Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings
In order to improve the construction efficiency of piers and reduce the local damage of piers, concrete-filled steel tubes (CFST) are used to precast pier segments. Aiming at the problems of the poor integrity and insufficient energy dissipation capacity of dry joint segmental assembled piers, segme...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572677/ https://www.ncbi.nlm.nih.gov/pubmed/36234334 http://dx.doi.org/10.3390/ma15196993 |
_version_ | 1784810675501006848 |
---|---|
author | Wang, Chengquan Qu, Zheng Shen, Yonggang Jiang, Jiqing Yin, Chongli Zong, Yanwei |
author_facet | Wang, Chengquan Qu, Zheng Shen, Yonggang Jiang, Jiqing Yin, Chongli Zong, Yanwei |
author_sort | Wang, Chengquan |
collection | PubMed |
description | In order to improve the construction efficiency of piers and reduce the local damage of piers, concrete-filled steel tubes (CFST) are used to precast pier segments. Aiming at the problems of the poor integrity and insufficient energy dissipation capacity of dry joint segmental assembled piers, segmental assembled concrete-filled steel tubular piers with external replaceable energy dissipators are being developed. Based on the low cyclic test of a segmental assembled CFST pier, the finite element numerical simulation model of a CFST pier is established based on ABAQUS software, and the validity of the numerical model is verified by the experimental results. The effects of the section ratio, axial compression ratio, and initial prestress on the seismic performance of piers are studied through a pseudostatic analysis. The results show that an increase in the section ratio can improve the lateral bearing capacity and energy dissipation capacity of the pier. When the section ratio is increased to 4%, the energy dissipation capacity of a CFST pier is increased by 77.8% and the lateral bearing capacity is increased by 33.9% compared with a section ratio of 2%, but the residual displacement of the pier top also increases. With an increase in the axial compression ratio, the energy dissipation capacity of the pier is significantly improved; when the axial compression ratio is increased to 0.30, the energy dissipation capacity of CFST piers is increased by 27.5% compared with a section ratio of 0.05, the residual displacement of the pier top is reduced, and the self-resetting effect of the pier is improved. A change in the initial prestress has no effect on the energy dissipation capacity of piers. Finally, based on an analysis of mechanical theory, a formula of bending capacity suitable for this type of pier is proposed, and the error is within 10%. |
format | Online Article Text |
id | pubmed-9572677 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95726772022-10-17 Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings Wang, Chengquan Qu, Zheng Shen, Yonggang Jiang, Jiqing Yin, Chongli Zong, Yanwei Materials (Basel) Article In order to improve the construction efficiency of piers and reduce the local damage of piers, concrete-filled steel tubes (CFST) are used to precast pier segments. Aiming at the problems of the poor integrity and insufficient energy dissipation capacity of dry joint segmental assembled piers, segmental assembled concrete-filled steel tubular piers with external replaceable energy dissipators are being developed. Based on the low cyclic test of a segmental assembled CFST pier, the finite element numerical simulation model of a CFST pier is established based on ABAQUS software, and the validity of the numerical model is verified by the experimental results. The effects of the section ratio, axial compression ratio, and initial prestress on the seismic performance of piers are studied through a pseudostatic analysis. The results show that an increase in the section ratio can improve the lateral bearing capacity and energy dissipation capacity of the pier. When the section ratio is increased to 4%, the energy dissipation capacity of a CFST pier is increased by 77.8% and the lateral bearing capacity is increased by 33.9% compared with a section ratio of 2%, but the residual displacement of the pier top also increases. With an increase in the axial compression ratio, the energy dissipation capacity of the pier is significantly improved; when the axial compression ratio is increased to 0.30, the energy dissipation capacity of CFST piers is increased by 27.5% compared with a section ratio of 0.05, the residual displacement of the pier top is reduced, and the self-resetting effect of the pier is improved. A change in the initial prestress has no effect on the energy dissipation capacity of piers. Finally, based on an analysis of mechanical theory, a formula of bending capacity suitable for this type of pier is proposed, and the error is within 10%. MDPI 2022-10-09 /pmc/articles/PMC9572677/ /pubmed/36234334 http://dx.doi.org/10.3390/ma15196993 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Chengquan Qu, Zheng Shen, Yonggang Jiang, Jiqing Yin, Chongli Zong, Yanwei Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings |
title | Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings |
title_full | Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings |
title_fullStr | Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings |
title_full_unstemmed | Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings |
title_short | Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings |
title_sort | numerical investigation of the performance of segmental cfst piers with external energy dissipators under lateral cyclic loadings |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572677/ https://www.ncbi.nlm.nih.gov/pubmed/36234334 http://dx.doi.org/10.3390/ma15196993 |
work_keys_str_mv | AT wangchengquan numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings AT quzheng numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings AT shenyonggang numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings AT jiangjiqing numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings AT yinchongli numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings AT zongyanwei numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings |