Cargando…
Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures
BACKGROUND: Distal clavicular fracture is a shoulder joint injury that is common in clinical settings and is generally surgically treated using the clavicular hook plate technique with a confirmed curative effect. However, symptoms, such as shoulder abduction limitation, shoulder discomfort, and pos...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9555107/ https://www.ncbi.nlm.nih.gov/pubmed/36224636 http://dx.doi.org/10.1186/s13018-022-03338-4 |
_version_ | 1784806842541539328 |
---|---|
author | Li, Dashuang Qiao, Rui Yang, Na Zhang, Kun Zhu, Yangjun Song, Zhe |
author_facet | Li, Dashuang Qiao, Rui Yang, Na Zhang, Kun Zhu, Yangjun Song, Zhe |
author_sort | Li, Dashuang |
collection | PubMed |
description | BACKGROUND: Distal clavicular fracture is a shoulder joint injury that is common in clinical settings and is generally surgically treated using the clavicular hook plate technique with a confirmed curative effect. However, symptoms, such as shoulder abduction limitation, shoulder discomfort, and postoperative joint pain, may occur in some patients. To overcome these problems, after a previous study we developed an acromial height-measuring device and a new type of clavicular hook plate. This study aimed to investigate whether an acromial height-measuring device combined with an improved new-type clavicular hook plate can better reduce the incidence of complications and improve postoperative function. To provide patients with better treatment effects, an acromion gauge and clavicular hook plate are used. METHODS: A retrospective analysis was performed on 81 patients with distal clavicular fractures admitted to our hospital. They were divided into experimental and control groups according to different plates, and the Constant–Murley score, visual analogue scale score, incidence of acromion osteolysis, and incidence of subacromial impingement syndrome were compared. RESULTS: Compared with the standard clavicular hook plate, the acromial height-measuring device combined with the new-type clavicular hook plate in the treatment of distal clavicle fractures has a lower incidence of subacromial impingement syndrome with better postoperative functional recovery and quality of life. CONCLUSIONS: We considered the acromial height-measuring device combined with the new clavicular hook plate to be a safe and promising alternative to distal clavicular fractures. |
format | Online Article Text |
id | pubmed-9555107 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-95551072022-10-13 Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures Li, Dashuang Qiao, Rui Yang, Na Zhang, Kun Zhu, Yangjun Song, Zhe J Orthop Surg Res Review BACKGROUND: Distal clavicular fracture is a shoulder joint injury that is common in clinical settings and is generally surgically treated using the clavicular hook plate technique with a confirmed curative effect. However, symptoms, such as shoulder abduction limitation, shoulder discomfort, and postoperative joint pain, may occur in some patients. To overcome these problems, after a previous study we developed an acromial height-measuring device and a new type of clavicular hook plate. This study aimed to investigate whether an acromial height-measuring device combined with an improved new-type clavicular hook plate can better reduce the incidence of complications and improve postoperative function. To provide patients with better treatment effects, an acromion gauge and clavicular hook plate are used. METHODS: A retrospective analysis was performed on 81 patients with distal clavicular fractures admitted to our hospital. They were divided into experimental and control groups according to different plates, and the Constant–Murley score, visual analogue scale score, incidence of acromion osteolysis, and incidence of subacromial impingement syndrome were compared. RESULTS: Compared with the standard clavicular hook plate, the acromial height-measuring device combined with the new-type clavicular hook plate in the treatment of distal clavicle fractures has a lower incidence of subacromial impingement syndrome with better postoperative functional recovery and quality of life. CONCLUSIONS: We considered the acromial height-measuring device combined with the new clavicular hook plate to be a safe and promising alternative to distal clavicular fractures. BioMed Central 2022-10-12 /pmc/articles/PMC9555107/ /pubmed/36224636 http://dx.doi.org/10.1186/s13018-022-03338-4 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Review Li, Dashuang Qiao, Rui Yang, Na Zhang, Kun Zhu, Yangjun Song, Zhe Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures |
title | Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures |
title_full | Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures |
title_fullStr | Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures |
title_full_unstemmed | Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures |
title_short | Clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of Neer type II distal clavicle fractures |
title_sort | clinical analysis of the acromial height-measuring device combined with new-type clavicular hook plate and standard clavicular hook plate in the treatment of neer type ii distal clavicle fractures |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9555107/ https://www.ncbi.nlm.nih.gov/pubmed/36224636 http://dx.doi.org/10.1186/s13018-022-03338-4 |
work_keys_str_mv | AT lidashuang clinicalanalysisoftheacromialheightmeasuringdevicecombinedwithnewtypeclavicularhookplateandstandardclavicularhookplateinthetreatmentofneertypeiidistalclaviclefractures AT qiaorui clinicalanalysisoftheacromialheightmeasuringdevicecombinedwithnewtypeclavicularhookplateandstandardclavicularhookplateinthetreatmentofneertypeiidistalclaviclefractures AT yangna clinicalanalysisoftheacromialheightmeasuringdevicecombinedwithnewtypeclavicularhookplateandstandardclavicularhookplateinthetreatmentofneertypeiidistalclaviclefractures AT zhangkun clinicalanalysisoftheacromialheightmeasuringdevicecombinedwithnewtypeclavicularhookplateandstandardclavicularhookplateinthetreatmentofneertypeiidistalclaviclefractures AT zhuyangjun clinicalanalysisoftheacromialheightmeasuringdevicecombinedwithnewtypeclavicularhookplateandstandardclavicularhookplateinthetreatmentofneertypeiidistalclaviclefractures AT songzhe clinicalanalysisoftheacromialheightmeasuringdevicecombinedwithnewtypeclavicularhookplateandstandardclavicularhookplateinthetreatmentofneertypeiidistalclaviclefractures |