Cargando…

Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study

Objectives: This study aimed to determine the retentive strength of monolithic hybrid-all-ceramic crowns luted on titanium implant abutments. Material and Methods: In total, 450 crowns (75 each of Mark II, Empress CAD, e.max CAD, Suprinity, Enamic, Celtra Duo) were milled using a CAD/CAM system. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Bjelopavlovic, Monika, Weyhrauch, Michael, Scheller, Herbert, Wentaschek, Stefan, Lehmann, Karl Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9571208/
https://www.ncbi.nlm.nih.gov/pubmed/36234309
http://dx.doi.org/10.3390/ma15196968
_version_ 1784810307570368512
author Bjelopavlovic, Monika
Weyhrauch, Michael
Scheller, Herbert
Wentaschek, Stefan
Lehmann, Karl Martin
author_facet Bjelopavlovic, Monika
Weyhrauch, Michael
Scheller, Herbert
Wentaschek, Stefan
Lehmann, Karl Martin
author_sort Bjelopavlovic, Monika
collection PubMed
description Objectives: This study aimed to determine the retentive strength of monolithic hybrid-all-ceramic crowns luted on titanium implant abutments. Material and Methods: In total, 450 crowns (75 each of Mark II, Empress CAD, e.max CAD, Suprinity, Enamic, Celtra Duo) were milled using a CAD/CAM system. The crowns were cemented onto sandblasted titanium implant abutments using five luting agents (Multilink Implant, Variolink II, RelyX Unicem, Fujicem, and Panavia 2.0). After thermocycling was performed (5000 cycles: 5–55 °C, 30-s dwell time), the crowns were removed using a universal testing machine. The location of luting-agent residue on the abutment and inner crown surfaces was evaluated. Analyses of variance (ANOVA) with the Bonferroni correction were performed to evaluate differences of retentive strength depending on the crown material and the kind of the luting agent. Results: The retentive strengths for the different ceramic materials were Vita Mark II: 652N-759N (SD:134N-146N), Empress CAD: 681N-822N (SD: 89N-146N), e.max CAD: 784N-1044N (SD: 109N-176N), Vita Enamic: 716N-1177N (SD: 132N-220N), Vita Suprinity: 867N-1488N (SD: 202N-278N), and Celtra Duo 772N-1335N (SD:151N-229N). After the removal trials, the visual documentation showed different adhesive residue location depending on the ceramic materials. Furthermore, the pull-off force was dependent on the choice of adhesives. No significant differences were found between different luting agents and the ceramic material Vita Mark II and Empress CAD. EmaxCAD showed significant differences with Unicem and FujiCem compared to Panavia, as did VitaSuprinity, VitaEnamic, and Celtra Duo (p < 0.001). Conclusions: The ceramic material used seems to influence the retentive strength and the use of certain luting agents results in a higher retentive strength for some ceramic materials.
format Online
Article
Text
id pubmed-9571208
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95712082022-10-17 Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study Bjelopavlovic, Monika Weyhrauch, Michael Scheller, Herbert Wentaschek, Stefan Lehmann, Karl Martin Materials (Basel) Article Objectives: This study aimed to determine the retentive strength of monolithic hybrid-all-ceramic crowns luted on titanium implant abutments. Material and Methods: In total, 450 crowns (75 each of Mark II, Empress CAD, e.max CAD, Suprinity, Enamic, Celtra Duo) were milled using a CAD/CAM system. The crowns were cemented onto sandblasted titanium implant abutments using five luting agents (Multilink Implant, Variolink II, RelyX Unicem, Fujicem, and Panavia 2.0). After thermocycling was performed (5000 cycles: 5–55 °C, 30-s dwell time), the crowns were removed using a universal testing machine. The location of luting-agent residue on the abutment and inner crown surfaces was evaluated. Analyses of variance (ANOVA) with the Bonferroni correction were performed to evaluate differences of retentive strength depending on the crown material and the kind of the luting agent. Results: The retentive strengths for the different ceramic materials were Vita Mark II: 652N-759N (SD:134N-146N), Empress CAD: 681N-822N (SD: 89N-146N), e.max CAD: 784N-1044N (SD: 109N-176N), Vita Enamic: 716N-1177N (SD: 132N-220N), Vita Suprinity: 867N-1488N (SD: 202N-278N), and Celtra Duo 772N-1335N (SD:151N-229N). After the removal trials, the visual documentation showed different adhesive residue location depending on the ceramic materials. Furthermore, the pull-off force was dependent on the choice of adhesives. No significant differences were found between different luting agents and the ceramic material Vita Mark II and Empress CAD. EmaxCAD showed significant differences with Unicem and FujiCem compared to Panavia, as did VitaSuprinity, VitaEnamic, and Celtra Duo (p < 0.001). Conclusions: The ceramic material used seems to influence the retentive strength and the use of certain luting agents results in a higher retentive strength for some ceramic materials. MDPI 2022-10-07 /pmc/articles/PMC9571208/ /pubmed/36234309 http://dx.doi.org/10.3390/ma15196968 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bjelopavlovic, Monika
Weyhrauch, Michael
Scheller, Herbert
Wentaschek, Stefan
Lehmann, Karl Martin
Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study
title Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study
title_full Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study
title_fullStr Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study
title_full_unstemmed Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study
title_short Retentive Strength of CAD/CAM-Fabricated All-Ceramic Crowns Luted on Titanium Implant Abutments Using Different Ceramic Materials and Luting Agents: An In Vitro Study
title_sort retentive strength of cad/cam-fabricated all-ceramic crowns luted on titanium implant abutments using different ceramic materials and luting agents: an in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9571208/
https://www.ncbi.nlm.nih.gov/pubmed/36234309
http://dx.doi.org/10.3390/ma15196968
work_keys_str_mv AT bjelopavlovicmonika retentivestrengthofcadcamfabricatedallceramiccrownslutedontitaniumimplantabutmentsusingdifferentceramicmaterialsandlutingagentsaninvitrostudy
AT weyhrauchmichael retentivestrengthofcadcamfabricatedallceramiccrownslutedontitaniumimplantabutmentsusingdifferentceramicmaterialsandlutingagentsaninvitrostudy
AT schellerherbert retentivestrengthofcadcamfabricatedallceramiccrownslutedontitaniumimplantabutmentsusingdifferentceramicmaterialsandlutingagentsaninvitrostudy
AT wentaschekstefan retentivestrengthofcadcamfabricatedallceramiccrownslutedontitaniumimplantabutmentsusingdifferentceramicmaterialsandlutingagentsaninvitrostudy
AT lehmannkarlmartin retentivestrengthofcadcamfabricatedallceramiccrownslutedontitaniumimplantabutmentsusingdifferentceramicmaterialsandlutingagentsaninvitrostudy