Cargando…
Calibration of SO(2) and NO(2) Electrochemical Sensors via a Training and Testing Method in an Industrial Coastal Environment
Low-cost sensors can provide inaccurate data as temperature and humidity affect sensor accuracy. Therefore, calibration and data correction are essential to obtain reliable measurements. This article presents a training and testing method used to calibrate a sensor module assembled from SO(2) and NO...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572153/ https://www.ncbi.nlm.nih.gov/pubmed/36236383 http://dx.doi.org/10.3390/s22197281 |
_version_ | 1784810542263697408 |
---|---|
author | Ahumada, Sofía Tagle, Matias Vasquez, Yeanice Donoso, Rodrigo Lindén, Jenny Hallgren, Fredrik Segura, Marta Oyola, Pedro |
author_facet | Ahumada, Sofía Tagle, Matias Vasquez, Yeanice Donoso, Rodrigo Lindén, Jenny Hallgren, Fredrik Segura, Marta Oyola, Pedro |
author_sort | Ahumada, Sofía |
collection | PubMed |
description | Low-cost sensors can provide inaccurate data as temperature and humidity affect sensor accuracy. Therefore, calibration and data correction are essential to obtain reliable measurements. This article presents a training and testing method used to calibrate a sensor module assembled from SO(2) and NO(2) electrochemical sensors (Alphasense B4 and B43F) alongside air temperature (T) and humidity (RH) sensors. Field training and testing were conducted in the industrialized coastal area of Quintero Bay, Chile. The raw responses of the electrochemical (mV) and T-RH sensors were subjected to multiple linear regression (MLR) using three data segments, based on either voltage (SO(2) sensor) or temperature (NO(2)). The resulting MLR equations were used to estimate the reference concentration. In the field test, calibration improved the performance of the sensors after adding T and RH in a linear model. The most robust models for NO(2) were associated with data collected at T < 10 °C (R(2) = 0.85), while SO(2) robust models (R(2) = 0.97) were associated with data segments containing higher voltages. Overall, this training and testing method reduced the bias due to T and HR in the evaluated sensors and could be replicated in similar environments to correct raw data from low-cost electrochemical sensors. A calibration method based on training and sensor testing after relocation is presented. The results show that the SO(2) sensor performed better when modeled for different segments of voltage data, and the NO(2) sensor model performed better when calibrated for different temperature data segments. |
format | Online Article Text |
id | pubmed-9572153 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95721532022-10-17 Calibration of SO(2) and NO(2) Electrochemical Sensors via a Training and Testing Method in an Industrial Coastal Environment Ahumada, Sofía Tagle, Matias Vasquez, Yeanice Donoso, Rodrigo Lindén, Jenny Hallgren, Fredrik Segura, Marta Oyola, Pedro Sensors (Basel) Article Low-cost sensors can provide inaccurate data as temperature and humidity affect sensor accuracy. Therefore, calibration and data correction are essential to obtain reliable measurements. This article presents a training and testing method used to calibrate a sensor module assembled from SO(2) and NO(2) electrochemical sensors (Alphasense B4 and B43F) alongside air temperature (T) and humidity (RH) sensors. Field training and testing were conducted in the industrialized coastal area of Quintero Bay, Chile. The raw responses of the electrochemical (mV) and T-RH sensors were subjected to multiple linear regression (MLR) using three data segments, based on either voltage (SO(2) sensor) or temperature (NO(2)). The resulting MLR equations were used to estimate the reference concentration. In the field test, calibration improved the performance of the sensors after adding T and RH in a linear model. The most robust models for NO(2) were associated with data collected at T < 10 °C (R(2) = 0.85), while SO(2) robust models (R(2) = 0.97) were associated with data segments containing higher voltages. Overall, this training and testing method reduced the bias due to T and HR in the evaluated sensors and could be replicated in similar environments to correct raw data from low-cost electrochemical sensors. A calibration method based on training and sensor testing after relocation is presented. The results show that the SO(2) sensor performed better when modeled for different segments of voltage data, and the NO(2) sensor model performed better when calibrated for different temperature data segments. MDPI 2022-09-26 /pmc/articles/PMC9572153/ /pubmed/36236383 http://dx.doi.org/10.3390/s22197281 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ahumada, Sofía Tagle, Matias Vasquez, Yeanice Donoso, Rodrigo Lindén, Jenny Hallgren, Fredrik Segura, Marta Oyola, Pedro Calibration of SO(2) and NO(2) Electrochemical Sensors via a Training and Testing Method in an Industrial Coastal Environment |
title | Calibration of SO(2) and NO(2) Electrochemical Sensors via a Training and Testing Method in an Industrial Coastal Environment |
title_full | Calibration of SO(2) and NO(2) Electrochemical Sensors via a Training and Testing Method in an Industrial Coastal Environment |
title_fullStr | Calibration of SO(2) and NO(2) Electrochemical Sensors via a Training and Testing Method in an Industrial Coastal Environment |
title_full_unstemmed | Calibration of SO(2) and NO(2) Electrochemical Sensors via a Training and Testing Method in an Industrial Coastal Environment |
title_short | Calibration of SO(2) and NO(2) Electrochemical Sensors via a Training and Testing Method in an Industrial Coastal Environment |
title_sort | calibration of so(2) and no(2) electrochemical sensors via a training and testing method in an industrial coastal environment |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572153/ https://www.ncbi.nlm.nih.gov/pubmed/36236383 http://dx.doi.org/10.3390/s22197281 |
work_keys_str_mv | AT ahumadasofia calibrationofso2andno2electrochemicalsensorsviaatrainingandtestingmethodinanindustrialcoastalenvironment AT taglematias calibrationofso2andno2electrochemicalsensorsviaatrainingandtestingmethodinanindustrialcoastalenvironment AT vasquezyeanice calibrationofso2andno2electrochemicalsensorsviaatrainingandtestingmethodinanindustrialcoastalenvironment AT donosorodrigo calibrationofso2andno2electrochemicalsensorsviaatrainingandtestingmethodinanindustrialcoastalenvironment AT lindenjenny calibrationofso2andno2electrochemicalsensorsviaatrainingandtestingmethodinanindustrialcoastalenvironment AT hallgrenfredrik calibrationofso2andno2electrochemicalsensorsviaatrainingandtestingmethodinanindustrialcoastalenvironment AT seguramarta calibrationofso2andno2electrochemicalsensorsviaatrainingandtestingmethodinanindustrialcoastalenvironment AT oyolapedro calibrationofso2andno2electrochemicalsensorsviaatrainingandtestingmethodinanindustrialcoastalenvironment |