Cargando…

Calibration of BRDF Based on the Field Goniometer System Using a UAV Multispectral Camera

The bidirectional reflectance distribution function (BRDF) is important for estimating the physical properties of a surface in remote sensing. In the laboratory, the BRDF can be estimated quickly and accurately using a goniometer, but it is very difficult to operate in the field. The purpose of this...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Minji, Jin, Cheonggil, Lee, Sejin, Kim, Kyoung-Min, Lim, Joongbin, Choi, Chuluong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9570825/
https://www.ncbi.nlm.nih.gov/pubmed/36236578
http://dx.doi.org/10.3390/s22197476
_version_ 1784810207153487872
author Kim, Minji
Jin, Cheonggil
Lee, Sejin
Kim, Kyoung-Min
Lim, Joongbin
Choi, Chuluong
author_facet Kim, Minji
Jin, Cheonggil
Lee, Sejin
Kim, Kyoung-Min
Lim, Joongbin
Choi, Chuluong
author_sort Kim, Minji
collection PubMed
description The bidirectional reflectance distribution function (BRDF) is important for estimating the physical properties of a surface in remote sensing. In the laboratory, the BRDF can be estimated quickly and accurately using a goniometer, but it is very difficult to operate in the field. The purpose of this study was to evaluate whether estimating the BRDF with reasonable accuracy using an unmanned aerial vehicle (UAV) with a multispectral camera is possible in the field. Hemispherical reflectance was created from images taken using an UAV multispectral camera. The ground targets were four calibrated reference tarps (CRTs) of different reflectance, and the UAV was operated five times. Down-welling irradiance for reflectance calculation was measured in two ways: a sunlight sensor was mounted on a UAV, and a spectroradiometer with a remote cosine receptor (RCR) was installed on the ground. The BRDF was assessed through the anisotropy factor (ANIF) of the CRT reflectance derived from the collected data. As a result, the irradiance data for the reflectance calculation were more effective from the spectroradiometer with RCR on the ground than from the sunlight sensor mounted on an UAV. Furthermore, the high reflectance CRTs, ANIF, and BRDF had similar results. Therefore, when analyzing the BRDF, the effectiveness can be guaranteed when the reflectance of the target is over 21~46%, because a low reflectance tendency differs due to the adjacency effect. In addition, weather affects irradiance, so it is more effective to conduct fieldwork in clear weather.
format Online
Article
Text
id pubmed-9570825
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95708252022-10-17 Calibration of BRDF Based on the Field Goniometer System Using a UAV Multispectral Camera Kim, Minji Jin, Cheonggil Lee, Sejin Kim, Kyoung-Min Lim, Joongbin Choi, Chuluong Sensors (Basel) Article The bidirectional reflectance distribution function (BRDF) is important for estimating the physical properties of a surface in remote sensing. In the laboratory, the BRDF can be estimated quickly and accurately using a goniometer, but it is very difficult to operate in the field. The purpose of this study was to evaluate whether estimating the BRDF with reasonable accuracy using an unmanned aerial vehicle (UAV) with a multispectral camera is possible in the field. Hemispherical reflectance was created from images taken using an UAV multispectral camera. The ground targets were four calibrated reference tarps (CRTs) of different reflectance, and the UAV was operated five times. Down-welling irradiance for reflectance calculation was measured in two ways: a sunlight sensor was mounted on a UAV, and a spectroradiometer with a remote cosine receptor (RCR) was installed on the ground. The BRDF was assessed through the anisotropy factor (ANIF) of the CRT reflectance derived from the collected data. As a result, the irradiance data for the reflectance calculation were more effective from the spectroradiometer with RCR on the ground than from the sunlight sensor mounted on an UAV. Furthermore, the high reflectance CRTs, ANIF, and BRDF had similar results. Therefore, when analyzing the BRDF, the effectiveness can be guaranteed when the reflectance of the target is over 21~46%, because a low reflectance tendency differs due to the adjacency effect. In addition, weather affects irradiance, so it is more effective to conduct fieldwork in clear weather. MDPI 2022-10-02 /pmc/articles/PMC9570825/ /pubmed/36236578 http://dx.doi.org/10.3390/s22197476 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kim, Minji
Jin, Cheonggil
Lee, Sejin
Kim, Kyoung-Min
Lim, Joongbin
Choi, Chuluong
Calibration of BRDF Based on the Field Goniometer System Using a UAV Multispectral Camera
title Calibration of BRDF Based on the Field Goniometer System Using a UAV Multispectral Camera
title_full Calibration of BRDF Based on the Field Goniometer System Using a UAV Multispectral Camera
title_fullStr Calibration of BRDF Based on the Field Goniometer System Using a UAV Multispectral Camera
title_full_unstemmed Calibration of BRDF Based on the Field Goniometer System Using a UAV Multispectral Camera
title_short Calibration of BRDF Based on the Field Goniometer System Using a UAV Multispectral Camera
title_sort calibration of brdf based on the field goniometer system using a uav multispectral camera
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9570825/
https://www.ncbi.nlm.nih.gov/pubmed/36236578
http://dx.doi.org/10.3390/s22197476
work_keys_str_mv AT kimminji calibrationofbrdfbasedonthefieldgoniometersystemusingauavmultispectralcamera
AT jincheonggil calibrationofbrdfbasedonthefieldgoniometersystemusingauavmultispectralcamera
AT leesejin calibrationofbrdfbasedonthefieldgoniometersystemusingauavmultispectralcamera
AT kimkyoungmin calibrationofbrdfbasedonthefieldgoniometersystemusingauavmultispectralcamera
AT limjoongbin calibrationofbrdfbasedonthefieldgoniometersystemusingauavmultispectralcamera
AT choichuluong calibrationofbrdfbasedonthefieldgoniometersystemusingauavmultispectralcamera