In vivo evaluation of histopathologic findings of vascular damage after mechanical thrombectomy with the Tromba device in a canine model of cerebral infarction

A novel stent retriever device for in vivo mechanical thrombectomy for acute cerebral infarction has been developed. In this study, we compared the thrombus removal capacity, potential complications, and extent of vessel wall damage of this novel device with those of the Solitaire FR device by perfo...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Sang-Hun, Kim, Sang Woo, Kim, Jong Min, Son, Woo Chan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9565453/
https://www.ncbi.nlm.nih.gov/pubmed/36240152
http://dx.doi.org/10.1371/journal.pone.0276108
_version_ 1784808893776396288
author Lee, Sang-Hun
Kim, Sang Woo
Kim, Jong Min
Son, Woo Chan
author_facet Lee, Sang-Hun
Kim, Sang Woo
Kim, Jong Min
Son, Woo Chan
author_sort Lee, Sang-Hun
collection PubMed
description A novel stent retriever device for in vivo mechanical thrombectomy for acute cerebral infarction has been developed. In this study, we compared the thrombus removal capacity, potential complications, and extent of vessel wall damage of this novel device with those of the Solitaire FR device by performing a histopathologic analysis using an autopsied canine model. Through this experimental evaluation, we aimed to assess the safety and efficacy of the newly developed thrombus removal device for cerebral infarction. Blood clots (autologous thrombus) were injected into 12 canines. Mechanical thrombectomy was performed in six canines using the newly developed Tromba thrombectomy device (experimental group) and in the other six canines using the Solitaire FR thrombectomy device (control group). Angiographic and histopathologic evaluations were performed 1 month after the blood vessels underwent mechanical thrombectomy. In the experimental group, the reperfusion patency was classified as “no narrowing” in five cases and “moderate narrowing (25%–50% stenosis)” in one case. In the control group, the reperfusion patency was classified as “no narrowing” in four cases, “moderate narrowing (25%–50% stenosis)” in one case, and “slight narrowing (less than 25% stenosis)” in one case. In the experimental group, intimal proliferation was observed in only two cases, endothelial loss was observed in two cases, and device-induced medial injury was observed in one case. In the control group, intimal proliferation was observed in two cases, endothelial loss was observed in one case, and thrombosis (fibrin/platelet) was observed in one case. The Tromba thrombectomy device showed no significant difference to the conventional Solitaire device in angiographic and histopathologic evaluations after thrombus removal. The stability and efficiency of the newly developed Tromba device are considered to be high and comparable to those of Solitaire.
format Online
Article
Text
id pubmed-9565453
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-95654532022-10-15 In vivo evaluation of histopathologic findings of vascular damage after mechanical thrombectomy with the Tromba device in a canine model of cerebral infarction Lee, Sang-Hun Kim, Sang Woo Kim, Jong Min Son, Woo Chan PLoS One Research Article A novel stent retriever device for in vivo mechanical thrombectomy for acute cerebral infarction has been developed. In this study, we compared the thrombus removal capacity, potential complications, and extent of vessel wall damage of this novel device with those of the Solitaire FR device by performing a histopathologic analysis using an autopsied canine model. Through this experimental evaluation, we aimed to assess the safety and efficacy of the newly developed thrombus removal device for cerebral infarction. Blood clots (autologous thrombus) were injected into 12 canines. Mechanical thrombectomy was performed in six canines using the newly developed Tromba thrombectomy device (experimental group) and in the other six canines using the Solitaire FR thrombectomy device (control group). Angiographic and histopathologic evaluations were performed 1 month after the blood vessels underwent mechanical thrombectomy. In the experimental group, the reperfusion patency was classified as “no narrowing” in five cases and “moderate narrowing (25%–50% stenosis)” in one case. In the control group, the reperfusion patency was classified as “no narrowing” in four cases, “moderate narrowing (25%–50% stenosis)” in one case, and “slight narrowing (less than 25% stenosis)” in one case. In the experimental group, intimal proliferation was observed in only two cases, endothelial loss was observed in two cases, and device-induced medial injury was observed in one case. In the control group, intimal proliferation was observed in two cases, endothelial loss was observed in one case, and thrombosis (fibrin/platelet) was observed in one case. The Tromba thrombectomy device showed no significant difference to the conventional Solitaire device in angiographic and histopathologic evaluations after thrombus removal. The stability and efficiency of the newly developed Tromba device are considered to be high and comparable to those of Solitaire. Public Library of Science 2022-10-14 /pmc/articles/PMC9565453/ /pubmed/36240152 http://dx.doi.org/10.1371/journal.pone.0276108 Text en © 2022 Lee et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Lee, Sang-Hun
Kim, Sang Woo
Kim, Jong Min
Son, Woo Chan
In vivo evaluation of histopathologic findings of vascular damage after mechanical thrombectomy with the Tromba device in a canine model of cerebral infarction
title In vivo evaluation of histopathologic findings of vascular damage after mechanical thrombectomy with the Tromba device in a canine model of cerebral infarction
title_full In vivo evaluation of histopathologic findings of vascular damage after mechanical thrombectomy with the Tromba device in a canine model of cerebral infarction
title_fullStr In vivo evaluation of histopathologic findings of vascular damage after mechanical thrombectomy with the Tromba device in a canine model of cerebral infarction
title_full_unstemmed In vivo evaluation of histopathologic findings of vascular damage after mechanical thrombectomy with the Tromba device in a canine model of cerebral infarction
title_short In vivo evaluation of histopathologic findings of vascular damage after mechanical thrombectomy with the Tromba device in a canine model of cerebral infarction
title_sort in vivo evaluation of histopathologic findings of vascular damage after mechanical thrombectomy with the tromba device in a canine model of cerebral infarction
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9565453/
https://www.ncbi.nlm.nih.gov/pubmed/36240152
http://dx.doi.org/10.1371/journal.pone.0276108
work_keys_str_mv AT leesanghun invivoevaluationofhistopathologicfindingsofvasculardamageaftermechanicalthrombectomywiththetrombadeviceinacaninemodelofcerebralinfarction
AT kimsangwoo invivoevaluationofhistopathologicfindingsofvasculardamageaftermechanicalthrombectomywiththetrombadeviceinacaninemodelofcerebralinfarction
AT kimjongmin invivoevaluationofhistopathologicfindingsofvasculardamageaftermechanicalthrombectomywiththetrombadeviceinacaninemodelofcerebralinfarction