Cargando…

Optimized low-dose positron emission tomography/computed tomography schemes in pediatric tumor patients: a randomized clinical trial

BACKGROUND: It’s clinically relevant to reduce the radiation dose to children while ensuring their positron emission tomography/computed tomography (PET/CT) image quality. The optimal protocol for whole-body PET/CT imaging in children (non-model) has been less studied. In this study, we investigated...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Songke, Qian, Zhongjie, Liu, Hongli, Fan, Rongqin, Long, Xueqin, Li, Bo, Zhang, Qian, Wang, Yumei, Cao, Lin, Zhou, Rui, Hou, Dingyou, Gao, Daiqiang, Liu, Lisheng, Chen, Xiaoliang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9561506/
https://www.ncbi.nlm.nih.gov/pubmed/36247895
http://dx.doi.org/10.21037/tp-22-371
_version_ 1784807960429461504
author Yu, Songke
Qian, Zhongjie
Liu, Hongli
Fan, Rongqin
Long, Xueqin
Li, Bo
Zhang, Qian
Wang, Yumei
Cao, Lin
Zhou, Rui
Hou, Dingyou
Gao, Daiqiang
Liu, Lisheng
Chen, Xiaoliang
author_facet Yu, Songke
Qian, Zhongjie
Liu, Hongli
Fan, Rongqin
Long, Xueqin
Li, Bo
Zhang, Qian
Wang, Yumei
Cao, Lin
Zhou, Rui
Hou, Dingyou
Gao, Daiqiang
Liu, Lisheng
Chen, Xiaoliang
author_sort Yu, Songke
collection PubMed
description BACKGROUND: It’s clinically relevant to reduce the radiation dose to children while ensuring their positron emission tomography/computed tomography (PET/CT) image quality. The optimal protocol for whole-body PET/CT imaging in children (non-model) has been less studied. In this study, we investigated the optimal protocol for PET/CT imaging of pediatric oncology by analyzing the radiation dose and image quality in18F-fluoro-2-deoxy-D-glucose ((18)F-FDG) PET/CT imaging of children with oncology. METHODS: One hundred children with tumors who underwent (18)F-FDG PET/CT were included. CT grouping: randomly divided into 18 groups A–R according to the combination of three parameters: tube voltage (80/120 kV), automatic milliamp range (20–39/40–59/60–80 mA), and noise index (NI) (8/12/14). PET grouping: randomly divided into 9 groups a–i according to the combination of two parameters: the pharmaceuticals injection dose (0.08/0.12/0.15 mCi/kg) and time per bed (120/150/180 s). The effective radiation dose (ED) was calculated separately for each group and the image quality of CT and PET was evaluated subjectively using standard deviation (SD) and coefficient of variation (CV) objective evaluation and 5-point evaluation method, respectively. RESULTS: Ninety-seven images in CT and 57 images in PET were included. The best quality of CT images was in group K (120 kV/40–59 mA/8); there are 9 groups had good image quality and lower dose length product (DLP) than group K (SD ±10), while the difference in DLP between groups was large. The Kruskal-Wallis (K-W) test showed that the difference in image quality between the 9 groups was not statistically significant. The best PET image quality was in group i [0.15 (mCi/kg)/180 s]; there are four groups had good image quality and lower ED(PET) than group i (CV ±3.5%), while the difference in ED(PET) between groups was large (4.4–6.5 mSv), and the K-W test showed that the difference in image quality between the four groups was not statistically significant (P>0.05), with the lowest ED(PET) being in the g group. CONCLUSIONS: The optimal protocols for CT scanning and PET imaging in this experiment were group H (80 kV/40–59 mA/14) and group g [0.08 (mCi/kg)/180 s], respectively. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR2200061386.
format Online
Article
Text
id pubmed-9561506
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-95615062022-10-15 Optimized low-dose positron emission tomography/computed tomography schemes in pediatric tumor patients: a randomized clinical trial Yu, Songke Qian, Zhongjie Liu, Hongli Fan, Rongqin Long, Xueqin Li, Bo Zhang, Qian Wang, Yumei Cao, Lin Zhou, Rui Hou, Dingyou Gao, Daiqiang Liu, Lisheng Chen, Xiaoliang Transl Pediatr Original Article BACKGROUND: It’s clinically relevant to reduce the radiation dose to children while ensuring their positron emission tomography/computed tomography (PET/CT) image quality. The optimal protocol for whole-body PET/CT imaging in children (non-model) has been less studied. In this study, we investigated the optimal protocol for PET/CT imaging of pediatric oncology by analyzing the radiation dose and image quality in18F-fluoro-2-deoxy-D-glucose ((18)F-FDG) PET/CT imaging of children with oncology. METHODS: One hundred children with tumors who underwent (18)F-FDG PET/CT were included. CT grouping: randomly divided into 18 groups A–R according to the combination of three parameters: tube voltage (80/120 kV), automatic milliamp range (20–39/40–59/60–80 mA), and noise index (NI) (8/12/14). PET grouping: randomly divided into 9 groups a–i according to the combination of two parameters: the pharmaceuticals injection dose (0.08/0.12/0.15 mCi/kg) and time per bed (120/150/180 s). The effective radiation dose (ED) was calculated separately for each group and the image quality of CT and PET was evaluated subjectively using standard deviation (SD) and coefficient of variation (CV) objective evaluation and 5-point evaluation method, respectively. RESULTS: Ninety-seven images in CT and 57 images in PET were included. The best quality of CT images was in group K (120 kV/40–59 mA/8); there are 9 groups had good image quality and lower dose length product (DLP) than group K (SD ±10), while the difference in DLP between groups was large. The Kruskal-Wallis (K-W) test showed that the difference in image quality between the 9 groups was not statistically significant. The best PET image quality was in group i [0.15 (mCi/kg)/180 s]; there are four groups had good image quality and lower ED(PET) than group i (CV ±3.5%), while the difference in ED(PET) between groups was large (4.4–6.5 mSv), and the K-W test showed that the difference in image quality between the four groups was not statistically significant (P>0.05), with the lowest ED(PET) being in the g group. CONCLUSIONS: The optimal protocols for CT scanning and PET imaging in this experiment were group H (80 kV/40–59 mA/14) and group g [0.08 (mCi/kg)/180 s], respectively. TRIAL REGISTRATION: Chinese Clinical Trial Registry ChiCTR2200061386. AME Publishing Company 2022-09 /pmc/articles/PMC9561506/ /pubmed/36247895 http://dx.doi.org/10.21037/tp-22-371 Text en 2022 Translational Pediatrics. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Yu, Songke
Qian, Zhongjie
Liu, Hongli
Fan, Rongqin
Long, Xueqin
Li, Bo
Zhang, Qian
Wang, Yumei
Cao, Lin
Zhou, Rui
Hou, Dingyou
Gao, Daiqiang
Liu, Lisheng
Chen, Xiaoliang
Optimized low-dose positron emission tomography/computed tomography schemes in pediatric tumor patients: a randomized clinical trial
title Optimized low-dose positron emission tomography/computed tomography schemes in pediatric tumor patients: a randomized clinical trial
title_full Optimized low-dose positron emission tomography/computed tomography schemes in pediatric tumor patients: a randomized clinical trial
title_fullStr Optimized low-dose positron emission tomography/computed tomography schemes in pediatric tumor patients: a randomized clinical trial
title_full_unstemmed Optimized low-dose positron emission tomography/computed tomography schemes in pediatric tumor patients: a randomized clinical trial
title_short Optimized low-dose positron emission tomography/computed tomography schemes in pediatric tumor patients: a randomized clinical trial
title_sort optimized low-dose positron emission tomography/computed tomography schemes in pediatric tumor patients: a randomized clinical trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9561506/
https://www.ncbi.nlm.nih.gov/pubmed/36247895
http://dx.doi.org/10.21037/tp-22-371
work_keys_str_mv AT yusongke optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT qianzhongjie optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT liuhongli optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT fanrongqin optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT longxueqin optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT libo optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT zhangqian optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT wangyumei optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT caolin optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT zhourui optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT houdingyou optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT gaodaiqiang optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT liulisheng optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial
AT chenxiaoliang optimizedlowdosepositronemissiontomographycomputedtomographyschemesinpediatrictumorpatientsarandomizedclinicaltrial