Cargando…

A simple way to deal with an inadvertently cut suture while inserting the screw in the tibial tunnel during ACL reconstruction

INTRODUCTION: There are many complications that can occur during or after ACL reconstruction, including a suture inadvertently cut by the screw threads while inserting the interference screw in the tibial tunnel. No fixes for this small but annoying problem have been proposed to date in the literatu...

Descripción completa

Detalles Bibliográficos
Autores principales: Chuaychoosakoon, Chaiwat, Maliwankul, Korakot, Parinyakhup, Wachiraphan, Boonriong, Tanarat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9568767/
https://www.ncbi.nlm.nih.gov/pubmed/36183590
http://dx.doi.org/10.1016/j.ijscr.2022.107687
_version_ 1784809712055746560
author Chuaychoosakoon, Chaiwat
Maliwankul, Korakot
Parinyakhup, Wachiraphan
Boonriong, Tanarat
author_facet Chuaychoosakoon, Chaiwat
Maliwankul, Korakot
Parinyakhup, Wachiraphan
Boonriong, Tanarat
author_sort Chuaychoosakoon, Chaiwat
collection PubMed
description INTRODUCTION: There are many complications that can occur during or after ACL reconstruction, including a suture inadvertently cut by the screw threads while inserting the interference screw in the tibial tunnel. No fixes for this small but annoying problem have been proposed to date in the literature, and herein we propose a simple way to deal with this situation by bringing the tibial side of the ACL graft through the anterolateral portal and re-suturing with a stronger suture material. CASE PRESENTATION: A 48-year-old Thai female was undergoing an ACL reconstruction with a hamstring graft following a standard technique when the holding suture and distal part of the ACL graft were accidentally cut by the screw. Rather than redoing the graft from the beginning, we did a workaround by bringing the tibial end of the graft through the AL portal and re-suturing. DISCUSSION: In ACL graft fixation, when inserting the interference screw into the tibial tunnel there is a risk of cutting the holding suture with the screw. When this happened in our situation, we decided to attempt to redo the suture by first taking the graft out through the AL portal and then re-suturing with a stronger suture material. CONCLUSION: If inadvertently cutting the holding suture while inserting the screw in the tibial tunnel during ACL reconstruction occurs, the surgeon can use the simple solution we applied in this case to solve this problem or to avoid having to redo the entire procedure.
format Online
Article
Text
id pubmed-9568767
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-95687672022-10-16 A simple way to deal with an inadvertently cut suture while inserting the screw in the tibial tunnel during ACL reconstruction Chuaychoosakoon, Chaiwat Maliwankul, Korakot Parinyakhup, Wachiraphan Boonriong, Tanarat Int J Surg Case Rep Case Report INTRODUCTION: There are many complications that can occur during or after ACL reconstruction, including a suture inadvertently cut by the screw threads while inserting the interference screw in the tibial tunnel. No fixes for this small but annoying problem have been proposed to date in the literature, and herein we propose a simple way to deal with this situation by bringing the tibial side of the ACL graft through the anterolateral portal and re-suturing with a stronger suture material. CASE PRESENTATION: A 48-year-old Thai female was undergoing an ACL reconstruction with a hamstring graft following a standard technique when the holding suture and distal part of the ACL graft were accidentally cut by the screw. Rather than redoing the graft from the beginning, we did a workaround by bringing the tibial end of the graft through the AL portal and re-suturing. DISCUSSION: In ACL graft fixation, when inserting the interference screw into the tibial tunnel there is a risk of cutting the holding suture with the screw. When this happened in our situation, we decided to attempt to redo the suture by first taking the graft out through the AL portal and then re-suturing with a stronger suture material. CONCLUSION: If inadvertently cutting the holding suture while inserting the screw in the tibial tunnel during ACL reconstruction occurs, the surgeon can use the simple solution we applied in this case to solve this problem or to avoid having to redo the entire procedure. Elsevier 2022-09-19 /pmc/articles/PMC9568767/ /pubmed/36183590 http://dx.doi.org/10.1016/j.ijscr.2022.107687 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Chuaychoosakoon, Chaiwat
Maliwankul, Korakot
Parinyakhup, Wachiraphan
Boonriong, Tanarat
A simple way to deal with an inadvertently cut suture while inserting the screw in the tibial tunnel during ACL reconstruction
title A simple way to deal with an inadvertently cut suture while inserting the screw in the tibial tunnel during ACL reconstruction
title_full A simple way to deal with an inadvertently cut suture while inserting the screw in the tibial tunnel during ACL reconstruction
title_fullStr A simple way to deal with an inadvertently cut suture while inserting the screw in the tibial tunnel during ACL reconstruction
title_full_unstemmed A simple way to deal with an inadvertently cut suture while inserting the screw in the tibial tunnel during ACL reconstruction
title_short A simple way to deal with an inadvertently cut suture while inserting the screw in the tibial tunnel during ACL reconstruction
title_sort simple way to deal with an inadvertently cut suture while inserting the screw in the tibial tunnel during acl reconstruction
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9568767/
https://www.ncbi.nlm.nih.gov/pubmed/36183590
http://dx.doi.org/10.1016/j.ijscr.2022.107687
work_keys_str_mv AT chuaychoosakoonchaiwat asimplewaytodealwithaninadvertentlycutsuturewhileinsertingthescrewinthetibialtunnelduringaclreconstruction
AT maliwankulkorakot asimplewaytodealwithaninadvertentlycutsuturewhileinsertingthescrewinthetibialtunnelduringaclreconstruction
AT parinyakhupwachiraphan asimplewaytodealwithaninadvertentlycutsuturewhileinsertingthescrewinthetibialtunnelduringaclreconstruction
AT boonriongtanarat asimplewaytodealwithaninadvertentlycutsuturewhileinsertingthescrewinthetibialtunnelduringaclreconstruction
AT chuaychoosakoonchaiwat simplewaytodealwithaninadvertentlycutsuturewhileinsertingthescrewinthetibialtunnelduringaclreconstruction
AT maliwankulkorakot simplewaytodealwithaninadvertentlycutsuturewhileinsertingthescrewinthetibialtunnelduringaclreconstruction
AT parinyakhupwachiraphan simplewaytodealwithaninadvertentlycutsuturewhileinsertingthescrewinthetibialtunnelduringaclreconstruction
AT boonriongtanarat simplewaytodealwithaninadvertentlycutsuturewhileinsertingthescrewinthetibialtunnelduringaclreconstruction