Cargando…
Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators
The accumulation of tangential small slips at contact interfaces may occur in mechanical assemblies when subjected to cyclic loadings, and cause failure of parts. However, the slip is difficult to measure directly. In this paper, a self-powered displacement sensor based on triboelectric nanogenerato...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9565648/ https://www.ncbi.nlm.nih.gov/pubmed/36234637 http://dx.doi.org/10.3390/nano12193510 |
_version_ | 1784808942329659392 |
---|---|
author | Zhao, Wangjia Qin, Wenjie Ba, Mingsen Sun, Yu |
author_facet | Zhao, Wangjia Qin, Wenjie Ba, Mingsen Sun, Yu |
author_sort | Zhao, Wangjia |
collection | PubMed |
description | The accumulation of tangential small slips at contact interfaces may occur in mechanical assemblies when subjected to cyclic loadings, and cause failure of parts. However, the slip is difficult to measure directly. In this paper, a self-powered displacement sensor based on triboelectric nanogenerator (TENG) is fabricated, which is used to measure the microslip of the specimen in the designed test bench. When the specimen slips under the cyclic tangential load with a frequency of 10 Hz, the resulted average slip displacement of the specimen under a single load cycle is 9.01 μm, which is measured by the Keithley DAQ 6510 multimeter (Tektronix, Shanghai, China). This value is close to that measured by the Keithley 6514 electrometer. In addition, adding a [Formula: see text] thin film with a thickness of 100 nm between the Kapton triboelectric layer and the Cu electrode, the output voltage of the sensor is increased by 51.5%. Thus, the sensitivity of the self-powered sensor is improved effectively. |
format | Online Article Text |
id | pubmed-9565648 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95656482022-10-15 Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators Zhao, Wangjia Qin, Wenjie Ba, Mingsen Sun, Yu Nanomaterials (Basel) Article The accumulation of tangential small slips at contact interfaces may occur in mechanical assemblies when subjected to cyclic loadings, and cause failure of parts. However, the slip is difficult to measure directly. In this paper, a self-powered displacement sensor based on triboelectric nanogenerator (TENG) is fabricated, which is used to measure the microslip of the specimen in the designed test bench. When the specimen slips under the cyclic tangential load with a frequency of 10 Hz, the resulted average slip displacement of the specimen under a single load cycle is 9.01 μm, which is measured by the Keithley DAQ 6510 multimeter (Tektronix, Shanghai, China). This value is close to that measured by the Keithley 6514 electrometer. In addition, adding a [Formula: see text] thin film with a thickness of 100 nm between the Kapton triboelectric layer and the Cu electrode, the output voltage of the sensor is increased by 51.5%. Thus, the sensitivity of the self-powered sensor is improved effectively. MDPI 2022-10-07 /pmc/articles/PMC9565648/ /pubmed/36234637 http://dx.doi.org/10.3390/nano12193510 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhao, Wangjia Qin, Wenjie Ba, Mingsen Sun, Yu Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators |
title | Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators |
title_full | Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators |
title_fullStr | Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators |
title_full_unstemmed | Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators |
title_short | Measurement of Slips at Contact Interfaces Using a Self-Powered Sensor Based on Triboelectric Nanogenerators |
title_sort | measurement of slips at contact interfaces using a self-powered sensor based on triboelectric nanogenerators |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9565648/ https://www.ncbi.nlm.nih.gov/pubmed/36234637 http://dx.doi.org/10.3390/nano12193510 |
work_keys_str_mv | AT zhaowangjia measurementofslipsatcontactinterfacesusingaselfpoweredsensorbasedontriboelectricnanogenerators AT qinwenjie measurementofslipsatcontactinterfacesusingaselfpoweredsensorbasedontriboelectricnanogenerators AT bamingsen measurementofslipsatcontactinterfacesusingaselfpoweredsensorbasedontriboelectricnanogenerators AT sunyu measurementofslipsatcontactinterfacesusingaselfpoweredsensorbasedontriboelectricnanogenerators |