Cargando…

Advances in Concentration Gradient Generation Approaches in a Microfluidic Device for Toxicity Analysis

This systematic review aimed to analyze the development and functionality of microfluidic concentration gradient generators (CGGs) for toxicological evaluation of different biological organisms. We searched articles using the keywords: concentration gradient generator, toxicity, and microfluidic dev...

Descripción completa

Detalles Bibliográficos
Autores principales: Valle, Nicole M. E., Nucci, Mariana P., Alves, Arielly H., Rodrigues, Luiz D., Mamani, Javier B., Oliveira, Fernando A., Lopes, Caique S., Lopes, Alexandre T., Carreño, Marcelo N. P., Gamarra, Lionel F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9563958/
https://www.ncbi.nlm.nih.gov/pubmed/36231063
http://dx.doi.org/10.3390/cells11193101
_version_ 1784808524552863744
author Valle, Nicole M. E.
Nucci, Mariana P.
Alves, Arielly H.
Rodrigues, Luiz D.
Mamani, Javier B.
Oliveira, Fernando A.
Lopes, Caique S.
Lopes, Alexandre T.
Carreño, Marcelo N. P.
Gamarra, Lionel F.
author_facet Valle, Nicole M. E.
Nucci, Mariana P.
Alves, Arielly H.
Rodrigues, Luiz D.
Mamani, Javier B.
Oliveira, Fernando A.
Lopes, Caique S.
Lopes, Alexandre T.
Carreño, Marcelo N. P.
Gamarra, Lionel F.
author_sort Valle, Nicole M. E.
collection PubMed
description This systematic review aimed to analyze the development and functionality of microfluidic concentration gradient generators (CGGs) for toxicological evaluation of different biological organisms. We searched articles using the keywords: concentration gradient generator, toxicity, and microfluidic device. Only 33 of the 352 articles found were included and examined regarding the fabrication of the microdevices, the characteristics of the CGG, the biological model, and the desired results. The main fabrication method was soft lithography, using polydimethylsiloxane (PDMS) material (91%) and SU-8 as the mold (58.3%). New technologies were applied to minimize shear and bubble problems, reduce costs, and accelerate prototyping. The Christmas tree CGG design and its variations were the most reported in the studies, as well as the convective method of generation (61%). Biological models included bacteria and nematodes for antibiotic screening, microalgae for pollutant toxicity, tumor and normal cells for, primarily, chemotherapy screening, and Zebrafish embryos for drug and metal developmental toxicity. The toxic effects of each concentration generated were evaluated mostly with imaging and microscopy techniques. This study showed an advantage of CGGs over other techniques and their applicability for several biological models. Even with soft lithography, PDMS, and Christmas tree being more popular in their respective categories, current studies aim to apply new technologies and intricate architectures to improve testing effectiveness and reduce common microfluidics problems, allowing for high applicability of toxicity tests in different medical and environmental models.
format Online
Article
Text
id pubmed-9563958
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95639582022-10-15 Advances in Concentration Gradient Generation Approaches in a Microfluidic Device for Toxicity Analysis Valle, Nicole M. E. Nucci, Mariana P. Alves, Arielly H. Rodrigues, Luiz D. Mamani, Javier B. Oliveira, Fernando A. Lopes, Caique S. Lopes, Alexandre T. Carreño, Marcelo N. P. Gamarra, Lionel F. Cells Review This systematic review aimed to analyze the development and functionality of microfluidic concentration gradient generators (CGGs) for toxicological evaluation of different biological organisms. We searched articles using the keywords: concentration gradient generator, toxicity, and microfluidic device. Only 33 of the 352 articles found were included and examined regarding the fabrication of the microdevices, the characteristics of the CGG, the biological model, and the desired results. The main fabrication method was soft lithography, using polydimethylsiloxane (PDMS) material (91%) and SU-8 as the mold (58.3%). New technologies were applied to minimize shear and bubble problems, reduce costs, and accelerate prototyping. The Christmas tree CGG design and its variations were the most reported in the studies, as well as the convective method of generation (61%). Biological models included bacteria and nematodes for antibiotic screening, microalgae for pollutant toxicity, tumor and normal cells for, primarily, chemotherapy screening, and Zebrafish embryos for drug and metal developmental toxicity. The toxic effects of each concentration generated were evaluated mostly with imaging and microscopy techniques. This study showed an advantage of CGGs over other techniques and their applicability for several biological models. Even with soft lithography, PDMS, and Christmas tree being more popular in their respective categories, current studies aim to apply new technologies and intricate architectures to improve testing effectiveness and reduce common microfluidics problems, allowing for high applicability of toxicity tests in different medical and environmental models. MDPI 2022-10-01 /pmc/articles/PMC9563958/ /pubmed/36231063 http://dx.doi.org/10.3390/cells11193101 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Review
Valle, Nicole M. E.
Nucci, Mariana P.
Alves, Arielly H.
Rodrigues, Luiz D.
Mamani, Javier B.
Oliveira, Fernando A.
Lopes, Caique S.
Lopes, Alexandre T.
Carreño, Marcelo N. P.
Gamarra, Lionel F.
Advances in Concentration Gradient Generation Approaches in a Microfluidic Device for Toxicity Analysis
title Advances in Concentration Gradient Generation Approaches in a Microfluidic Device for Toxicity Analysis
title_full Advances in Concentration Gradient Generation Approaches in a Microfluidic Device for Toxicity Analysis
title_fullStr Advances in Concentration Gradient Generation Approaches in a Microfluidic Device for Toxicity Analysis
title_full_unstemmed Advances in Concentration Gradient Generation Approaches in a Microfluidic Device for Toxicity Analysis
title_short Advances in Concentration Gradient Generation Approaches in a Microfluidic Device for Toxicity Analysis
title_sort advances in concentration gradient generation approaches in a microfluidic device for toxicity analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9563958/
https://www.ncbi.nlm.nih.gov/pubmed/36231063
http://dx.doi.org/10.3390/cells11193101
work_keys_str_mv AT vallenicoleme advancesinconcentrationgradientgenerationapproachesinamicrofluidicdevicefortoxicityanalysis
AT nuccimarianap advancesinconcentrationgradientgenerationapproachesinamicrofluidicdevicefortoxicityanalysis
AT alvesariellyh advancesinconcentrationgradientgenerationapproachesinamicrofluidicdevicefortoxicityanalysis
AT rodriguesluizd advancesinconcentrationgradientgenerationapproachesinamicrofluidicdevicefortoxicityanalysis
AT mamanijavierb advancesinconcentrationgradientgenerationapproachesinamicrofluidicdevicefortoxicityanalysis
AT oliveirafernandoa advancesinconcentrationgradientgenerationapproachesinamicrofluidicdevicefortoxicityanalysis
AT lopescaiques advancesinconcentrationgradientgenerationapproachesinamicrofluidicdevicefortoxicityanalysis
AT lopesalexandret advancesinconcentrationgradientgenerationapproachesinamicrofluidicdevicefortoxicityanalysis
AT carrenomarcelonp advancesinconcentrationgradientgenerationapproachesinamicrofluidicdevicefortoxicityanalysis
AT gamarralionelf advancesinconcentrationgradientgenerationapproachesinamicrofluidicdevicefortoxicityanalysis