Cargando…
Glaucoma Diagnostic Performance of Retinal Blood Flow Measurement With Doppler Optical Coherence Tomography
PURPOSE: The purpose of this study was to evaluate the diagnostic performance of retinal blood flow (RBF) measured with the Doppler optical coherence tomography (OCT) segmental scanning method to distinguish between healthy and glaucoma eyes. METHODS: Fifty-eight patients with normal tension glaucom...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9554227/ https://www.ncbi.nlm.nih.gov/pubmed/36201201 http://dx.doi.org/10.1167/tvst.11.10.11 |
_version_ | 1784806645184856064 |
---|---|
author | Abe, Tsubasa Yoshioka, Takafumi Song, Youngseok Tani, Tomofumi Kawai, Motofumi Omae, Tsuneaki Takahashi, Kengo Takizawa, Yoshitaka Ro-Mase, Tomoko Ishiko, Satoshi Minamide, Kana Sakai, Jun Akiba, Masahiro Hashimoto, Yohei Yoshida, Akitoshi |
author_facet | Abe, Tsubasa Yoshioka, Takafumi Song, Youngseok Tani, Tomofumi Kawai, Motofumi Omae, Tsuneaki Takahashi, Kengo Takizawa, Yoshitaka Ro-Mase, Tomoko Ishiko, Satoshi Minamide, Kana Sakai, Jun Akiba, Masahiro Hashimoto, Yohei Yoshida, Akitoshi |
author_sort | Abe, Tsubasa |
collection | PubMed |
description | PURPOSE: The purpose of this study was to evaluate the diagnostic performance of retinal blood flow (RBF) measured with the Doppler optical coherence tomography (OCT) segmental scanning method to distinguish between healthy and glaucoma eyes. METHODS: Fifty-eight patients with normal tension glaucoma (NTG) who had a single-hemifield visual field defect and 44 age-matched healthy subjects were enrolled. Retinal nerve fiber layer thickness (RNFLT) was measured with swept-source OCT. Superior and inferior temporal arteries (TAs) and temporal veins (TVs) RBF were measured with Doppler OCT. The area under the curve (AUC) of the receiver operating characteristic (ROC) was used to compare the diagnostic performances in the damaged and normal hemispheres. RESULTS: Multivariate regression analysis showed TA RBF and TV RBF were significantly reduced in the damaged and normal hemispheres. The ROC analysis showed that the AUC for quadrant RNFLT, TA RBF, and TV RBF were 0.973, 0.909, and 0.872 in the damaged hemisphere, respectively. The AUC values in the normal hemisphere were 0.783, 0.744, and 0.697, respectively. The combination of quadrant RNFLT and TA/TV RBF had a greater AUC than quadrant RNFLT alone in both damaged (AUC = 0.987) and normal (AUC = 0.825) hemispheres. CONCLUSIONS: In NTG eyes with single-hemifield damage, the RBF was found to be significantly reduced in the damaged and normal hemispheres independent from structural changes. The combination of RNFLT and RBF could improve diagnostic performances for glaucoma. TRANSLATIONAL RELEVANCE: Combining morphological and blood flow measurements with Doppler OCT may be useful in glaucoma diagnosis. |
format | Online Article Text |
id | pubmed-9554227 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-95542272022-10-13 Glaucoma Diagnostic Performance of Retinal Blood Flow Measurement With Doppler Optical Coherence Tomography Abe, Tsubasa Yoshioka, Takafumi Song, Youngseok Tani, Tomofumi Kawai, Motofumi Omae, Tsuneaki Takahashi, Kengo Takizawa, Yoshitaka Ro-Mase, Tomoko Ishiko, Satoshi Minamide, Kana Sakai, Jun Akiba, Masahiro Hashimoto, Yohei Yoshida, Akitoshi Transl Vis Sci Technol Glaucoma PURPOSE: The purpose of this study was to evaluate the diagnostic performance of retinal blood flow (RBF) measured with the Doppler optical coherence tomography (OCT) segmental scanning method to distinguish between healthy and glaucoma eyes. METHODS: Fifty-eight patients with normal tension glaucoma (NTG) who had a single-hemifield visual field defect and 44 age-matched healthy subjects were enrolled. Retinal nerve fiber layer thickness (RNFLT) was measured with swept-source OCT. Superior and inferior temporal arteries (TAs) and temporal veins (TVs) RBF were measured with Doppler OCT. The area under the curve (AUC) of the receiver operating characteristic (ROC) was used to compare the diagnostic performances in the damaged and normal hemispheres. RESULTS: Multivariate regression analysis showed TA RBF and TV RBF were significantly reduced in the damaged and normal hemispheres. The ROC analysis showed that the AUC for quadrant RNFLT, TA RBF, and TV RBF were 0.973, 0.909, and 0.872 in the damaged hemisphere, respectively. The AUC values in the normal hemisphere were 0.783, 0.744, and 0.697, respectively. The combination of quadrant RNFLT and TA/TV RBF had a greater AUC than quadrant RNFLT alone in both damaged (AUC = 0.987) and normal (AUC = 0.825) hemispheres. CONCLUSIONS: In NTG eyes with single-hemifield damage, the RBF was found to be significantly reduced in the damaged and normal hemispheres independent from structural changes. The combination of RNFLT and RBF could improve diagnostic performances for glaucoma. TRANSLATIONAL RELEVANCE: Combining morphological and blood flow measurements with Doppler OCT may be useful in glaucoma diagnosis. The Association for Research in Vision and Ophthalmology 2022-10-06 /pmc/articles/PMC9554227/ /pubmed/36201201 http://dx.doi.org/10.1167/tvst.11.10.11 Text en Copyright 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Glaucoma Abe, Tsubasa Yoshioka, Takafumi Song, Youngseok Tani, Tomofumi Kawai, Motofumi Omae, Tsuneaki Takahashi, Kengo Takizawa, Yoshitaka Ro-Mase, Tomoko Ishiko, Satoshi Minamide, Kana Sakai, Jun Akiba, Masahiro Hashimoto, Yohei Yoshida, Akitoshi Glaucoma Diagnostic Performance of Retinal Blood Flow Measurement With Doppler Optical Coherence Tomography |
title | Glaucoma Diagnostic Performance of Retinal Blood Flow Measurement With Doppler Optical Coherence Tomography |
title_full | Glaucoma Diagnostic Performance of Retinal Blood Flow Measurement With Doppler Optical Coherence Tomography |
title_fullStr | Glaucoma Diagnostic Performance of Retinal Blood Flow Measurement With Doppler Optical Coherence Tomography |
title_full_unstemmed | Glaucoma Diagnostic Performance of Retinal Blood Flow Measurement With Doppler Optical Coherence Tomography |
title_short | Glaucoma Diagnostic Performance of Retinal Blood Flow Measurement With Doppler Optical Coherence Tomography |
title_sort | glaucoma diagnostic performance of retinal blood flow measurement with doppler optical coherence tomography |
topic | Glaucoma |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9554227/ https://www.ncbi.nlm.nih.gov/pubmed/36201201 http://dx.doi.org/10.1167/tvst.11.10.11 |
work_keys_str_mv | AT abetsubasa glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT yoshiokatakafumi glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT songyoungseok glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT tanitomofumi glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT kawaimotofumi glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT omaetsuneaki glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT takahashikengo glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT takizawayoshitaka glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT romasetomoko glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT ishikosatoshi glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT minamidekana glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT sakaijun glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT akibamasahiro glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT hashimotoyohei glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography AT yoshidaakitoshi glaucomadiagnosticperformanceofretinalbloodflowmeasurementwithdoppleropticalcoherencetomography |