Cargando…
Restoration and maintenance of segment lordosis in oblique lumbar interbody fusion
PURPOSE: Restoration of the segment lordosis angle (SLA) can effectively reduce the risk of adjacent segment degeneration. This study aimed to perform a comprehensive multifactor analysis of the risk factors affecting restoration and maintenance of the SLA in oblique lumbar interbody fusion (OLIF)....
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9563436/ https://www.ncbi.nlm.nih.gov/pubmed/36242007 http://dx.doi.org/10.1186/s12891-022-05855-z |
_version_ | 1784808403915243520 |
---|---|
author | Gong, Ke Lin, Yang Wang, Zhibin Li, Feng Xiong, Wei |
author_facet | Gong, Ke Lin, Yang Wang, Zhibin Li, Feng Xiong, Wei |
author_sort | Gong, Ke |
collection | PubMed |
description | PURPOSE: Restoration of the segment lordosis angle (SLA) can effectively reduce the risk of adjacent segment degeneration. This study aimed to perform a comprehensive multifactor analysis of the risk factors affecting restoration and maintenance of the SLA in oblique lumbar interbody fusion (OLIF). METHODS: Seventy-three patients (93 segments) who underwent OLIF with posterior pedicle screw fixation due to lumbar degenerative disease between January 2015 and December 2019 were included. Radiographic parameters including the middle disc height (MDH), segment lordosis angle (SLA), cage center point ratio (CPR), cage subsidence, and L1 CT Hounsfield Unit (HU) were measured. RESULTS: The postoperative SLA increased from 3.5° to 8.7°, and decreased to 6.7° at the last follow-up. Multivariate analysis showed that preoperative SLA, CPR and cage subsidence were significantly correlated with SLA restoration. The significant correlations were between restoration of SLA with pre-operative SLA (r=-0.575, adjusted R2 = 0.323, P < 0.01) and between SLA restoration and CPR (r = 0.526, adjusted R2 = 0.268, P < 0.01). Cage subsidence was found in 12.9% (12/93) of segments and was the main factor affecting SLA loss (4.2 ± 1.0° versus 1.7 ± 2.1°, P < 0.01). Logistic regression analysis showed that CPR < 50%, L1 CT HU < 110 and cage height > preoperative MDH were risk factors for cage subsidence. Cages placed anteriorly (CPR ≥ 50%) showed a large SLA increase and lower incidence of cage subsidence than those placed posteriorly (5.9 ± 3.9° versus 4.2 ± 3.2°, P < 0.05; 1.8% versus 28.9%, P < 0.05, respectively). CONCLUSION: SLA restoration is dependent on preoperative SLA, cage subsidence and cage position in OLIF. Cage position is the key determinant of SLA restoration and placement of the cage at the anterior position (CPR ≥ 50%) can achieve better restoration of the SLA and reduce the incidence of cage subsidence. |
format | Online Article Text |
id | pubmed-9563436 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-95634362022-10-15 Restoration and maintenance of segment lordosis in oblique lumbar interbody fusion Gong, Ke Lin, Yang Wang, Zhibin Li, Feng Xiong, Wei BMC Musculoskelet Disord Research PURPOSE: Restoration of the segment lordosis angle (SLA) can effectively reduce the risk of adjacent segment degeneration. This study aimed to perform a comprehensive multifactor analysis of the risk factors affecting restoration and maintenance of the SLA in oblique lumbar interbody fusion (OLIF). METHODS: Seventy-three patients (93 segments) who underwent OLIF with posterior pedicle screw fixation due to lumbar degenerative disease between January 2015 and December 2019 were included. Radiographic parameters including the middle disc height (MDH), segment lordosis angle (SLA), cage center point ratio (CPR), cage subsidence, and L1 CT Hounsfield Unit (HU) were measured. RESULTS: The postoperative SLA increased from 3.5° to 8.7°, and decreased to 6.7° at the last follow-up. Multivariate analysis showed that preoperative SLA, CPR and cage subsidence were significantly correlated with SLA restoration. The significant correlations were between restoration of SLA with pre-operative SLA (r=-0.575, adjusted R2 = 0.323, P < 0.01) and between SLA restoration and CPR (r = 0.526, adjusted R2 = 0.268, P < 0.01). Cage subsidence was found in 12.9% (12/93) of segments and was the main factor affecting SLA loss (4.2 ± 1.0° versus 1.7 ± 2.1°, P < 0.01). Logistic regression analysis showed that CPR < 50%, L1 CT HU < 110 and cage height > preoperative MDH were risk factors for cage subsidence. Cages placed anteriorly (CPR ≥ 50%) showed a large SLA increase and lower incidence of cage subsidence than those placed posteriorly (5.9 ± 3.9° versus 4.2 ± 3.2°, P < 0.05; 1.8% versus 28.9%, P < 0.05, respectively). CONCLUSION: SLA restoration is dependent on preoperative SLA, cage subsidence and cage position in OLIF. Cage position is the key determinant of SLA restoration and placement of the cage at the anterior position (CPR ≥ 50%) can achieve better restoration of the SLA and reduce the incidence of cage subsidence. BioMed Central 2022-10-14 /pmc/articles/PMC9563436/ /pubmed/36242007 http://dx.doi.org/10.1186/s12891-022-05855-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Research Gong, Ke Lin, Yang Wang, Zhibin Li, Feng Xiong, Wei Restoration and maintenance of segment lordosis in oblique lumbar interbody fusion |
title | Restoration and maintenance of segment lordosis in oblique lumbar interbody fusion |
title_full | Restoration and maintenance of segment lordosis in oblique lumbar interbody fusion |
title_fullStr | Restoration and maintenance of segment lordosis in oblique lumbar interbody fusion |
title_full_unstemmed | Restoration and maintenance of segment lordosis in oblique lumbar interbody fusion |
title_short | Restoration and maintenance of segment lordosis in oblique lumbar interbody fusion |
title_sort | restoration and maintenance of segment lordosis in oblique lumbar interbody fusion |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9563436/ https://www.ncbi.nlm.nih.gov/pubmed/36242007 http://dx.doi.org/10.1186/s12891-022-05855-z |
work_keys_str_mv | AT gongke restorationandmaintenanceofsegmentlordosisinobliquelumbarinterbodyfusion AT linyang restorationandmaintenanceofsegmentlordosisinobliquelumbarinterbodyfusion AT wangzhibin restorationandmaintenanceofsegmentlordosisinobliquelumbarinterbodyfusion AT lifeng restorationandmaintenanceofsegmentlordosisinobliquelumbarinterbodyfusion AT xiongwei restorationandmaintenanceofsegmentlordosisinobliquelumbarinterbodyfusion |