Federated Learning for Microvasculature Segmentation and Diabetic Retinopathy Classification of OCT Data
PURPOSE: To evaluate the performance of a federated learning framework for deep neural network-based retinal microvasculature segmentation and referable diabetic retinopathy (RDR) classification using OCT and OCT angiography (OCTA). DESIGN: Retrospective analysis of clinical OCT and OCTA scans of co...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9559956/ https://www.ncbi.nlm.nih.gov/pubmed/36246944 http://dx.doi.org/10.1016/j.xops.2021.100069 |
_version_ | 1784807728922755072 |
---|---|
author | Lo, Julian Yu, Timothy T. Ma, Da Zang, Pengxiao Owen, Julia P. Zhang, Qinqin Wang, Ruikang K. Beg, Mirza Faisal Lee, Aaron Y. Jia, Yali Sarunic, Marinko V. |
author_facet | Lo, Julian Yu, Timothy T. Ma, Da Zang, Pengxiao Owen, Julia P. Zhang, Qinqin Wang, Ruikang K. Beg, Mirza Faisal Lee, Aaron Y. Jia, Yali Sarunic, Marinko V. |
author_sort | Lo, Julian |
collection | PubMed |
description | PURPOSE: To evaluate the performance of a federated learning framework for deep neural network-based retinal microvasculature segmentation and referable diabetic retinopathy (RDR) classification using OCT and OCT angiography (OCTA). DESIGN: Retrospective analysis of clinical OCT and OCTA scans of control participants and patients with diabetes. PARTICIPANTS: The 153 OCTA en face images used for microvasculature segmentation were acquired from 4 OCT instruments with fields of view ranging from 2 × 2-mm to 6 × 6-mm. The 700 eyes used for RDR classification consisted of OCTA en face images and structural OCT projections acquired from 2 commercial OCT systems. METHODS: OCT angiography images used for microvasculature segmentation were delineated manually and verified by retina experts. Diabetic retinopathy (DR) severity was evaluated by retinal specialists and was condensed into 2 classes: non-RDR and RDR. The federated learning configuration was demonstrated via simulation using 4 clients for microvasculature segmentation and was compared with other collaborative training methods. Subsequently, federated learning was applied over multiple institutions for RDR classification and was compared with models trained and tested on data from the same institution (internal models) and different institutions (external models). MAIN OUTCOME MEASURES: For microvasculature segmentation, we measured the accuracy and Dice similarity coefficient (DSC). For severity classification, we measured accuracy, area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve, balanced accuracy, F1 score, sensitivity, and specificity. RESULTS: For both applications, federated learning achieved similar performance as internal models. Specifically, for microvasculature segmentation, the federated learning model achieved similar performance (mean DSC across all test sets, 0.793) as models trained on a fully centralized dataset (mean DSC, 0.807). For RDR classification, federated learning achieved a mean AUROC of 0.954 and 0.960; the internal models attained a mean AUROC of 0.956 and 0.973. Similar results are reflected in the other calculated evaluation metrics. CONCLUSIONS: Federated learning showed similar results to traditional deep learning in both applications of segmentation and classification, while maintaining data privacy. Evaluation metrics highlight the potential of collaborative learning for increasing domain diversity and the generalizability of models used for the classification of OCT data. |
format | Online Article Text |
id | pubmed-9559956 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-95599562022-10-14 Federated Learning for Microvasculature Segmentation and Diabetic Retinopathy Classification of OCT Data Lo, Julian Yu, Timothy T. Ma, Da Zang, Pengxiao Owen, Julia P. Zhang, Qinqin Wang, Ruikang K. Beg, Mirza Faisal Lee, Aaron Y. Jia, Yali Sarunic, Marinko V. Ophthalmol Sci The VSI: Artificial Intelligence and Big Data Collection PURPOSE: To evaluate the performance of a federated learning framework for deep neural network-based retinal microvasculature segmentation and referable diabetic retinopathy (RDR) classification using OCT and OCT angiography (OCTA). DESIGN: Retrospective analysis of clinical OCT and OCTA scans of control participants and patients with diabetes. PARTICIPANTS: The 153 OCTA en face images used for microvasculature segmentation were acquired from 4 OCT instruments with fields