Cargando…
Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction
Optoacoustic mesoscopy combines rich optical absorption contrast with high spatial resolution at tissue depths beyond reach for microscopic techniques employing focused light excitation. The mesoscopic imaging performance is commonly hindered by the use of inaccurate delay-and-sum reconstruction app...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9554813/ https://www.ncbi.nlm.nih.gov/pubmed/36246932 http://dx.doi.org/10.1016/j.pacs.2022.100405 |
_version_ | 1784806781886660608 |
---|---|
author | Hofmann, Urs A.T. Li, Weiye Deán-Ben, Xosé Luís Subochev, Pavel Estrada, Héctor Razansky, Daniel |
author_facet | Hofmann, Urs A.T. Li, Weiye Deán-Ben, Xosé Luís Subochev, Pavel Estrada, Héctor Razansky, Daniel |
author_sort | Hofmann, Urs A.T. |
collection | PubMed |
description | Optoacoustic mesoscopy combines rich optical absorption contrast with high spatial resolution at tissue depths beyond reach for microscopic techniques employing focused light excitation. The mesoscopic imaging performance is commonly hindered by the use of inaccurate delay-and-sum reconstruction approaches and idealized modeling assumptions. In principle, image reconstruction performance could be enhanced by simulating the optoacoustic signal generation, propagation, and detection path. However, for most realistic experimental scenarios, the underlying total impulse response (TIR) cannot be accurately modelled. Here we propose to capture the TIR by scanning of a sub-resolution sized absorber. Significant improvement of spatial resolution and depth uniformity is demonstrated over 3 mm range, outperforming delay-and-sum and model-based reconstruction implementations. Reconstruction performance is validated by imaging subcutaneous murine vasculature and human skin in vivo. The proposed experimental calibration and reconstruction paradigm facilitates quantitative inversions while averting complex physics-based simulations. It can readily be applied to other imaging modalities employing TIR-based reconstructions. |
format | Online Article Text |
id | pubmed-9554813 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-95548132022-10-13 Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction Hofmann, Urs A.T. Li, Weiye Deán-Ben, Xosé Luís Subochev, Pavel Estrada, Héctor Razansky, Daniel Photoacoustics Research Article Optoacoustic mesoscopy combines rich optical absorption contrast with high spatial resolution at tissue depths beyond reach for microscopic techniques employing focused light excitation. The mesoscopic imaging performance is commonly hindered by the use of inaccurate delay-and-sum reconstruction approaches and idealized modeling assumptions. In principle, image reconstruction performance could be enhanced by simulating the optoacoustic signal generation, propagation, and detection path. However, for most realistic experimental scenarios, the underlying total impulse response (TIR) cannot be accurately modelled. Here we propose to capture the TIR by scanning of a sub-resolution sized absorber. Significant improvement of spatial resolution and depth uniformity is demonstrated over 3 mm range, outperforming delay-and-sum and model-based reconstruction implementations. Reconstruction performance is validated by imaging subcutaneous murine vasculature and human skin in vivo. The proposed experimental calibration and reconstruction paradigm facilitates quantitative inversions while averting complex physics-based simulations. It can readily be applied to other imaging modalities employing TIR-based reconstructions. Elsevier 2022-09-23 /pmc/articles/PMC9554813/ /pubmed/36246932 http://dx.doi.org/10.1016/j.pacs.2022.100405 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Research Article Hofmann, Urs A.T. Li, Weiye Deán-Ben, Xosé Luís Subochev, Pavel Estrada, Héctor Razansky, Daniel Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction |
title | Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction |
title_full | Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction |
title_fullStr | Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction |
title_full_unstemmed | Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction |
title_short | Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction |
title_sort | enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9554813/ https://www.ncbi.nlm.nih.gov/pubmed/36246932 http://dx.doi.org/10.1016/j.pacs.2022.100405 |
work_keys_str_mv | AT hofmannursat enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction AT liweiye enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction AT deanbenxoseluis enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction AT subochevpavel enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction AT estradahector enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction AT razanskydaniel enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction |