Cargando…

Pseudo-aortic dissection after sudden cardiac death in coronary angiography a case report: Pearls and pitfalls in false aortic dissection artifacts

INTRODUCTION AND IMPORTANCE: Various artifacts mimicked aortic dissection, such as streak artifacts generated by high-attenuation material, high-contrast interfaces, cardiac motion, periaortic structures, aortic wall motion, and normal aortic sinuses, have been described in the literature. Most arti...

Descripción completa

Detalles Bibliográficos
Autores principales: García-Escobar, Artemio, Vera-Vera, Silvio, Jurado-Román, Alfonso, Jiménez-Valero, Santiago, Galeote, Guillermo, Moreno, Raúl
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9568788/
https://www.ncbi.nlm.nih.gov/pubmed/36116308
http://dx.doi.org/10.1016/j.ijscr.2022.107659
_version_ 1784809716946305024
author García-Escobar, Artemio
Vera-Vera, Silvio
Jurado-Román, Alfonso
Jiménez-Valero, Santiago
Galeote, Guillermo
Moreno, Raúl
author_facet García-Escobar, Artemio
Vera-Vera, Silvio
Jurado-Román, Alfonso
Jiménez-Valero, Santiago
Galeote, Guillermo
Moreno, Raúl
author_sort García-Escobar, Artemio
collection PubMed
description INTRODUCTION AND IMPORTANCE: Various artifacts mimicked aortic dissection, such as streak artifacts generated by high-attenuation material, high-contrast interfaces, cardiac motion, periaortic structures, aortic wall motion, and normal aortic sinuses, have been described in the literature. Most artifacts that simulate ascending aortic dissection occur frequently on conventional CT. Their position is predictable and is related to systolic aortic motion. However, so far, to the best of our knowledge, this is the first pseudo-aortic dissection reported during coronary angiography in cardiac arrest. CASE PRESENTATION: We report a case of a middle-aged man transferred to our hospital after an out-of-hospital cardiac arrest. The coronary angiography revealed non-obstructive coronary arteries and an image of probable aortic dissection was observed. Given the persistent asystole despite a prolonged advance cardiopulmonary resuscitation and the possibility of aortic dissection, a prompt in-room heart team discussion was performed. It was decided to stop and withdraw potentially life-sustaining treatment due to futility. The necropsy study revealed the aorta with some mild atherosclerotic plaques but without either aneurysm or thrombosis. The coronary arteries were reported as with patency, but in the proximal left anterior descending artery (LAD), the intima layer presented a thickness that decreased 50 % of the luminal area without signs of complicated acute plaques. CLINICAL DISCUSSION: In this case, the systolic aortic motion theory cannot explain the false-aortic dissection image in the coronary angiography because the patient was under cardiac arrest. Studies with arterial and venous pressures devices recording in cardiac arrest, demonstrated an abnormal hemodynamic flow, suggesting that the hemodynamic flow might be backward during cardiopulmonary resuscitation Therefore, in the setting of this abnormal hemodynamic flow, the injection of contrast may have an abnormal distribution and flow in the aorta creating an image of pseudo-aortic dissection. CONCLUSION: Although the exact mechanism of this false-positive aortic dissection in cardiac arrest remains unknown, operators should be aware of this entity during coronary angiography in the setting of cardiac arrest with mechanical chest compressions to avoid diagnostic errors in clinical practice.
format Online
Article
Text
id pubmed-9568788
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-95687882022-10-16 Pseudo-aortic dissection after sudden cardiac death in coronary angiography a case report: Pearls and pitfalls in false aortic dissection artifacts García-Escobar, Artemio Vera-Vera, Silvio Jurado-Román, Alfonso Jiménez-Valero, Santiago Galeote, Guillermo Moreno, Raúl Int J Surg Case Rep Case Report INTRODUCTION AND IMPORTANCE: Various artifacts mimicked aortic dissection, such as streak artifacts generated by high-attenuation material, high-contrast interfaces, cardiac motion, periaortic structures, aortic wall motion, and normal aortic sinuses, have been described in the literature. Most artifacts that simulate ascending aortic dissection occur frequently on conventional CT. Their position is predictable and is related to systolic