Cargando…

Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction

Optoacoustic mesoscopy combines rich optical absorption contrast with high spatial resolution at tissue depths beyond reach for microscopic techniques employing focused light excitation. The mesoscopic imaging performance is commonly hindered by the use of inaccurate delay-and-sum reconstruction app...

Descripción completa

Detalles Bibliográficos
Autores principales: Hofmann, Urs A.T., Li, Weiye, Deán-Ben, Xosé Luís, Subochev, Pavel, Estrada, Héctor, Razansky, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9554813/
https://www.ncbi.nlm.nih.gov/pubmed/36246932
http://dx.doi.org/10.1016/j.pacs.2022.100405
_version_ 1784806781886660608
author Hofmann, Urs A.T.
Li, Weiye
Deán-Ben, Xosé Luís
Subochev, Pavel
Estrada, Héctor
Razansky, Daniel
author_facet Hofmann, Urs A.T.
Li, Weiye
Deán-Ben, Xosé Luís
Subochev, Pavel
Estrada, Héctor
Razansky, Daniel
author_sort Hofmann, Urs A.T.
collection PubMed
description Optoacoustic mesoscopy combines rich optical absorption contrast with high spatial resolution at tissue depths beyond reach for microscopic techniques employing focused light excitation. The mesoscopic imaging performance is commonly hindered by the use of inaccurate delay-and-sum reconstruction approaches and idealized modeling assumptions. In principle, image reconstruction performance could be enhanced by simulating the optoacoustic signal generation, propagation, and detection path. However, for most realistic experimental scenarios, the underlying total impulse response (TIR) cannot be accurately modelled. Here we propose to capture the TIR by scanning of a sub-resolution sized absorber. Significant improvement of spatial resolution and depth uniformity is demonstrated over 3 mm range, outperforming delay-and-sum and model-based reconstruction implementations. Reconstruction performance is validated by imaging subcutaneous murine vasculature and human skin in vivo. The proposed experimental calibration and reconstruction paradigm facilitates quantitative inversions while averting complex physics-based simulations. It can readily be applied to other imaging modalities employing TIR-based reconstructions.
format Online
Article
Text
id pubmed-9554813
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-95548132022-10-13 Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction Hofmann, Urs A.T. Li, Weiye Deán-Ben, Xosé Luís Subochev, Pavel Estrada, Héctor Razansky, Daniel Photoacoustics Research Article Optoacoustic mesoscopy combines rich optical absorption contrast with high spatial resolution at tissue depths beyond reach for microscopic techniques employing focused light excitation. The mesoscopic imaging performance is commonly hindered by the use of inaccurate delay-and-sum reconstruction approaches and idealized modeling assumptions. In principle, image reconstruction performance could be enhanced by simulating the optoacoustic signal generation, propagation, and detection path. However, for most realistic experimental scenarios, the underlying total impulse response (TIR) cannot be accurately modelled. Here we propose to capture the TIR by scanning of a sub-resolution sized absorber. Significant improvement of spatial resolution and depth uniformity is demonstrated over 3 mm range, outperforming delay-and-sum and model-based reconstruction implementations. Reconstruction performance is validated by imaging subcutaneous murine vasculature and human skin in vivo. The proposed experimental calibration and reconstruction paradigm facilitates quantitative inversions while averting complex physics-based simulations. It can readily be applied to other imaging modalities employing TIR-based reconstructions. Elsevier 2022-09-23 /pmc/articles/PMC9554813/ /pubmed/36246932 http://dx.doi.org/10.1016/j.pacs.2022.100405 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Research Article
Hofmann, Urs A.T.
Li, Weiye
Deán-Ben, Xosé Luís
Subochev, Pavel
Estrada, Héctor
Razansky, Daniel
Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction
title Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction
title_full Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction
title_fullStr Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction
title_full_unstemmed Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction
title_short Enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction
title_sort enhancing optoacoustic mesoscopy through calibration-based iterative reconstruction
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9554813/
https://www.ncbi.nlm.nih.gov/pubmed/36246932
http://dx.doi.org/10.1016/j.pacs.2022.100405
work_keys_str_mv AT hofmannursat enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction
AT liweiye enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction
AT deanbenxoseluis enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction
AT subochevpavel enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction
AT estradahector enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction
AT razanskydaniel enhancingoptoacousticmesoscopythroughcalibrationbasediterativereconstruction