Cargando…
A Temperature Imaging Method for Multi-Chip High Power LEDs Based on the Magnetic Nanoparticle Thermometer
In this study, a temperature imaging method based on a magnetic nanoparticle thermometer is proposed and evaluated. We first constructed a new model for finding the single temperature of magnetic nanoparticles with core size distribution. Specifically, we employed an air-core coil as a magnetic prob...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9565439/ https://www.ncbi.nlm.nih.gov/pubmed/36234408 http://dx.doi.org/10.3390/nano12193280 |
_version_ | 1784808890239549440 |
---|---|
author | Du, Zhongzhou Hu, Bin Ye, Na Sun, Yi Zhang, Haochen Bai, Shi |
author_facet | Du, Zhongzhou Hu, Bin Ye, Na Sun, Yi Zhang, Haochen Bai, Shi |
author_sort | Du, Zhongzhou |
collection | PubMed |
description | In this study, a temperature imaging method based on a magnetic nanoparticle thermometer is proposed and evaluated. We first constructed a new model for finding the single temperature of magnetic nanoparticles with core size distribution. Specifically, we employed an air-core coil as a magnetic probe, which measured the magnetization of magnetic nanoparticles (MNPs). We then constructed a relation between the output signal of an air-core coil in the direction of the geometric center axis and the magnetization of the MNPs in a 2-D imaging area based on the magnetic dipole theory. Once this was achieved, we established a temperature imaging model by utilizing Green function as the convolution kernel, which describes the distance relationship between MNPs and the geometric center axis of the air-cored coil. After this, we calculated the harmonic distribution by a deconvolution algorithm and determined the temperature of the MNPs at different positions based on the model of harmonic amplitude and temperature, resulting in the 2-D temperature distribution. The simulation proved that the model and method of 2-D temperature distribution measurement could theoretically be acceptable. In the experiment, the 2-D temperature distribution of multi-chip power LEDs was measured accurately by a homemade system, thus demonstrating the feasibility of the proposed method for temperature imaging. This method is expected to provide a new solution for measuring the internal temperature distribution of opaque objects under extreme conditions. |
format | Online Article Text |
id | pubmed-9565439 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95654392022-10-15 A Temperature Imaging Method for Multi-Chip High Power LEDs Based on the Magnetic Nanoparticle Thermometer Du, Zhongzhou Hu, Bin Ye, Na Sun, Yi Zhang, Haochen Bai, Shi Nanomaterials (Basel) Article In this study, a temperature imaging method based on a magnetic nanoparticle thermometer is proposed and evaluated. We first constructed a new model for finding the single temperature of magnetic nanoparticles with core size distribution. Specifically, we employed an air-core coil as a magnetic probe, which measured the magnetization of magnetic nanoparticles (MNPs). We then constructed a relation between the output signal of an air-core coil in the direction of the geometric center axis and the magnetization of the MNPs in a 2-D imaging area based on the magnetic dipole theory. Once this was achieved, we established a temperature imaging model by utilizing Green function as the convolution kernel, which describes the distance relationship between MNPs and the geometric center axis of the air-cored coil. After this, we calculated the harmonic distribution by a deconvolution algorithm and determined the temperature of the MNPs at different positions based on the model of harmonic amplitude and temperature, resulting in the 2-D temperature distribution. The simulation proved that the model and method of 2-D temperature distribution measurement could theoretically be acceptable. In the experiment, the 2-D temperature distribution of multi-chip power LEDs was measured accurately by a homemade system, thus demonstrating the feasibility of the proposed method for temperature imaging. This method is expected to provide a new solution for measuring the internal temperature distribution of opaque objects under extreme conditions. MDPI 2022-09-21 /pmc/articles/PMC9565439/ /pubmed/36234408 http://dx.doi.org/10.3390/nano12193280 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Du, Zhongzhou Hu, Bin Ye, Na Sun, Yi Zhang, Haochen Bai, Shi A Temperature Imaging Method for Multi-Chip High Power LEDs Based on the Magnetic Nanoparticle Thermometer |
title | A Temperature Imaging Method for Multi-Chip High Power LEDs Based on the Magnetic Nanoparticle Thermometer |
title_full | A Temperature Imaging Method for Multi-Chip High Power LEDs Based on the Magnetic Nanoparticle Thermometer |
title_fullStr | A Temperature Imaging Method for Multi-Chip High Power LEDs Based on the Magnetic Nanoparticle Thermometer |
title_full_unstemmed | A Temperature Imaging Method for Multi-Chip High Power LEDs Based on the Magnetic Nanoparticle Thermometer |
title_short | A Temperature Imaging Method for Multi-Chip High Power LEDs Based on the Magnetic Nanoparticle Thermometer |
title_sort | temperature imaging method for multi-chip high power leds based on the magnetic nanoparticle thermometer |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9565439/ https://www.ncbi.nlm.nih.gov/pubmed/36234408 http://dx.doi.org/10.3390/nano12193280 |
work_keys_str_mv | AT duzhongzhou atemperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT hubin atemperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT yena atemperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT sunyi atemperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT zhanghaochen atemperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT baishi atemperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT duzhongzhou temperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT hubin temperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT yena temperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT sunyi temperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT zhanghaochen temperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer AT baishi temperatureimagingmethodformultichiphighpowerledsbasedonthemagneticnanoparticlethermometer |