aortic motion. However, so far, to the best of our knowledge, this is the first pseudo-aortic dissection reported during coronary angiography in cardiac arrest. CASE PRESENTATION: We report a case of a middle-aged man transferred to our hospital after an out-of-hospital cardiac arrest. The coronary angiography revealed non-obstructive coronary arteries and an image of probable aortic dissection was observed. Given the persistent asystole despite a prolonged advance cardiopulmonary resuscitation and the possibility of aortic dissection, a prompt in-room heart team discussion was performed. It was decided to stop and withdraw potentially life-sustaining treatment due to futility. The necropsy study revealed the aorta with some mild atherosclerotic plaques but without either aneurysm or thrombosis. The coronary arteries were reported as with patency, but in the proximal left anterior descending artery (LAD), the intima layer presented a thickness that decreased 50 % of the luminal area without signs of complicated acute plaques. CLINICAL DISCUSSION: In this case, the systolic aortic motion theory cannot explain the false-aortic dissection image in the coronary angiography because the patient was under cardiac arrest. Studies with arterial and venous pressures devices recording in cardiac arrest, demonstrated an abnormal hemodynamic flow, suggesting that the hemodynamic flow might be backward during cardiopulmonary resuscitation Therefore, in the setting of this abnormal hemodynamic flow, the injection of contrast may have an abnormal distribution and flow in the aorta creating an image of pseudo-aortic dissection. CONCLUSION: Although the exact mechanism of this false-positive aortic dissection in cardiac arrest remains unknown, operators should be aware of this entity during coronary angiography in the setting of cardiac arrest with mechanical chest compressions to avoid diagnostic errors in clinical practice. Elsevier 2022-09-14 /pmc/articles/PMC9568788/ /pubmed/36116308 http://dx.doi.org/10.1016/j.ijscr.2022.107659 Text en © 2022 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Case Report
García-Escobar, Artemio
Vera-Vera, Silvio
Jurado-Román, Alfonso
Jiménez-Valero, Santiago
Galeote, Guillermo
Moreno, Raúl
Pseudo-aortic dissection after sudden cardiac death in coronary angiography a case report: Pearls and pitfalls in false aortic dissection artifacts
title Pseudo-aortic dissection after sudden cardiac death in coronary angiography a case report: Pearls and pitfalls in false aortic dissection artifacts
title_full Pseudo-aortic dissection after sudden cardiac death in coronary angiography a case report: Pearls and pitfalls in false aortic dissection artifacts
title_fullStr Pseudo-aortic dissection after sudden cardiac death in coronary angiography a case report: Pearls and pitfalls in false aortic dissection artifacts
title_full_unstemmed Pseudo-aortic dissection after sudden cardiac death in coronary angiography a case report: Pearls and pitfalls in false aortic dissection artifacts
title_short Pseudo-aortic dissection after sudden cardiac death in coronary angiography a case report: Pearls and pitfalls in false aortic dissection artifacts
title_sort pseudo-aortic dissection after sudden cardiac death in coronary angiography a case report: pearls and pitfalls in false aortic dissection artifacts
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9568788/
https://www.ncbi.nlm.nih.gov/pubmed/36116308
http://dx.doi.org/10.1016/j.ijscr.2022.107659
work_keys_str_mv AT garciaescobarartemio pseudoaorticdissectionaftersuddencardiacdeathincoronaryangiographyacasereportpearlsandpitfallsinfalseaorticdissectionartifacts
AT veraverasilvio pseudoaorticdissectionaftersuddencardiacdeathincoronaryangiographyacasereportpearlsandpitfallsinfalseaorticdissectionartifacts
AT juradoromanalfonso pseudoaorticdissectionaftersuddencardiacdeathincoronaryangiographyacasereportpearlsandpitfallsinfalseaorticdissectionartifacts
AT jimenezvalerosantiago pseudoaorticdissectionaftersuddencardiacdeathincoronaryangiographyacasereportpearlsandpitfallsinfalseaorticdissectionartifacts
AT galeoteguillermo pseudoaorticdissectionaftersuddencardiacdeathincoronaryangiographyacasereportpearlsandpitfallsinfalseaorticdissectionartifacts
AT morenoraul pseudoaorticdissectionaftersuddencardiacdeathincoronaryangiographyacasereportpearlsandpitfallsinfalseaorticdissectionartifacts