Cargando…
On the Determination of Cr(VI) in Cr(III)-Rich Particulates: From the Failure of Official Methods to the Development of an Alternative Protocol
The goals of this work are the evaluation of the performances of official methods in the challenging determination of Cr(VI) in Cr(III)-rich particulate matter, and the development of a novel and robust analytical protocol for this issue. A liquid chromatography inductively coupled plasma mass spect...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9564694/ https://www.ncbi.nlm.nih.gov/pubmed/36231411 http://dx.doi.org/10.3390/ijerph191912111 |
_version_ | 1784808708582146048 |
---|---|
author | Spinazzè, Andrea Spanu, Davide Della Bella, Pietro Corti, Cristina Borghi, Francesca Fanti, Giacomo Cattaneo, Andrea Wise, William Robert Davis, Stefan John Cavallo, Domenico Maria Recchia, Sandro |
author_facet | Spinazzè, Andrea Spanu, Davide Della Bella, Pietro Corti, Cristina Borghi, Francesca Fanti, Giacomo Cattaneo, Andrea Wise, William Robert Davis, Stefan John Cavallo, Domenico Maria Recchia, Sandro |
author_sort | Spinazzè, Andrea |
collection | PubMed |
description | The goals of this work are the evaluation of the performances of official methods in the challenging determination of Cr(VI) in Cr(III)-rich particulate matter, and the development of a novel and robust analytical protocol for this issue. A liquid chromatography inductively coupled plasma mass spectrometry apparatus (LC-ICP-MS), together with an isotope-enriched spike addition technique, was used to allow the study of Cr(III)/Cr(VI) interconversions during the extraction step. An original separation strategy based on Cr(OH)(3) head-column stacking was developed to tolerate high concentrations of Cr(III) (up to 10 mg/kg, with a Cr(VI) limit of detection of 0.51 µg/kg) without the need of any sample pretreatment. After observing, the official extraction protocols always yield false positive values in the challenging situation of particulate matter of leather industries (where huge amounts of Cr(III) are present), a new extraction strategy was developed. The novel procedure involves a 48-h extraction at room temperature using a pH-8 phosphate buffer, which demonstrated that no Cr(III)/Cr(VI) interconversions occur during this phase. To get rid of any possible interference caused by co-extracted substances, the measurement of the redox potential, together with the addition of a Fe(II)/Fe(III) redox buffer was performed to fix chromium speciation during the overall analytical protocol. |
format | Online Article Text |
id | pubmed-9564694 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95646942022-10-15 On the Determination of Cr(VI) in Cr(III)-Rich Particulates: From the Failure of Official Methods to the Development of an Alternative Protocol Spinazzè, Andrea Spanu, Davide Della Bella, Pietro Corti, Cristina Borghi, Francesca Fanti, Giacomo Cattaneo, Andrea Wise, William Robert Davis, Stefan John Cavallo, Domenico Maria Recchia, Sandro Int J Environ Res Public Health Article The goals of this work are the evaluation of the performances of official methods in the challenging determination of Cr(VI) in Cr(III)-rich particulate matter, and the development of a novel and robust analytical protocol for this issue. A liquid chromatography inductively coupled plasma mass spectrometry apparatus (LC-ICP-MS), together with an isotope-enriched spike addition technique, was used to allow the study of Cr(III)/Cr(VI) interconversions during the extraction step. An original separation strategy based on Cr(OH)(3) head-column stacking was developed to tolerate high concentrations of Cr(III) (up to 10 mg/kg, with a Cr(VI) limit of detection of 0.51 µg/kg) without the need of any sample pretreatment. After observing, the official extraction protocols always yield false positive values in the challenging situation of particulate matter of leather industries (where huge amounts of Cr(III) are present), a new extraction strategy was developed. The novel procedure involves a 48-h extraction at room temperature using a pH-8 phosphate buffer, which demonstrated that no Cr(III)/Cr(VI) interconversions occur during this phase. To get rid of any possible interference caused by co-extracted substances, the measurement of the redox potential, together with the addition of a Fe(II)/Fe(III) redox buffer was performed to fix chromium speciation during the overall analytical protocol. MDPI 2022-09-24 /pmc/articles/PMC9564694/ /pubmed/36231411 http://dx.doi.org/10.3390/ijerph191912111 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Spinazzè, Andrea Spanu, Davide Della Bella, Pietro Corti, Cristina Borghi, Francesca Fanti, Giacomo Cattaneo, Andrea Wise, William Robert Davis, Stefan John Cavallo, Domenico Maria Recchia, Sandro On the Determination of Cr(VI) in Cr(III)-Rich Particulates: From the Failure of Official Methods to the Development of an Alternative Protocol |
title | On the Determination of Cr(VI) in Cr(III)-Rich Particulates: From the Failure of Official Methods to the Development of an Alternative Protocol |
title_full | On the Determination of Cr(VI) in Cr(III)-Rich Particulates: From the Failure of Official Methods to the Development of an Alternative Protocol |
title_fullStr | On the Determination of Cr(VI) in Cr(III)-Rich Particulates: From the Failure of Official Methods to the Development of an Alternative Protocol |
title_full_unstemmed | On the Determination of Cr(VI) in Cr(III)-Rich Particulates: From the Failure of Official Methods to the Development of an Alternative Protocol |
title_short | On the Determination of Cr(VI) in Cr(III)-Rich Particulates: From the Failure of Official Methods to the Development of an Alternative Protocol |
title_sort | on the determination of cr(vi) in cr(iii)-rich particulates: from the failure of official methods to the development of an alternative protocol |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9564694/ https://www.ncbi.nlm.nih.gov/pubmed/36231411 http://dx.doi.org/10.3390/ijerph191912111 |
work_keys_str_mv | AT spinazzeandrea onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol AT spanudavide onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol AT dellabellapietro onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol AT corticristina onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol AT borghifrancesca onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol AT fantigiacomo onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol AT cattaneoandrea onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol AT wisewilliamrobert onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol AT davisstefanjohn onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol AT cavallodomenicomaria onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol AT recchiasandro onthedeterminationofcrviincriiirichparticulatesfromthefailureofofficialmethodstothedevelopmentofanalternativeprotocol |