Cargando…

Comparison between stone and digital cast measurements in mixed dentition: Validity, reliability, reproducibility, and objectivity

PURPOSE: To assess the validity, reliability, reproducibility, and objectivity of measurements on stone casts of patients with mixed dentitions compared to measurements on three-dimensional (3D) digital models derived from surface scans of the stone casts. METHODS: Pairs of stone casts of 30 young p...

Descripción completa

Detalles Bibliográficos
Autores principales: Schieffer, Lisa, Latzko, Lukas, Ulmer, Hanno, Schenz-Spisic, Natalie, Lepperdinger, Ulrike, Paulus, Magdalena, Crismani, Adriano G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Medizin 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9569293/
https://www.ncbi.nlm.nih.gov/pubmed/35238945
http://dx.doi.org/10.1007/s00056-022-00376-9
_version_ 1784809823352651776
author Schieffer, Lisa
Latzko, Lukas
Ulmer, Hanno
Schenz-Spisic, Natalie
Lepperdinger, Ulrike
Paulus, Magdalena
Crismani, Adriano G.
author_facet Schieffer, Lisa
Latzko, Lukas
Ulmer, Hanno
Schenz-Spisic, Natalie
Lepperdinger, Ulrike
Paulus, Magdalena
Crismani, Adriano G.
author_sort Schieffer, Lisa
collection PubMed
description PURPOSE: To assess the validity, reliability, reproducibility, and objectivity of measurements on stone casts of patients with mixed dentitions compared to measurements on three-dimensional (3D) digital models derived from surface scans of the stone casts. METHODS: Pairs of stone casts of 30 young patients in their mixed dentition stage were included and processed into 3D digital models using an intraoral scanner (iTero Element 2; Align Technology, San Jose, CA, USA). Then an experienced and an inexperienced examiner independently performed measurements of five defined parameters, each in triplicate, both on the digital models with analysis software (OnyxCeph3™; Image Instruments, Chemnitz, Germany) and on the original casts with a vernier calliper. Paired t-tests were used for validity and interexaminer objectivity, Pearson correlation coefficients for intermethod reliability, and intraclass correlation coefficients (ICCs) for reproducibility testing. RESULTS: Significant (p < 0.05) intermethod differences were identified for four parameters, but only the differences for overbite and intermolar distance exceeded the threshold of clinical relevance (≥ 0.5 mm). Intermethod reliability was high and method error invariably lower for the digital measurements and for the experienced examiner. Both examiners achieved ICCs > 0.907 with both methods. Interexaminer variation involved significant differences for all parameters but one (intermolar distance) on the stone casts and for three parameters on the digital models. CONCLUSION: Measurements performed on digital models of mixed dentitions can yield clinically acceptable outcomes with OnyxCeph3™ software. Both the digital and the analogue measurements were highly reproducible and reliable. Objectivity of the measurements could not be confirmed, as operator experience did make a difference.
format Online
Article
Text
id pubmed-9569293
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Medizin
record_format MEDLINE/PubMed
spelling pubmed-95692932022-10-17 Comparison between stone and digital cast measurements in mixed dentition: Validity, reliability, reproducibility, and objectivity Schieffer, Lisa Latzko, Lukas Ulmer, Hanno Schenz-Spisic, Natalie Lepperdinger, Ulrike Paulus, Magdalena Crismani, Adriano G. J Orofac Orthop Original Article PURPOSE: To assess the validity, reliability, reproducibility, and objectivity of measurements on stone casts of patients with mixed dentitions compared to measurements on three-dimensional (3D) digital models derived from surface scans of the stone casts. METHODS: Pairs of stone casts of 30 young patients in their mixed dentition stage were included and processed into 3D digital models using an intraoral scanner (iTero Element 2; Align Technology, San Jose, CA, USA). Then an experienced and an inexperienced examiner independently performed measurements of five defined parameters, each in triplicate, both on the digital models with analysis software (OnyxCeph3™; Image Instruments, Chemnitz, Germany) and on the original casts with a vernier calliper. Paired t-tests were used for validity and interexaminer objectivity, Pearson correlation coefficients for intermethod reliability, and intraclass correlation coefficients (ICCs) for reproducibility testing. RESULTS: Significant (p < 0.05) intermethod differences were identified for four parameters, but only the differences for overbite and intermolar distance exceeded the threshold of clinical relevance (≥ 0.5 mm). Intermethod reliability was high and method error invariably lower for the digital measurements and for the experienced examiner. Both examiners achieved ICCs > 0.907 with both methods. Interexaminer variation involved significant differences for all parameters but one (intermolar distance) on the stone casts and for three parameters on the digital models. CONCLUSION: Measurements performed on digital models of mixed dentitions can yield clinically acceptable outcomes with OnyxCeph3™ software. Both the digital and the analogue measurements were highly reproducible and reliable. Objectivity of the measurements could not be confirmed, as operator experience did make a difference. Springer Medizin 2022-03-03 2022 /pmc/articles/PMC9569293/ /pubmed/35238945 http://dx.doi.org/10.1007/s00056-022-00376-9 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Schieffer, Lisa
Latzko, Lukas
Ulmer, Hanno
Schenz-Spisic, Natalie
Lepperdinger, Ulrike
Paulus, Magdalena
Crismani, Adriano G.
Comparison between stone and digital cast measurements in mixed dentition: Validity, reliability, reproducibility, and objectivity
title Comparison between stone and digital cast measurements in mixed dentition: Validity, reliability, reproducibility, and objectivity
title_full Comparison between stone and digital cast measurements in mixed dentition: Validity, reliability, reproducibility, and objectivity
title_fullStr Comparison between stone and digital cast measurements in mixed dentition: Validity, reliability, reproducibility, and objectivity
title_full_unstemmed Comparison between stone and digital cast measurements in mixed dentition: Validity, reliability, reproducibility, and objectivity
title_short Comparison between stone and digital cast measurements in mixed dentition: Validity, reliability, reproducibility, and objectivity
title_sort comparison between stone and digital cast measurements in mixed dentition: validity, reliability, reproducibility, and objectivity
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9569293/
https://www.ncbi.nlm.nih.gov/pubmed/35238945
http://dx.doi.org/10.1007/s00056-022-00376-9
work_keys_str_mv AT schiefferlisa comparisonbetweenstoneanddigitalcastmeasurementsinmixeddentitionvalidityreliabilityreproducibilityandobjectivity
AT latzkolukas comparisonbetweenstoneanddigitalcastmeasurementsinmixeddentitionvalidityreliabilityreproducibilityandobjectivity
AT ulmerhanno comparisonbetweenstoneanddigitalcastmeasurementsinmixeddentitionvalidityreliabilityreproducibilityandobjectivity
AT schenzspisicnatalie comparisonbetweenstoneanddigitalcastmeasurementsinmixeddentitionvalidityreliabilityreproducibilityandobjectivity
AT lepperdingerulrike comparisonbetweenstoneanddigitalcastmeasurementsinmixeddentitionvalidityreliabilityreproducibilityandobjectivity
AT paulusmagdalena comparisonbetweenstoneanddigitalcastmeasurementsinmixeddentitionvalidityreliabilityreproducibilityandobjectivity
AT crismaniadrianog comparisonbetweenstoneanddigitalcastmeasurementsinmixeddentitionvalidityreliabilityreproducibilityandobjectivity