Cargando…

Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators

The accumulation of tangential small slips at contact interfaces may occur in mechanical assemblies when subjected to cyclic loadings, and cause failure of parts. However, the slip is difficult to measure directly. In this paper, a self-powered displacement sensor based on triboelectric nanogenerato...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Wangjia, Qin, Wenjie, Ba, Mingsen, Sun, Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9565648/
https://www.ncbi.nlm.nih.gov/pubmed/36234637
http://dx.doi.org/10.3390/nano12193510
_version_ 1784808942329659392
author Zhao, Wangjia
Qin, Wenjie
Ba, Mingsen
Sun, Yu
author_facet Zhao, Wangjia
Qin, Wenjie
Ba, Mingsen
Sun, Yu
author_sort Zhao, Wangjia
collection PubMed
description The accumulation of tangential small slips at contact interfaces may occur in mechanical assemblies when subjected to cyclic loadings, and cause failure of parts. However, the slip is difficult to measure directly. In this paper, a self-powered displacement sensor based on triboelectric nanogenerator (TENG) is fabricated, which is used to measure the microslip of the specimen in the designed test bench. When the specimen slips under the cyclic tangential load with a frequency of 10 Hz, the resulted average slip displacement of the specimen under a single load cycle is 9.01 μm, which is measured by the Keithley DAQ 6510 multimeter (Tektronix, Shanghai, China). This value is close to that measured by the Keithley 6514 electrometer. In addition, adding a [Formula: see text] thin film with a thickness of 100 nm between the Kapton triboelectric layer and the Cu electrode, the output voltage of the sensor is increased by 51.5%. Thus, the sensitivity of the self-powered sensor is improved effectively.
format Online
Article
Text
id pubmed-9565648
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95656482022-10-15 Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators Zhao, Wangjia Qin, Wenjie Ba, Mingsen Sun, Yu Nanomaterials (Basel) Article The accumulation of tangential small slips at contact interfaces may occur in mechanical assemblies when subjected to cyclic loadings, and cause failure of parts. However, the slip is difficult to measure directly. In this paper, a self-powered displacement sensor based on triboelectric nanogenerator (TENG) is fabricated, which is used to measure the microslip of the specimen in the designed test bench. When the specimen slips under the cyclic tangential load with a frequency of 10 Hz, the resulted average slip displacement of the specimen under a single load cycle is 9.01 μm, which is measured by the Keithley DAQ 6510 multimeter (Tektronix, Shanghai, China). This value is close to that measured by the Keithley 6514 electrometer. In addition, adding a [Formula: see text] thin film with a thickness of 100 nm between the Kapton triboelectric layer and the Cu electrode, the output voltage of the sensor is increased by 51.5%. Thus, the sensitivity of the self-powered sensor is improved effectively. MDPI 2022-10-07 /pmc/articles/PMC9565648/ /pubmed/36234637 http://dx.doi.org/10.3390/nano12193510 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhao, Wangjia
Qin, Wenjie
Ba, Mingsen
Sun, Yu
Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators
title Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators
title_full Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators
title_fullStr Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators
title_full_unstemmed Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators
title_short Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators
title_sort measurement of slips at contact interfaces using a self-powered sensor based on triboelectric nanogenerators
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9565648/
https://www.ncbi.nlm.nih.gov/pubmed/36234637
http://dx.doi.org/10.3390/nano12193510
work_keys_str_mv AT zhaowangjia measurementofslipsatcontactinterfacesusingaselfpoweredsensorbasedontriboelectricnanogenerators
AT qinwenjie measurementofslipsatcontactinterfacesusingaselfpoweredsensorbasedontriboelectricnanogenerators
AT bamingsen measurementofslipsatcontactinterfacesusingaselfpoweredsensorbasedontriboelectricnanogenerators
AT sunyu measurementofslipsatcontactinterfacesusingaselfpoweredsensorbasedontriboelectricnanogenerators