Cargando…

Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings

In order to improve the construction efficiency of piers and reduce the local damage of piers, concrete-filled steel tubes (CFST) are used to precast pier segments. Aiming at the problems of the poor integrity and insufficient energy dissipation capacity of dry joint segmental assembled piers, segme...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Chengquan, Qu, Zheng, Shen, Yonggang, Jiang, Jiqing, Yin, Chongli, Zong, Yanwei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572677/
https://www.ncbi.nlm.nih.gov/pubmed/36234334
http://dx.doi.org/10.3390/ma15196993
_version_ 1784810675501006848
author Wang, Chengquan
Qu, Zheng
Shen, Yonggang
Jiang, Jiqing
Yin, Chongli
Zong, Yanwei
author_facet Wang, Chengquan
Qu, Zheng
Shen, Yonggang
Jiang, Jiqing
Yin, Chongli
Zong, Yanwei
author_sort Wang, Chengquan
collection PubMed
description In order to improve the construction efficiency of piers and reduce the local damage of piers, concrete-filled steel tubes (CFST) are used to precast pier segments. Aiming at the problems of the poor integrity and insufficient energy dissipation capacity of dry joint segmental assembled piers, segmental assembled concrete-filled steel tubular piers with external replaceable energy dissipators are being developed. Based on the low cyclic test of a segmental assembled CFST pier, the finite element numerical simulation model of a CFST pier is established based on ABAQUS software, and the validity of the numerical model is verified by the experimental results. The effects of the section ratio, axial compression ratio, and initial prestress on the seismic performance of piers are studied through a pseudostatic analysis. The results show that an increase in the section ratio can improve the lateral bearing capacity and energy dissipation capacity of the pier. When the section ratio is increased to 4%, the energy dissipation capacity of a CFST pier is increased by 77.8% and the lateral bearing capacity is increased by 33.9% compared with a section ratio of 2%, but the residual displacement of the pier top also increases. With an increase in the axial compression ratio, the energy dissipation capacity of the pier is significantly improved; when the axial compression ratio is increased to 0.30, the energy dissipation capacity of CFST piers is increased by 27.5% compared with a section ratio of 0.05, the residual displacement of the pier top is reduced, and the self-resetting effect of the pier is improved. A change in the initial prestress has no effect on the energy dissipation capacity of piers. Finally, based on an analysis of mechanical theory, a formula of bending capacity suitable for this type of pier is proposed, and the error is within 10%.
format Online
Article
Text
id pubmed-9572677
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95726772022-10-17 Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings Wang, Chengquan Qu, Zheng Shen, Yonggang Jiang, Jiqing Yin, Chongli Zong, Yanwei Materials (Basel) Article In order to improve the construction efficiency of piers and reduce the local damage of piers, concrete-filled steel tubes (CFST) are used to precast pier segments. Aiming at the problems of the poor integrity and insufficient energy dissipation capacity of dry joint segmental assembled piers, segmental assembled concrete-filled steel tubular piers with external replaceable energy dissipators are being developed. Based on the low cyclic test of a segmental assembled CFST pier, the finite element numerical simulation model of a CFST pier is established based on ABAQUS software, and the validity of the numerical model is verified by the experimental results. The effects of the section ratio, axial compression ratio, and initial prestress on the seismic performance of piers are studied through a pseudostatic analysis. The results show that an increase in the section ratio can improve the lateral bearing capacity and energy dissipation capacity of the pier. When the section ratio is increased to 4%, the energy dissipation capacity of a CFST pier is increased by 77.8% and the lateral bearing capacity is increased by 33.9% compared with a section ratio of 2%, but the residual displacement of the pier top also increases. With an increase in the axial compression ratio, the energy dissipation capacity of the pier is significantly improved; when the axial compression ratio is increased to 0.30, the energy dissipation capacity of CFST piers is increased by 27.5% compared with a section ratio of 0.05, the residual displacement of the pier top is reduced, and the self-resetting effect of the pier is improved. A change in the initial prestress has no effect on the energy dissipation capacity of piers. Finally, based on an analysis of mechanical theory, a formula of bending capacity suitable for this type of pier is proposed, and the error is within 10%. MDPI 2022-10-09 /pmc/articles/PMC9572677/ /pubmed/36234334 http://dx.doi.org/10.3390/ma15196993 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Chengquan
Qu, Zheng
Shen, Yonggang
Jiang, Jiqing
Yin, Chongli
Zong, Yanwei
Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings
title Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings
title_full Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings
title_fullStr Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings
title_full_unstemmed Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings
title_short Numerical Investigation of the Performance of Segmental CFST Piers with External Energy Dissipators under Lateral Cyclic Loadings
title_sort numerical investigation of the performance of segmental cfst piers with external energy dissipators under lateral cyclic loadings
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572677/
https://www.ncbi.nlm.nih.gov/pubmed/36234334
http://dx.doi.org/10.3390/ma15196993
work_keys_str_mv AT wangchengquan numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings
AT quzheng numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings
AT shenyonggang numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings
AT jiangjiqing numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings
AT yinchongli numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings
AT zongyanwei numericalinvestigationoftheperformanceofsegmentalcfstpierswithexternalenergydissipatorsunderlateralcyclicloadings