Detecting Aflatoxin B(1) in Peanuts by Fourier Transform Near-Infrared Transmission and Diffuse Reflection Spectroscopy
Aflatioxin B(1) (AFB(1)) has been recognized by the International Agency of Research on Cancer as a group 1 carcinogen in animals and humans. A fast, batch, and real-time control and no chemical pollution method was developed for the discrimination and quantification prediction of AFB(1)-infected pe...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9571819/ https://www.ncbi.nlm.nih.gov/pubmed/36234831 http://dx.doi.org/10.3390/molecules27196294 |
Sumario: | Aflatioxin B(1) (AFB(1)) has been recognized by the International Agency of Research on Cancer as a group 1 carcinogen in animals and humans. A fast, batch, and real-time control and no chemical pollution method was developed for the discrimination and quantification prediction of AFB(1)-infected peanuts by applying Fourier transform near-infrared (FT-NIR) coupled with chemometrics. Initially, the near-infrared transmission (NIRT) and diffuse reflection (NIRR) modules were applied to collect spectra of the samples. The principal component analysis (PCA) method was employed to extract the characteristic wavelength, followed by different preprocessing methods (seven methods) to build an effective linear discriminant analysis (LDA) classification and partial least squares (PLS) quantification models. The results showed that, for both the NIRT or NIRR modules, the LDA classification models satisfactorily distinguished peanuts infected with AFB(1) or from those not infected, with external validation showing a 100% correct identification rate and a 0% misjudgment rate. In addition, combined with the concentration of AFB(1) in peanuts determined by enzyme-linked immunoassay assay, the best partial least squares (PLS) models were established, with a combination of the first derivative and the Norris derivative filter smoothing pretreatment (R(c)(2) = 0.937 and 0.984, RMSECV = 3.92% and 2.22%, RPD = 3.98 and 7.91 for NIRR and NIRT, respectively). The correlation coefficient between the predicted value and the reference value in the external verification was 0.998 and 0.917, respectively. This study highlights that both spectral acquisition modules meet the requirements of online, rapid, and accurate identification of peanut AFB(1) infection in the early stages. |
---|