High-Performance pH Sensor Electrodes Based on a Hexagonal Pt Nanoparticle Array-Coated Nanoporous Alumina Membrane
Porous anodic alumina membranes coated with Pt nanoparticles (PAAM/Pt) have been employed as pH sensor electrodes for H(+) ion detection. The PAAM was designed using a two-step anodization process. Pt nanoparticles were then sputtered onto the membrane at different deposition times. The membrane’s m...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572877/ https://www.ncbi.nlm.nih.gov/pubmed/36233854 http://dx.doi.org/10.3390/ma15196515 |
_version_ | 1784810726834044928 |
---|---|
author | Altowyan, Abeer S. Shaban, Mohamed Gamel, Asmaa Gamal, Ahmed Ali, Mona Rabia, Mohamed |
author_facet | Altowyan, Abeer S. Shaban, Mohamed Gamel, Asmaa Gamal, Ahmed Ali, Mona Rabia, Mohamed |
author_sort | Altowyan, Abeer S. |
collection | PubMed |
description | Porous anodic alumina membranes coated with Pt nanoparticles (PAAM/Pt) have been employed as pH sensor electrodes for H(+) ion detection. The PAAM was designed using a two-step anodization process. Pt nanoparticles were then sputtered onto the membrane at different deposition times. The membrane’s morphological, chemical, and optical characteristics were carefully assessed following the fabrication stage using a variety of analytical techniques. The potential of the PAAM/Pt sensor electrode was investigated by measuring the potential using a simple potentiometric method. The effects of depositing Pt nanoparticles for 3–7 min on sensor electrode sensitivity were examined. The optimal potentiometric Nernstian response slope for the PAAM/Pt sensor electrode with 5 min Pt sputter coating is 56.31 mV/decade in the pH range of 3.0 to 10 at 293 K. Additionally, the PAAM/Pt sensor electrode’s stability and selectivity in various ions solutions were examined. The sensor electrode had a lifetime of more than six weeks and was kept in a normal air environment. |
format | Online Article Text |
id | pubmed-9572877 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95728772022-10-17 High-Performance pH Sensor Electrodes Based on a Hexagonal Pt Nanoparticle Array-Coated Nanoporous Alumina Membrane Altowyan, Abeer S. Shaban, Mohamed Gamel, Asmaa Gamal, Ahmed Ali, Mona Rabia, Mohamed Materials (Basel) Article Porous anodic alumina membranes coated with Pt nanoparticles (PAAM/Pt) have been employed as pH sensor electrodes for H(+) ion detection. The PAAM was designed using a two-step anodization process. Pt nanoparticles were then sputtered onto the membrane at different deposition times. The membrane’s morphological, chemical, and optical characteristics were carefully assessed following the fabrication stage using a variety of analytical techniques. The potential of the PAAM/Pt sensor electrode was investigated by measuring the potential using a simple potentiometric method. The effects of depositing Pt nanoparticles for 3–7 min on sensor electrode sensitivity were examined. The optimal potentiometric Nernstian response slope for the PAAM/Pt sensor electrode with 5 min Pt sputter coating is 56.31 mV/decade in the pH range of 3.0 to 10 at 293 K. Additionally, the PAAM/Pt sensor electrode’s stability and selectivity in various ions solutions were examined. The sensor electrode had a lifetime of more than six weeks and was kept in a normal air environment. MDPI 2022-09-20 /pmc/articles/PMC9572877/ /pubmed/36233854 http://dx.doi.org/10.3390/ma15196515 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Altowyan, Abeer S. Shaban, Mohamed Gamel, Asmaa Gamal, Ahmed Ali, Mona Rabia, Mohamed High-Performance pH Sensor Electrodes Based on a Hexagonal Pt Nanoparticle Array-Coated Nanoporous Alumina Membrane |
title | High-Performance pH Sensor Electrodes Based on a Hexagonal Pt Nanoparticle Array-Coated Nanoporous Alumina Membrane |
title_full | High-Performance pH Sensor Electrodes Based on a Hexagonal Pt Nanoparticle Array-Coated Nanoporous Alumina Membrane |
title_fullStr | High-Performance pH Sensor Electrodes Based on a Hexagonal Pt Nanoparticle Array-Coated Nanoporous Alumina Membrane |
title_full_unstemmed | High-Performance pH Sensor Electrodes Based on a Hexagonal Pt Nanoparticle Array-Coated Nanoporous Alumina Membrane |
title_short | High-Performance pH Sensor Electrodes Based on a Hexagonal Pt Nanoparticle Array-Coated Nanoporous Alumina Membrane |
title_sort | high-performance ph sensor electrodes based on a hexagonal pt nanoparticle array-coated nanoporous alumina membrane |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9572877/ https://www.ncbi.nlm.nih.gov/pubmed/36233854 http://dx.doi.org/10.3390/ma15196515 |
work_keys_str_mv | AT altowyanabeers highperformancephsensorelectrodesbasedonahexagonalptnanoparticlearraycoatednanoporousaluminamembrane AT shabanmohamed highperformancephsensorelectrodesbasedonahexagonalptnanoparticlearraycoatednanoporousaluminamembrane AT gamelasmaa highperformancephsensorelectrodesbasedonahexagonalptnanoparticlearraycoatednanoporousaluminamembrane AT gamalahmed highperformancephsensorelectrodesbasedonahexagonalptnanoparticlearraycoatednanoporousaluminamembrane AT alimona highperformancephsensorelectrodesbasedonahexagonalptnanoparticlearraycoatednanoporousaluminamembrane AT rabiamohamed highperformancephsensorelectrodesbasedonahexagonalptnanoparticlearraycoatednanoporousaluminamembrane |