Cargando…

Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography

The aim of this study was to analyze retinal nerve fiber layer (RNFL) thickness after trabeculectomy (TE) versus XEN microstent implantation (XEN) in primary open-angle glaucoma (POAG) cases naïve to prior incisional glaucoma surgery. We examined 119 consecutive glaucoma patients retrospectively, wh...

Descripción completa

Detalles Bibliográficos
Autores principales: Bormann, Caroline, Busch, Catharina, Rehak, Matus, Schmidt, Manuela, Scharenberg, Christian, Ziemssen, Focke, Unterlauft, Jan Darius
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572517/
https://www.ncbi.nlm.nih.gov/pubmed/36233707
http://dx.doi.org/10.3390/jcm11195840
_version_ 1784810634886512640
author Bormann, Caroline
Busch, Catharina
Rehak, Matus
Schmidt, Manuela
Scharenberg, Christian
Ziemssen, Focke
Unterlauft, Jan Darius
author_facet Bormann, Caroline
Busch, Catharina
Rehak, Matus
Schmidt, Manuela
Scharenberg, Christian
Ziemssen, Focke
Unterlauft, Jan Darius
author_sort Bormann, Caroline
collection PubMed
description The aim of this study was to analyze retinal nerve fiber layer (RNFL) thickness after trabeculectomy (TE) versus XEN microstent implantation (XEN) in primary open-angle glaucoma (POAG) cases naïve to prior incisional glaucoma surgery. We examined 119 consecutive glaucoma patients retrospectively, who received a TE or XEN for medically uncontrolled POAG. Intraocular pressure (IOP), amount of IOP-lowering medication, mean deviation of standard automated perimetry and peripapillary RNFL thickness were evaluated during the first 24 months after surgery. Fifty eyes were treated with TE and 69 eyes with XEN. Mean IOP decreased from 25.1 ± 0.8 to 13.3 ± 0.6 mm Hg (p < 0.01) and mean number of IOP-lowering eye drops from 3.2 ± 0.2 to 0.4 ± 0.1 (p < 0.01) 24 months after TE. In 69 eyes undergoing XEN, mean IOP dropped from 24.8 ± 0.6 to 15.0 ± 0.4 mm Hg (p < 0.01) and medication from 3.0 ± 0.1 to 0.6 ± 0.1 (p < 0.01) during the 24 months follow-up. Mean deviation of standard automated perimetry remained stable in TE (8.5 ± 0.7 to 8.1 ± 0.8 dB; p = 0.54) and XEN group (11,0 ± 0.5 to 11.5 ± 0.5 dB; p = 0.12) after 24 months, while mean RNFL thickness further deteriorated in the TE (−2.28 ± 0.65 µm/year) and XEN (−0.68 ± 0.34 µm/year) group. Postoperative RNFL loss develops after TE and XEN despite effective and significant lowering of IOP and amount of IOP-lowering medication. RNFL loss was more pronounced in the first year after glaucoma surgery.
format Online
Article
Text
id pubmed-9572517
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95725172022-10-17 Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography Bormann, Caroline Busch, Catharina Rehak, Matus Schmidt, Manuela Scharenberg, Christian Ziemssen, Focke Unterlauft, Jan Darius J Clin Med Article The aim of this study was to analyze retinal nerve fiber layer (RNFL) thickness after trabeculectomy (TE) versus XEN microstent implantation (XEN) in primary open-angle glaucoma (POAG) cases naïve to prior incisional glaucoma surgery. We examined 119 consecutive glaucoma patients retrospectively, who received a TE or XEN for medically uncontrolled POAG. Intraocular pressure (IOP), amount of IOP-lowering medication, mean deviation of standard automated perimetry and peripapillary RNFL thickness were evaluated during the first 24 months after surgery. Fifty eyes were treated with TE and 69 eyes with XEN. Mean IOP decreased from 25.1 ± 0.8 to 13.3 ± 0.6 mm Hg (p < 0.01) and mean number of IOP-lowering eye drops from 3.2 ± 0.2 to 0.4 ± 0.1 (p < 0.01) 24 months after TE. In 69 eyes undergoing XEN, mean IOP dropped from 24.8 ± 0.6 to 15.0 ± 0.4 mm Hg (p < 0.01) and medication from 3.0 ± 0.1 to 0.6 ± 0.1 (p < 0.01) during the 24 months follow-up. Mean deviation of standard automated perimetry remained stable in TE (8.5 ± 0.7 to 8.1 ± 0.8 dB; p = 0.54) and XEN group (11,0 ± 0.5 to 11.5 ± 0.5 dB; p = 0.12) after 24 months, while mean RNFL thickness further deteriorated in the TE (−2.28 ± 0.65 µm/year) and XEN (−0.68 ± 0.34 µm/year) group. Postoperative RNFL loss develops after TE and XEN despite effective and significant lowering of IOP and amount of IOP-lowering medication. RNFL loss was more pronounced in the first year after glaucoma surgery. MDPI 2022-10-01 /pmc/articles/PMC9572517/ /pubmed/36233707 http://dx.doi.org/10.3390/jcm11195840 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bormann, Caroline
Busch, Catharina
Rehak, Matus
Schmidt, Manuela
Scharenberg, Christian
Ziemssen, Focke
Unterlauft, Jan Darius
Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography
title Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography
title_full Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography
title_fullStr Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography
title_full_unstemmed Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography
title_short Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography
title_sort two year functional and structural changes—a comparison between trabeculectomy and xen microstent implantation using spectral domain optical coherence tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572517/
https://www.ncbi.nlm.nih.gov/pubmed/36233707
http://dx.doi.org/10.3390/jcm11195840
work_keys_str_mv AT bormanncaroline twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography
AT buschcatharina twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography
AT rehakmatus twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography
AT schmidtmanuela twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography
AT scharenbergchristian twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography
AT ziemssenfocke twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography
AT unterlauftjandarius twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography