Cargando…
Virtual Reality Oculokinetic Perimetry Test Reproducibility and Relationship to Conventional Perimetry and OCT
PURPOSE: Vivid Vision Perimetry (VVP; Vivid Vision, Inc) is a novel method for performing in-office and home-based visual field assessment using a virtual reality platform and oculokinetic perimetry. Here we examine the reproducibility of VVP Swift and compare results with conventional standard auto...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9562375/ https://www.ncbi.nlm.nih.gov/pubmed/36276927 http://dx.doi.org/10.1016/j.xops.2021.100105 |
_version_ | 1784808158116446208 |
---|---|
author | Greenfield, Jason A. Deiner, Michael Nguyen, Anwell Wollstein, Gadi Damato, Bertil Backus, Benjamin T. Wu, Mengfei Schuman, Joel S. Ou, Yvonne |
author_facet | Greenfield, Jason A. Deiner, Michael Nguyen, Anwell Wollstein, Gadi Damato, Bertil Backus, Benjamin T. Wu, Mengfei Schuman, Joel S. Ou, Yvonne |
author_sort | Greenfield, Jason A. |
collection | PubMed |
description | PURPOSE: Vivid Vision Perimetry (VVP; Vivid Vision, Inc) is a novel method for performing in-office and home-based visual field assessment using a virtual reality platform and oculokinetic perimetry. Here we examine the reproducibility of VVP Swift and compare results with conventional standard automated perimetry (SAP) and spectral-domain (SD) OCT. DESIGN: Cross-sectional study. PARTICIPANTS: Fourteen eyes of 7 patients with open-angle glaucoma (OAG) (average age, 64.6 years; 29% women) and 10 eyes of 5 patients with suspected glaucoma (average age, 61.8 years; 40% women) were enrolled. METHODS: Patients with OAG and suspected glaucoma were enrolled prospectively and underwent 2 VVP Swift examinations. Results were compared with 1 conventional SAP examination (Humphrey Visual Field [HVF]; Zeiss) and 1 SD OCT examination. MAIN OUTCOME MEASURES: Mean sensitivity (in decibels) obtained for each eye in 2 VVP Swift test sessions and a conventional SAP examination, thickness of the retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) for the SD OCT examination, and mean test durations of the VVP Swift and SAP examinations. RESULTS: The mean test duration of VVP Swift in both eyes (8.5 minutes) was significantly shorter (P < 0.001) than SAP (12.2 minutes). The average absolute difference of the mean sensitivity between the 2 VVP Swift sessions was found to be 0.73 dB (95% confidence interval [CI], 0.40–1.06). A statistically significant association was found between average mean sensitivity measurements from the VVP and mean deviation (MD) measurements obtained by the HVF with a Pearson correlation coefficient of 0.86 (95% CI, 0.70–0.94; P < 0.001). Mean visual sensitivity measurements from the VVP Swift test were significantly associated with average RNFL thickness (r = 0.66; P = 0.014) and GCC thickness (r = 0.63; P = 0.02), whereas the correlation coefficients between HVF MD and RNFL and GCC were 0.86 (P < 0.001) and 0.83 (P < 0.001), respectively. CONCLUSIONS: Our results demonstrated that the VVP Swift test can generate reproducible results and is comparable with conventional SAP. This suggests that the device can be used by clinicians to assess visual function in glaucoma. |
format | Online Article Text |
id | pubmed-9562375 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-95623752022-10-21 Virtual Reality Oculokinetic Perimetry Test Reproducibility and Relationship to Conventional Perimetry and OCT Greenfield, Jason A. Deiner, Michael Nguyen, Anwell Wollstein, Gadi Damato, Bertil Backus, Benjamin T. Wu, Mengfei Schuman, Joel S. Ou, Yvonne Ophthalmol Sci Original Article PURPOSE: Vivid Vision Perimetry (VVP; Vivid Vision, Inc) is a novel method for performing in-office and home-based visual field assessment using a virtual reality platform and oculokinetic perimetry. Here we examine the reproducibility of VVP Swift and compare results with conventional standard automated perimetry (SAP) and spectral-domain (SD) OCT. DESIGN: Cross-sectional study. PARTICIPANTS: Fourteen eyes of 7 patients with open-angle glaucoma (OAG) (average age, 64.6 years; 29% women) and 10 eyes of 5 patients with suspected glaucoma (average age, 61.8 years; 40% women) were enrolled. METHODS: Patients with OAG and suspected glaucoma were enrolled prospectively and underwent 2 VVP Swift examinations. Results were compared with 1 conventional SAP examination (Humphrey Visual Field [HVF]; Zeiss) and 1 SD OCT examination. MAIN OUTCOME MEASURES: Mean sensitivity (in decibels) obtained for each eye in 2 VVP Swift test sessions and a conventional SAP examination, thickness of the retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC) for the SD OCT examination, and mean test durations of the VVP Swift and SAP examinations. RESULTS: The mean test duration of VVP Swift in both eyes (8.5 minutes) was significantly shorter (P < 0.001) than SAP (12.2 minutes). The average absolute difference of the mean sensitivity between the 2 VVP Swift sessions was found to be 0.73 dB (95% confidence interval [CI], 0.40–1.06). A statistically significant association was found between average mean sensitivity measurements from the VVP and mean deviation (MD) measurements obtained by the HVF with a Pearson correlation coefficient of 0.86 (95% CI, 0.70–0.94; P < 0.001). Mean visual sensitivity measurements from the VVP Swift test were significantly associated with average RNFL thickness (r = 0.66; P = 0.014) and GCC thickness (r = 0.63; P = 0.02), whereas the correlation coefficients between HVF MD and RNFL and GCC were 0.86 (P < 0.001) and 0.83 (P < 0.001), respectively. CONCLUSIONS: Our results demonstrated that the VVP Swift test can generate reproducible results and is comparable with conventional SAP. This suggests that the device can be used by clinicians to assess visual function in glaucoma. Elsevier 2021-12-21 /pmc/articles/PMC9562375/ /pubmed/36276927 http://dx.doi.org/10.1016/j.xops.2021.100105 Text en © 2021 by the American Academy of Ophthalmology. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Original Article Greenfield, Jason A. Deiner, Michael Nguyen, Anwell Wollstein, Gadi Damato, Bertil Backus, Benjamin T. Wu, Mengfei Schuman, Joel S. Ou, Yvonne Virtual Reality Oculokinetic Perimetry Test Reproducibility and Relationship to Conventional Perimetry and OCT |
title | Virtual Reality Oculokinetic Perimetry Test Reproducibility and Relationship to Conventional Perimetry and OCT |
title_full | Virtual Reality Oculokinetic Perimetry Test Reproducibility and Relationship to Conventional Perimetry and OCT |
title_fullStr | Virtual Reality Oculokinetic Perimetry Test Reproducibility and Relationship to Conventional Perimetry and OCT |
title_full_unstemmed | Virtual Reality Oculokinetic Perimetry Test Reproducibility and Relationship to Conventional Perimetry and OCT |
title_short | Virtual Reality Oculokinetic Perimetry Test Reproducibility and Relationship to Conventional Perimetry and OCT |
title_sort | virtual reality oculokinetic perimetry test reproducibility and relationship to conventional perimetry and oct |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9562375/ https://www.ncbi.nlm.nih.gov/pubmed/36276927 http://dx.doi.org/10.1016/j.xops.2021.100105 |
work_keys_str_mv | AT greenfieldjasona virtualrealityoculokineticperimetrytestreproducibilityandrelationshiptoconventionalperimetryandoct AT deinermichael virtualrealityoculokineticperimetrytestreproducibilityandrelationshiptoconventionalperimetryandoct AT nguyenanwell virtualrealityoculokineticperimetrytestreproducibilityandrelationshiptoconventionalperimetryandoct AT wollsteingadi virtualrealityoculokineticperimetrytestreproducibilityandrelationshiptoconventionalperimetryandoct AT damatobertil virtualrealityoculokineticperimetrytestreproducibilityandrelationshiptoconventionalperimetryandoct AT backusbenjamint virtualrealityoculokineticperimetrytestreproducibilityandrelationshiptoconventionalperimetryandoct AT wumengfei virtualrealityoculokineticperimetrytestreproducibilityandrelationshiptoconventionalperimetryandoct AT schumanjoels virtualrealityoculokineticperimetrytestreproducibilityandrelationshiptoconventionalperimetryandoct AT ouyvonne virtualrealityoculokineticperimetrytestreproducibilityandrelationshiptoconventionalperimetryandoct |