Cargando…
Reliability of TMS measurements using conventional hand-hold method with different numbers of stimuli for tibialis anterior muscle in healthy adults
Objective: The objective of this study was to determine the reliability of corticomotor excitability measurements using the conventional hand-hold transcranial magnetic stimulation (TMS) method for the tibialis anterior (TA) muscle in healthy adults and the number of stimuli required for reliable as...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9563236/ https://www.ncbi.nlm.nih.gov/pubmed/36247728 http://dx.doi.org/10.3389/fncir.2022.986669 |
_version_ | 1784808353169408000 |
---|---|
author | Su, Bin Jia, Yanbing Zhang, Li Li, Duo Shen, Qianqian Wang, Chun Chen, Yating Gao, Fanglan Wei, Jing Huang, Guilan Liu, Hao Wang, Lin |
author_facet | Su, Bin Jia, Yanbing Zhang, Li Li, Duo Shen, Qianqian Wang, Chun Chen, Yating Gao, Fanglan Wei, Jing Huang, Guilan Liu, Hao Wang, Lin |
author_sort | Su, Bin |
collection | PubMed |
description | Objective: The objective of this study was to determine the reliability of corticomotor excitability measurements using the conventional hand-hold transcranial magnetic stimulation (TMS) method for the tibialis anterior (TA) muscle in healthy adults and the number of stimuli required for reliable assessment. Methods: Forty healthy adults participated in three repeated sessions of corticomotor excitability assessment in terms of resting motor threshold (rMT), slope of recruitment curve (RC), peak motor evoked potential amplitude (pMEP), and MEP latency using conventional TMS method. The first two sessions were conducted with a rest interval of 1 h, and the last session was conducted 7–10 days afterward. With the exception of rMT, the other three outcomes measure elicited with the block of first 3–10 stimuli were analyzed respectively. The within-day (session 1 vs. 2) and between-day (session 1 vs. 3) reliability for all four outcome measures were assessed using intraclass correlation coefficient (ICC), standard error of measurement, and minimum detectable difference at 95% confidence interval. Results: Good to excellent within-day and between-day reliability was found for TMS-induced outcome measures examined using 10 stimuli (ICC ≥ 0.823), except in pMEP, which showed between-day reliability at moderate level (ICC = 0.730). The number of three stimuli was adequate to achieve minimum acceptable within-day reliability for all TMS-induced parameters and between-day reliability for MEP latency. With regard to between-day reliability of RC slope and pMEP, at least seven and nine stimuli were recommended respectively. Conclusion: Our findings indicated the high reliability of corticomotor excitability measurement by TMS with adequate number of stimuli for the TA muscle in healthy adults. This result should be interpreted with caveats for the specific methodological choices, equipment setting, and the characteristics of the sample in the current study. Clinical Trial Registration: http://www.chictr.org.cn, identifier ChiCTR2100045141. |
format | Online Article Text |
id | pubmed-9563236 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-95632362022-10-15 Reliability of TMS measurements using conventional hand-hold method with different numbers of stimuli for tibialis anterior muscle in healthy adults Su, Bin Jia, Yanbing Zhang, Li Li, Duo Shen, Qianqian Wang, Chun Chen, Yating Gao, Fanglan Wei, Jing Huang, Guilan Liu, Hao Wang, Lin Front Neural Circuits Neuroscience Objective: The objective of this study was to determine the reliability of corticomotor excitability measurements using the conventional hand-hold transcranial magnetic stimulation (TMS) method for the tibialis anterior (TA) muscle in healthy adults and the number of stimuli required for reliable assessment. Methods: Forty healthy adults participated in three repeated sessions of corticomotor excitability assessment in terms of resting motor threshold (rMT), slope of recruitment curve (RC), peak motor evoked potential amplitude (pMEP), and MEP latency using conventional TMS method. The first two sessions were conducted with a rest interval of 1 h, and the last session was conducted 7–10 days afterward. With the exception of rMT, the other three outcomes measure elicited with the block of first 3–10 stimuli were analyzed respectively. The within-day (session 1 vs. 2) and between-day (session 1 vs. 3) reliability for all four outcome measures were assessed using intraclass correlation coefficient (ICC), standard error of measurement, and minimum detectable difference at 95% confidence interval. Results: Good to excellent within-day and between-day reliability was found for TMS-induced outcome measures examined using 10 stimuli (ICC ≥ 0.823), except in pMEP, which showed between-day reliability at moderate level (ICC = 0.730). The number of three stimuli was adequate to achieve minimum acceptable within-day reliability for all TMS-induced parameters and between-day reliability for MEP latency. With regard to between-day reliability of RC slope and pMEP, at least seven and nine stimuli were recommended respectively. Conclusion: Our findings indicated the high reliability of corticomotor excitability measurement by TMS with adequate number of stimuli for the TA muscle in healthy adults. This result should be interpreted with caveats for the specific methodological choices, equipment setting, and the characteristics of the sample in the current study. Clinical Trial Registration: http://www.chictr.org.cn, identifier ChiCTR2100045141. Frontiers Media S.A. 2022-09-30 /pmc/articles/PMC9563236/ /pubmed/36247728 http://dx.doi.org/10.3389/fncir.2022.986669 Text en Copyright © 2022 Su, Jia, Zhang, Li, Shen, Wang, Chen, Gao, Wei, Huang, Liu and Wang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Neuroscience Su, Bin Jia, Yanbing Zhang, Li Li, Duo Shen, Qianqian Wang, Chun Chen, Yating Gao, Fanglan Wei, Jing Huang, Guilan Liu, Hao Wang, Lin Reliability of TMS measurements using conventional hand-hold method with different numbers of stimuli for tibialis anterior muscle in healthy adults |
title | Reliability of TMS measurements using conventional hand-hold method with different numbers of stimuli for tibialis anterior muscle in healthy adults |
title_full | Reliability of TMS measurements using conventional hand-hold method with different numbers of stimuli for tibialis anterior muscle in healthy adults |
title_fullStr | Reliability of TMS measurements using conventional hand-hold method with different numbers of stimuli for tibialis anterior muscle in healthy adults |
title_full_unstemmed | Reliability of TMS measurements using conventional hand-hold method with different numbers of stimuli for tibialis anterior muscle in healthy adults |
title_short | Reliability of TMS measurements using conventional hand-hold method with different numbers of stimuli for tibialis anterior muscle in healthy adults |
title_sort | reliability of tms measurements using conventional hand-hold method with different numbers of stimuli for tibialis anterior muscle in healthy adults |
topic | Neuroscience |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9563236/ https://www.ncbi.nlm.nih.gov/pubmed/36247728 http://dx.doi.org/10.3389/fncir.2022.986669 |
work_keys_str_mv | AT subin reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT jiayanbing reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT zhangli reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT liduo reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT shenqianqian reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT wangchun reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT chenyating reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT gaofanglan reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT weijing reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT huangguilan reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT liuhao reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults AT wanglin reliabilityoftmsmeasurementsusingconventionalhandholdmethodwithdifferentnumbersofstimulifortibialisanteriormuscleinhealthyadults |