A hydrophobic layer prepared by cyclic grafting of polydimethylsiloxane on magnesium: improved corrosion resistance and biocompatibility
Magnesium and its alloys have been widely studied as absorbable coronary stent materials. However, the rapid corrosion rate in the intravascular environment inhibits the application of magnesium-based stents. In order to endow magnesium-based stent with appropriate degradation rate and biocompatibil...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9566967/ https://www.ncbi.nlm.nih.gov/pubmed/36267153 http://dx.doi.org/10.1093/rb/rbac068 |
_version_ | 1784809283472326656 |
---|---|
author | Shen, Xiaolong Zhang, Hao Li, Xin Li, Peichuang Zhao, Yuancong Wang, Yunbing Wang, Jin |
author_facet | Shen, Xiaolong Zhang, Hao Li, Xin Li, Peichuang Zhao, Yuancong Wang, Yunbing Wang, Jin |
author_sort | Shen, Xiaolong |
collection | PubMed |
description | Magnesium and its alloys have been widely studied as absorbable coronary stent materials. However, the rapid corrosion rate in the intravascular environment inhibits the application of magnesium-based stents. In order to endow magnesium-based stent with appropriate degradation rate and biocompatibility, a hydrophobic layer was constructed by in situ cyclic grafting 4,4′-diphenylmethane diisocyanate and aminopropyl-terminated polydimethylsiloxane on pure magnesium. SEM-EDS, X-ray photoelectron spectroscopy and water contact angle were detected to analyze the chemical composition of the layer. The amino groups were confirmed to be introduced on the surface which provide a platform for subsequent modification. The contact angle value of the modified surface is 132.1°, indicating a hydrophilic surface. The electrochemical measurements and immersion tests demonstrated that the hydrophobic layer significantly improved the anti-corrosion ability of the substrate. Besides, the biocompatibility of the hydrophobic surface was examined by platelet adhesion, cytocompatibility in vitro and subcutaneous implantation in vivo. Immunological and histological results indicated that the hydrophobic layer had excellent biocompatibility. Therefore, the presented study might be a promising method for the surface modification of biomedical magnesium-based stent. |
format | Online Article Text |
id | pubmed-9566967 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-95669672022-10-19 A hydrophobic layer prepared by cyclic grafting of polydimethylsiloxane on magnesium: improved corrosion resistance and biocompatibility Shen, Xiaolong Zhang, Hao Li, Xin Li, Peichuang Zhao, Yuancong Wang, Yunbing Wang, Jin Regen Biomater Research Article Magnesium and its alloys have been widely studied as absorbable coronary stent materials. However, the rapid corrosion rate in the intravascular environment inhibits the application of magnesium-based stents. In order to endow magnesium-based stent with appropriate degradation rate and biocompatibility, a hydrophobic layer was constructed by in situ cyclic grafting 4,4′-diphenylmethane diisocyanate and aminopropyl-terminated polydimethylsiloxane on pure magnesium. SEM-EDS, X-ray photoelectron spectroscopy and water contact angle were detected to analyze the chemical composition of the layer. The amino groups were confirmed to be introduced on the surface which provide a platform for subsequent modification. The contact angle value of the modified surface is 132.1°, indicating a hydrophilic surface. The electrochemical measurements and immersion tests demonstrated that the hydrophobic layer significantly improved the anti-corrosion ability of the substrate. Besides, the biocompatibility of the hydrophobic surface was examined by platelet adhesion, cytocompatibility in vitro and subcutaneous implantation in vivo. Immunological and histological results indicated that the hydrophobic layer had excellent biocompatibility. Therefore, the presented study might be a promising method for the surface modification of biomedical magnesium-based stent. Oxford University Press 2022-09-29 /pmc/articles/PMC9566967/ /pubmed/36267153 http://dx.doi.org/10.1093/rb/rbac068 Text en © The Author(s) 2022. Published by Oxford University Press. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Shen, Xiaolong Zhang, Hao Li, Xin Li, Peichuang Zhao, Yuancong Wang, Yunbing Wang, Jin A hydrophobic layer prepared by cyclic grafting of polydimethylsiloxane on magnesium: improved corrosion resistance and biocompatibility |
title | A hydrophobic layer prepared by cyclic grafting of polydimethylsiloxane on magnesium: improved corrosion resistance and biocompatibility |
title_full | A hydrophobic layer prepared by cyclic grafting of polydimethylsiloxane on magnesium: improved corrosion resistance and biocompatibility |
title_fullStr | A hydrophobic layer prepared by cyclic grafting of polydimethylsiloxane on magnesium: improved corrosion resistance and biocompatibility |
title_full_unstemmed | A hydrophobic layer prepared by cyclic grafting of polydimethylsiloxane on magnesium: improved corrosion resistance and biocompatibility |
title_short | A hydrophobic layer prepared by cyclic grafting of polydimethylsiloxane on magnesium: improved corrosion resistance and biocompatibility |
title_sort | hydrophobic layer prepared by cyclic grafting of polydimethylsiloxane on magnesium: improved corrosion resistance and biocompatibility |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9566967/ https://www.ncbi.nlm.nih.gov/pubmed/36267153 http://dx.doi.org/10.1093/rb/rbac068 |
work_keys_str_mv | AT shenxiaolong ahydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT zhanghao ahydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT lixin ahydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT lipeichuang ahydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT zhaoyuancong ahydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT wangyunbing ahydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT wangjin ahydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT shenxiaolong hydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT zhanghao hydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT lixin hydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT lipeichuang hydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT zhaoyuancong hydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT wangyunbing hydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility AT wangjin hydrophobiclayerpreparedbycyclicgraftingofpolydimethylsiloxaneonmagnesiumimprovedcorrosionresistanceandbiocompatibility |