Cargando…
Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography
The aim of this study was to analyze retinal nerve fiber layer (RNFL) thickness after trabeculectomy (TE) versus XEN microstent implantation (XEN) in primary open-angle glaucoma (POAG) cases naïve to prior incisional glaucoma surgery. We examined 119 consecutive glaucoma patients retrospectively, wh...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572517/ https://www.ncbi.nlm.nih.gov/pubmed/36233707 http://dx.doi.org/10.3390/jcm11195840 |
_version_ | 1784810634886512640 |
---|---|
author | Bormann, Caroline Busch, Catharina Rehak, Matus Schmidt, Manuela Scharenberg, Christian Ziemssen, Focke Unterlauft, Jan Darius |
author_facet | Bormann, Caroline Busch, Catharina Rehak, Matus Schmidt, Manuela Scharenberg, Christian Ziemssen, Focke Unterlauft, Jan Darius |
author_sort | Bormann, Caroline |
collection | PubMed |
description | The aim of this study was to analyze retinal nerve fiber layer (RNFL) thickness after trabeculectomy (TE) versus XEN microstent implantation (XEN) in primary open-angle glaucoma (POAG) cases naïve to prior incisional glaucoma surgery. We examined 119 consecutive glaucoma patients retrospectively, who received a TE or XEN for medically uncontrolled POAG. Intraocular pressure (IOP), amount of IOP-lowering medication, mean deviation of standard automated perimetry and peripapillary RNFL thickness were evaluated during the first 24 months after surgery. Fifty eyes were treated with TE and 69 eyes with XEN. Mean IOP decreased from 25.1 ± 0.8 to 13.3 ± 0.6 mm Hg (p < 0.01) and mean number of IOP-lowering eye drops from 3.2 ± 0.2 to 0.4 ± 0.1 (p < 0.01) 24 months after TE. In 69 eyes undergoing XEN, mean IOP dropped from 24.8 ± 0.6 to 15.0 ± 0.4 mm Hg (p < 0.01) and medication from 3.0 ± 0.1 to 0.6 ± 0.1 (p < 0.01) during the 24 months follow-up. Mean deviation of standard automated perimetry remained stable in TE (8.5 ± 0.7 to 8.1 ± 0.8 dB; p = 0.54) and XEN group (11,0 ± 0.5 to 11.5 ± 0.5 dB; p = 0.12) after 24 months, while mean RNFL thickness further deteriorated in the TE (−2.28 ± 0.65 µm/year) and XEN (−0.68 ± 0.34 µm/year) group. Postoperative RNFL loss develops after TE and XEN despite effective and significant lowering of IOP and amount of IOP-lowering medication. RNFL loss was more pronounced in the first year after glaucoma surgery. |
format | Online Article Text |
id | pubmed-9572517 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95725172022-10-17 Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography Bormann, Caroline Busch, Catharina Rehak, Matus Schmidt, Manuela Scharenberg, Christian Ziemssen, Focke Unterlauft, Jan Darius J Clin Med Article The aim of this study was to analyze retinal nerve fiber layer (RNFL) thickness after trabeculectomy (TE) versus XEN microstent implantation (XEN) in primary open-angle glaucoma (POAG) cases naïve to prior incisional glaucoma surgery. We examined 119 consecutive glaucoma patients retrospectively, who received a TE or XEN for medically uncontrolled POAG. Intraocular pressure (IOP), amount of IOP-lowering medication, mean deviation of standard automated perimetry and peripapillary RNFL thickness were evaluated during the first 24 months after surgery. Fifty eyes were treated with TE and 69 eyes with XEN. Mean IOP decreased from 25.1 ± 0.8 to 13.3 ± 0.6 mm Hg (p < 0.01) and mean number of IOP-lowering eye drops from 3.2 ± 0.2 to 0.4 ± 0.1 (p < 0.01) 24 months after TE. In 69 eyes undergoing XEN, mean IOP dropped from 24.8 ± 0.6 to 15.0 ± 0.4 mm Hg (p < 0.01) and medication from 3.0 ± 0.1 to 0.6 ± 0.1 (p < 0.01) during the 24 months follow-up. Mean deviation of standard automated perimetry remained stable in TE (8.5 ± 0.7 to 8.1 ± 0.8 dB; p = 0.54) and XEN group (11,0 ± 0.5 to 11.5 ± 0.5 dB; p = 0.12) after 24 months, while mean RNFL thickness further deteriorated in the TE (−2.28 ± 0.65 µm/year) and XEN (−0.68 ± 0.34 µm/year) group. Postoperative RNFL loss develops after TE and XEN despite effective and significant lowering of IOP and amount of IOP-lowering medication. RNFL loss was more pronounced in the first year after glaucoma surgery. MDPI 2022-10-01 /pmc/articles/PMC9572517/ /pubmed/36233707 http://dx.doi.org/10.3390/jcm11195840 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Bormann, Caroline Busch, Catharina Rehak, Matus Schmidt, Manuela Scharenberg, Christian Ziemssen, Focke Unterlauft, Jan Darius Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography |
title | Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography |
title_full | Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography |
title_fullStr | Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography |
title_full_unstemmed | Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography |
title_short | Two Year Functional and Structural Changes—A Comparison between Trabeculectomy and XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography |
title_sort | two year functional and structural changes—a comparison between trabeculectomy and xen microstent implantation using spectral domain optical coherence tomography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572517/ https://www.ncbi.nlm.nih.gov/pubmed/36233707 http://dx.doi.org/10.3390/jcm11195840 |
work_keys_str_mv | AT bormanncaroline twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography AT buschcatharina twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography AT rehakmatus twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography AT schmidtmanuela twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography AT scharenbergchristian twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography AT ziemssenfocke twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography AT unterlauftjandarius twoyearfunctionalandstructuralchangesacomparisonbetweentrabeculectomyandxenmicrostentimplantationusingspectraldomainopticalcoherencetomography |