Cargando…

A novel method for measuring pulmonary artery pressure by high-frequency ultrasound-guided transthoracic puncture in rats

OBJECTIVES: The success of the rat model of pulmonary hypertension (PH) is primarily dependent on the measurement of pulmonary artery pressure. We herein demonstrate a novel method for measuring pulmonary artery pressure through a high-frequency ultrasound-guided transthoracic puncture in rats. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Xiaofeng, Li, Jingtao, Zeng, Decai, Liang, Chunting, Zhong, Yanfen, Huang, Tongtong, Mo, Yingying, Rao, Huaqing, Pan, Xiaoxiong, Wu, Ji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9554409/
https://www.ncbi.nlm.nih.gov/pubmed/36247441
http://dx.doi.org/10.3389/fcvm.2022.995728
Descripción
Sumario:OBJECTIVES: The success of the rat model of pulmonary hypertension (PH) is primarily dependent on the measurement of pulmonary artery pressure. We herein demonstrate a novel method for measuring pulmonary artery pressure through a high-frequency ultrasound-guided transthoracic puncture in rats. The efficacy and time of this novel method are also discussed. METHODS: A single subcutaneous injection of monocrotaline (MCT) was used to establish a rat model of PH. Through the heat shaping method, the tip of that puncture cannula was maintained at a certain angle after the needle core was removed. In-plane real-time guided trocar puncture of the right ventricular outflow tract was performed in the short-axis section of the parasternal aorta. The external pressure sensor was used to record the real-time waveform of right ventricular systolic pressure, pulmonary artery systolic pressure, and diastolic pressure. RESULTS: The success rates of which using this novel method in the model group and the control group were 88.5 and 86.7%, respectively. The time of puncture pressure measurement was 164 ± 31 and 235 ± 50 s, respectively. The right ventricular systolic blood pressure, pulmonary systolic blood pressure, and diastolic blood pressure of the model group were higher than those of the control group. CONCLUSION: The modified method for trocar is helpful for accurately positioning pulmonary artery manometry. The method described in this paper has a high success rate and short operation time. It can simultaneously measure systolic blood pressure, diastolic blood pressure, and mean pressure of the right ventricle and pulmonary artery. It has a broad application prospect in verifying the rat PH model and pulmonary artery pressure monitoring.