of view ranging from 2 × 2-mm to 6 × 6-mm. The 700 eyes used for RDR classification consisted of OCTA en face images and structural OCT projections acquired from 2 commercial OCT systems. METHODS: OCT angiography images used for microvasculature segmentation were delineated manually and verified by retina experts. Diabetic retinopathy (DR) severity was evaluated by retinal specialists and was condensed into 2 classes: non-RDR and RDR. The federated learning configuration was demonstrated via simulation using 4 clients for microvasculature segmentation and was compared with other collaborative training methods. Subsequently, federated learning was applied over multiple institutions for RDR classification and was compared with models trained and tested on data from the same institution (internal models) and different institutions (external models). MAIN OUTCOME MEASURES: For microvasculature segmentation, we measured the accuracy and Dice similarity coefficient (DSC). For severity classification, we measured accuracy, area under the receiver operating characteristic curve (AUROC), area under the precision-recall curve, balanced accuracy, F1 score, sensitivity, and specificity. RESULTS: For both applications, federated learning achieved similar performance as internal models. Specifically, for microvasculature segmentation, the federated learning model achieved similar performance (mean DSC across all test sets, 0.793) as models trained on a fully centralized dataset (mean DSC, 0.807). For RDR classification, federated learning achieved a mean AUROC of 0.954 and 0.960; the internal models attained a mean AUROC of 0.956 and 0.973. Similar results are reflected in the other calculated evaluation metrics. CONCLUSIONS: Federated learning showed similar results to traditional deep learning in both applications of segmentation and classification, while maintaining data privacy. Evaluation metrics highlight the potential of collaborative learning for increasing domain diversity and the generalizability of models used for the classification of OCT data. Elsevier 2021-10-08 /pmc/articles/PMC9559956/ /pubmed/36246944 http://dx.doi.org/10.1016/j.xops.2021.100069 Text en © 2021 by the American Academy of Ophthalmology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | The VSI: Artificial Intelligence and Big Data Collection Lo, Julian Yu, Timothy T. Ma, Da Zang, Pengxiao Owen, Julia P. Zhang, Qinqin Wang, Ruikang K. Beg, Mirza Faisal Lee, Aaron Y. Jia, Yali Sarunic, Marinko V. Federated Learning for Microvasculature Segmentation and Diabetic Retinopathy Classification of OCT Data |
title | Federated Learning for Microvasculature Segmentation and Diabetic Retinopathy Classification of OCT Data |
title_full | Federated Learning for Microvasculature Segmentation and Diabetic Retinopathy Classification of OCT Data |
title_fullStr | Federated Learning for Microvasculature Segmentation and Diabetic Retinopathy Classification of OCT Data |
title_full_unstemmed | Federated Learning for Microvasculature Segmentation and Diabetic Retinopathy Classification of OCT Data |
title_short | Federated Learning for Microvasculature Segmentation and Diabetic Retinopathy Classification of OCT Data |
title_sort | federated learning for microvasculature segmentation and diabetic retinopathy classification of oct data |
topic | The VSI: Artificial Intelligence and Big Data Collection |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9559956/ https://www.ncbi.nlm.nih.gov/pubmed/36246944 http://dx.doi.org/10.1016/j.xops.2021.100069 |
work_keys_str_mv | AT lojulian federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata AT yutimothyt federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata AT mada federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata AT zangpengxiao federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata AT owenjuliap federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata AT zhangqinqin federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata AT wangruikangk federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata AT begmirzafaisal federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata AT leeaarony federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata AT jiayali federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata AT sarunicmarinkov federatedlearningformicrovasculaturesegmentationanddiabeticretinopathyclassificationofoctdata |