35852602 http://dx.doi.org/10.1007/s00415-022-11271-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Short Commentary
Tinchon, Alexander
Freydl, Elisabeth
Fitzgerald, Robert D.
Duarte, Christina
Weber, Michael
Calabek-Wohinz, Bernadette
Waiß, Christoph
Oberndorfer, Stefan
Real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study
title Real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study
title_full Real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study
title_fullStr Real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study
title_full_unstemmed Real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study
title_short Real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study
title_sort real-time monitoring of intravenous thrombolysis in acute ischemic stroke using rotational thromboelastometry: a feasibility pilot study
topic Short Commentary
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9553850/
https://www.ncbi.nlm.nih.gov/pubmed/35852602
http://dx.doi.org/10.1007/s00415-022-11271-z
work_keys_str_mv AT tinchonalexander realtimemonitoringofintravenousthrombolysisinacuteischemicstrokeusingrotationalthromboelastometryafeasibilitypilotstudy
AT freydlelisabeth realtimemonitoringofintravenousthrombolysisinacuteischemicstrokeusingrotationalthromboelastometryafeasibilitypilotstudy
AT fitzgeraldrobertd realtimemonitoringofintravenousthrombolysisinacuteischemicstrokeusingrotationalthromboelastometryafeasibilitypilotstudy
AT duartechristina realtimemonitoringofintravenousthrombolysisinacuteischemicstrokeusingrotationalthromboelastometryafeasibilitypilotstudy
AT webermichael realtimemonitoringofintravenousthrombolysisinacuteischemicstrokeusingrotationalthromboelastometryafeasibilitypilotstudy
AT calabekwohinzbernadette realtimemonitoringofintravenousthrombolysisinacuteischemicstrokeusingrotationalthromboelastometryafeasibilitypilotstudy
AT waißchristoph realtimemonitoringofintravenousthrombolysisinacuteischemicstrokeusingrotationalthromboelastometryafeasibilitypilotstudy
AT oberndorferstefan realtimemonitoringofintravenousthrombolysisinacuteischemicstrokeusingrotationalthromboelastometryafeasibilitypilotstudy