Cargando…
Measurement-Error Analysis of Fiber Bragg Grating Flexible Sensor for Displacement-Field Monitoring of Geotechnical Engineering
Monitoring geotechnical structures and providing real-time early warning is a key measure to mitigate the impacts of disasters (slope slip, subsidence, dam deformation, bridge settlement, etc.). The fiber Bragg grating (FBG) flexible sensor, developed by the combination of flexible material and an F...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9573560/ https://www.ncbi.nlm.nih.gov/pubmed/36236277 http://dx.doi.org/10.3390/s22197168 |
_version_ | 1784810902991667200 |
---|---|
author | Tian, Changbin Ma, Xiangxue Peng, Bo Ma, Xin Li, Zhiyu |
author_facet | Tian, Changbin Ma, Xiangxue Peng, Bo Ma, Xin Li, Zhiyu |
author_sort | Tian, Changbin |
collection | PubMed |
description | Monitoring geotechnical structures and providing real-time early warning is a key measure to mitigate the impacts of disasters (slope slip, subsidence, dam deformation, bridge settlement, etc.). The fiber Bragg grating (FBG) flexible sensor, developed by the combination of flexible material and an FBG sensor, is widely used in geotechnical engineering health monitoring due to its excellent performance. The flexible sensor can perform regional and quasi-distributed measurements of the displacement field of the measured structure, and accurately reflect the operating state of the engineering structure. However, in practical engineering applications, factors such as the strain-transfer rate between the flexible substrate and sensing points, the displacement reconstruction algorithm, and the arrangement interval of the sensing points can cause measurement error, which, in turn, leads to a decrease in the displacement-measurement accuracy. In this paper, the following analysis is performed by means of theoretical derivation and model establishment. The influence of the length, width, and thickness of the cemented layer, the shear modulus of the flexible substrate, and the radius of the groove on the strain-transfer rate were analyzed, and the referential parameters were determined. The displacement reconstruction algorithm is essentially a recursive algorithm, which inevitably introduces cumulative error; the relationship between the layout interval of the sensing points and the measurement error is discussed. Considering the fabrication cost of the sensor and the allowable range of error, a sensing-point-layout interval of 100 mm was chosen. The feasibility and effectiveness of the simulation theory were verified by carrying out deformation-sensing experiments on the developed FBG flexible sensor. The research results can theoretically guide the packaging and fabrication of the FBG flexible sensor, thereby improving the measurement accuracy of the flexible sensor for the measured structure. |
format | Online Article Text |
id | pubmed-9573560 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95735602022-10-17 Measurement-Error Analysis of Fiber Bragg Grating Flexible Sensor for Displacement-Field Monitoring of Geotechnical Engineering Tian, Changbin Ma, Xiangxue Peng, Bo Ma, Xin Li, Zhiyu Sensors (Basel) Article Monitoring geotechnical structures and providing real-time early warning is a key measure to mitigate the impacts of disasters (slope slip, subsidence, dam deformation, bridge settlement, etc.). The fiber Bragg grating (FBG) flexible sensor, developed by the combination of flexible material and an FBG sensor, is widely used in geotechnical engineering health monitoring due to its excellent performance. The flexible sensor can perform regional and quasi-distributed measurements of the displacement field of the measured structure, and accurately reflect the operating state of the engineering structure. However, in practical engineering applications, factors such as the strain-transfer rate between the flexible substrate and sensing points, the displacement reconstruction algorithm, and the arrangement interval of the sensing points can cause measurement error, which, in turn, leads to a decrease in the displacement-measurement accuracy. In this paper, the following analysis is performed by means of theoretical derivation and model establishment. The influence of the length, width, and thickness of the cemented layer, the shear modulus of the flexible substrate, and the radius of the groove on the strain-transfer rate were analyzed, and the referential parameters were determined. The displacement reconstruction algorithm is essentially a recursive algorithm, which inevitably introduces cumulative error; the relationship between the layout interval of the sensing points and the measurement error is discussed. Considering the fabrication cost of the sensor and the allowable range of error, a sensing-point-layout interval of 100 mm was chosen. The feasibility and effectiveness of the simulation theory were verified by carrying out deformation-sensing experiments on the developed FBG flexible sensor. The research results can theoretically guide the packaging and fabrication of the FBG flexible sensor, thereby improving the measurement accuracy of the flexible sensor for the measured structure. MDPI 2022-09-21 /pmc/articles/PMC9573560/ /pubmed/36236277 http://dx.doi.org/10.3390/s22197168 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Tian, Changbin Ma, Xiangxue Peng, Bo Ma, Xin Li, Zhiyu Measurement-Error Analysis of Fiber Bragg Grating Flexible Sensor for Displacement-Field Monitoring of Geotechnical Engineering |
title | Measurement-Error Analysis of Fiber Bragg Grating Flexible Sensor for Displacement-Field Monitoring of Geotechnical Engineering |
title_full | Measurement-Error Analysis of Fiber Bragg Grating Flexible Sensor for Displacement-Field Monitoring of Geotechnical Engineering |
title_fullStr | Measurement-Error Analysis of Fiber Bragg Grating Flexible Sensor for Displacement-Field Monitoring of Geotechnical Engineering |
title_full_unstemmed | Measurement-Error Analysis of Fiber Bragg Grating Flexible Sensor for Displacement-Field Monitoring of Geotechnical Engineering |
title_short | Measurement-Error Analysis of Fiber Bragg Grating Flexible Sensor for Displacement-Field Monitoring of Geotechnical Engineering |
title_sort | measurement-error analysis of fiber bragg grating flexible sensor for displacement-field monitoring of geotechnical engineering |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9573560/ https://www.ncbi.nlm.nih.gov/pubmed/36236277 http://dx.doi.org/10.3390/s22197168 |
work_keys_str_mv | AT tianchangbin measurementerroranalysisoffiberbragggratingflexiblesensorfordisplacementfieldmonitoringofgeotechnicalengineering AT maxiangxue measurementerroranalysisoffiberbragggratingflexiblesensorfordisplacementfieldmonitoringofgeotechnicalengineering AT pengbo measurementerroranalysisoffiberbragggratingflexiblesensorfordisplacementfieldmonitoringofgeotechnicalengineering AT maxin measurementerroranalysisoffiberbragggratingflexiblesensorfordisplacementfieldmonitoringofgeotechnicalengineering AT lizhiyu measurementerroranalysisoffiberbragggratingflexiblesensorfordisplacementfieldmonitoringofgeotechnicalengineering |