Cargando…

The Effects of Device-Based Cardiac Contractility Modulation Therapy on Left Ventricle Global Longitudinal Strain and Myocardial Mechano-Energetic Efficiency in Patients with Heart Failure with Reduced Ejection Fraction

Background: Virtually all patients with heart failure with reduced ejection fraction have a reduction of myocardial mechano-energetic efficiency (MEE). Cardiac contractility modulation (CCM) is a novel therapy for the treatment of patients with HFrEF, in whom it improves the quality of life and func...

Descripción completa

Detalles Bibliográficos
Autores principales: Masarone, Daniele, Kittleson, Michelle M., De Vivo, Stefano, D’Onofrio, Antonio, Ammendola, Ernesto, Nigro, Gerardo, Contaldi, Carla, Martucci, Maria L., Errigo, Vittoria, Pacileo, Giuseppe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9573486/
https://www.ncbi.nlm.nih.gov/pubmed/36233734
http://dx.doi.org/10.3390/jcm11195866
Descripción
Sumario:Background: Virtually all patients with heart failure with reduced ejection fraction have a reduction of myocardial mechano-energetic efficiency (MEE). Cardiac contractility modulation (CCM) is a novel therapy for the treatment of patients with HFrEF, in whom it improves the quality of life and functional capacity, reduces hospitalizations, and induces biventricular reverse remodeling. However, the effects of CCM on MEE and global longitudinal strain (GLS) are still unknown; therefore, this study aims to evaluate whether CCM therapy can improve the MEE of patients with HFrEF. Methods: We enrolled 25 patients with HFrEF who received an Optimizer Smart implant (the device that develops CCM therapy) between January 2018 and January 2021. Clinical and echocardiographic evaluations were performed in all patients 24 h before and six months after CCM therapy. Results: At six months, follow-up patients who underwent CCM therapy showed an increase of left ventricular ejection fraction (30.8 ± 7.1 vs. 36.1 ± 6.9%; p = 0.032) as well a rise of GLS 10.3 ± 2.7 vs. −12.9 ± 4.2; p = 0.018), of MEE (32.2 ± 10.1 vs. 38.6 ± 7.6 mL/s; p = 0.013) and of MEE index (18.4 ± 6.3 vs. 24.3 ± 6.7 mL/s/g; p = 0.022). Conclusions: CCM therapy increased left ventricular performance, improving left ventricular ejection fraction, GLS, as well as MEE and MEEi.