Cargando…

Measurement of the Macular Hole Diameter by En Face Slab Optical Coherence Tomography Reflectance Imaging

PURPOSE: To evaluate the repeatability of macular hole (MH) diameter measurement on en face slab optical coherence tomography (OCT) reflectance images and assess its potential to predict visual acuity (VA). METHODS: We enrolled 27 eyes with full-thickness MHs in this study. Preoperative en face slab...

Descripción completa

Detalles Bibliográficos
Autores principales: Uechi, Yuna, Nakamura, Kentaro, Shinozuka, Masato, Kawasaki, Shohei, Okawa, Kazuyoshi, Inoue, Tatsuya, Asaoka, Ryo, Maruyama-Inoue, Maiko, Yanagi, Yasuo, Kadonosono, Kazuaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9554266/
https://www.ncbi.nlm.nih.gov/pubmed/36201199
http://dx.doi.org/10.1167/tvst.11.10.13
_version_ 1784806654418616320
author Uechi, Yuna
Nakamura, Kentaro
Shinozuka, Masato
Kawasaki, Shohei
Okawa, Kazuyoshi
Inoue, Tatsuya
Asaoka, Ryo
Maruyama-Inoue, Maiko
Yanagi, Yasuo
Kadonosono, Kazuaki
author_facet Uechi, Yuna
Nakamura, Kentaro
Shinozuka, Masato
Kawasaki, Shohei
Okawa, Kazuyoshi
Inoue, Tatsuya
Asaoka, Ryo
Maruyama-Inoue, Maiko
Yanagi, Yasuo
Kadonosono, Kazuaki
author_sort Uechi, Yuna
collection PubMed
description PURPOSE: To evaluate the repeatability of macular hole (MH) diameter measurement on en face slab optical coherence tomography (OCT) reflectance images and assess its potential to predict visual acuity (VA). METHODS: We enrolled 27 eyes with full-thickness MHs in this study. Preoperative en face slab OCT reflectance images were obtained. Image binarization, ellipse approximation, and uncorrected measurement of minimum diameter, min(ef_uc), and maximum diameter, max(ef_uc), were performed using ImageJ. In addition, magnification-corrected diameters were calculated as min(ef) and max(ef) using the Littman and modified Bennett formulas. Spectral-domain OCT horizontal images were used as the conventional method for the analysis: min(conv) and max(conv). The inter-rater reliability of the method was evaluated by calculating the intraclass correlation coefficient (ICC). The following relationships were analyzed: (1) between logMAR VA and min(ef_uc), min(ef), and min(conv); and (2) between logMAR VA and max(ef_uc), max(ef), and max(conv). RESULTS: The min(ef) and max(ef) values were 439.4 ± 240.5 µm and 720.7 ± 346.1 µm, respectively. The ICC values were 0.985 and 0.999 for min(ef) and max(ef), and 0.885 and 0.909 for min(conv) and max(conv), respectively. Multivariate analysis suggested that min(ef), but not min(ef_uc) or min(conv), was associated with pre- and postoperative logMAR VA. Furthermore, max(ef), but not max(ef_uc) or max(conv), was also closely correlated with pre- and postoperative logMAR VA. CONCLUSIONS: The MH diameter measured by our method is highly reproducible and closely associated with VA compared to that measured by the conventional method. TRANSLATIONAL RELEVANCE: The MH diameter measured by this modality might serve as an accurate biomarker to predict visual function in eyes with MH.
format Online
Article
Text
id pubmed-9554266
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-95542662022-10-13 Measurement of the Macular Hole Diameter by En Face Slab Optical Coherence Tomography Reflectance Imaging Uechi, Yuna Nakamura, Kentaro Shinozuka, Masato Kawasaki, Shohei Okawa, Kazuyoshi Inoue, Tatsuya Asaoka, Ryo Maruyama-Inoue, Maiko Yanagi, Yasuo Kadonosono, Kazuaki Transl Vis Sci Technol Retina PURPOSE: To evaluate the repeatability of macular hole (MH) diameter measurement on en face slab optical coherence tomography (OCT) reflectance images and assess its potential to predict visual acuity (VA). METHODS: We enrolled 27 eyes with full-thickness MHs in this study. Preoperative en face slab OCT reflectance images were obtained. Image binarization, ellipse approximation, and uncorrected measurement of minimum diameter, min(ef_uc), and maximum diameter, max(ef_uc), were performed using ImageJ. In addition, magnification-corrected diameters were calculated as min(ef) and max(ef) using the Littman and modified Bennett formulas. Spectral-domain OCT horizontal images were used as the conventional method for the analysis: min(conv) and max(conv). The inter-rater reliability of the method was evaluated by calculating the intraclass correlation coefficient (ICC). The following relationships were analyzed: (1) between logMAR VA and min(ef_uc), min(ef), and min(conv); and (2) between logMAR VA and max(ef_uc), max(ef), and max(conv). RESULTS: The min(ef) and max(ef) values were 439.4 ± 240.5 µm and 720.7 ± 346.1 µm, respectively. The ICC values were 0.985 and 0.999 for min(ef) and max(ef), and 0.885 and 0.909 for min(conv) and max(conv), respectively. Multivariate analysis suggested that min(ef), but not min(ef_uc) or min(conv), was associated with pre- and postoperative logMAR VA. Furthermore, max(ef), but not max(ef_uc) or max(conv), was also closely correlated with pre- and postoperative logMAR VA. CONCLUSIONS: The MH diameter measured by our method is highly reproducible and closely associated with VA compared to that measured by the conventional method. TRANSLATIONAL RELEVANCE: The MH diameter measured by this modality might serve as an accurate biomarker to predict visual function in eyes with MH. The Association for Research in Vision and Ophthalmology 2022-10-06 /pmc/articles/PMC9554266/ /pubmed/36201199 http://dx.doi.org/10.1167/tvst.11.10.13 Text en Copyright 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Retina
Uechi, Yuna
Nakamura, Kentaro
Shinozuka, Masato
Kawasaki, Shohei
Okawa, Kazuyoshi
Inoue, Tatsuya
Asaoka, Ryo
Maruyama-Inoue, Maiko
Yanagi, Yasuo
Kadonosono, Kazuaki
Measurement of the Macular Hole Diameter by En Face Slab Optical Coherence Tomography Reflectance Imaging
title Measurement of the Macular Hole Diameter by En Face Slab Optical Coherence Tomography Reflectance Imaging
title_full Measurement of the Macular Hole Diameter by En Face Slab Optical Coherence Tomography Reflectance Imaging
title_fullStr Measurement of the Macular Hole Diameter by En Face Slab Optical Coherence Tomography Reflectance Imaging
title_full_unstemmed Measurement of the Macular Hole Diameter by En Face Slab Optical Coherence Tomography Reflectance Imaging
title_short Measurement of the Macular Hole Diameter by En Face Slab Optical Coherence Tomography Reflectance Imaging
title_sort measurement of the macular hole diameter by en face slab optical coherence tomography reflectance imaging
topic Retina
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9554266/
https://www.ncbi.nlm.nih.gov/pubmed/36201199
http://dx.doi.org/10.1167/tvst.11.10.13
work_keys_str_mv AT uechiyuna measurementofthemacularholediameterbyenfaceslabopticalcoherencetomographyreflectanceimaging
AT nakamurakentaro measurementofthemacularholediameterbyenfaceslabopticalcoherencetomographyreflectanceimaging
AT shinozukamasato measurementofthemacularholediameterbyenfaceslabopticalcoherencetomographyreflectanceimaging
AT kawasakishohei measurementofthemacularholediameterbyenfaceslabopticalcoherencetomographyreflectanceimaging
AT okawakazuyoshi measurementofthemacularholediameterbyenfaceslabopticalcoherencetomographyreflectanceimaging
AT inouetatsuya measurementofthemacularholediameterbyenfaceslabopticalcoherencetomographyreflectanceimaging
AT asaokaryo measurementofthemacularholediameterbyenfaceslabopticalcoherencetomographyreflectanceimaging
AT maruyamainouemaiko measurementofthemacularholediameterbyenfaceslabopticalcoherencetomographyreflectanceimaging
AT yanagiyasuo measurementofthemacularholediameterbyenfaceslabopticalcoherencetomographyreflectanceimaging
AT kadonosonokazuaki measurementofthemacularholediameterbyenfaceslabopticalcoherencetomographyreflectanceimaging