Cargando…

Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy

This work presents an approach to the fast determination of a medical accelerator irradiation isocenter as a quality assurance (QA) procedure in radiotherapy. The isocenter determination tool is the tissue equivalent high-resolution 3D polymer gel dosimeter (PABIG(nx)) in a dedicated container combi...

Descripción completa

Detalles Bibliográficos
Autores principales: Maras, Piotr, Kozicki, Marek
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9573670/
https://www.ncbi.nlm.nih.gov/pubmed/36234149
http://dx.doi.org/10.3390/ma15196807
_version_ 1784810930648907776
author Maras, Piotr
Kozicki, Marek
author_facet Maras, Piotr
Kozicki, Marek
author_sort Maras, Piotr
collection PubMed
description This work presents an approach to the fast determination of a medical accelerator irradiation isocenter as a quality assurance (QA) procedure in radiotherapy. The isocenter determination tool is the tissue equivalent high-resolution 3D polymer gel dosimeter (PABIG(nx)) in a dedicated container combined with kilovoltage imaging systems and the polyGeVero-CT software package (v. 1.2, GeVero Co., Poland). Two accelerators were employed: Halcyon and TrueBeam (Varian, USA), both equipped with cone beam computed tomography (CBCT) and iterative reconstruction CBCT (iCBCT) algorithms. The scope of this work includes: (i) the examination of factors influencing image quality (reconstruction algorithms and modes), radiation field parameters (dose and multi-leaf collimator (MLC) gaps), fiducial markers, signal averaging for reconstruction algorithms and the scanning time interval between consecutive scans, (ii) the examination of factors influencing the isocenter determination, image processing (signal averaging, background subtraction, image filtering) and (iii) an isocenter determination report using a 2D and 3D approach. An optimized protocol and isocenter determination conditions were found. The time and effort required to determine the isocenter are discussed.
format Online
Article
Text
id pubmed-9573670
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-95736702022-10-17 Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy Maras, Piotr Kozicki, Marek Materials (Basel) Article This work presents an approach to the fast determination of a medical accelerator irradiation isocenter as a quality assurance (QA) procedure in radiotherapy. The isocenter determination tool is the tissue equivalent high-resolution 3D polymer gel dosimeter (PABIG(nx)) in a dedicated container combined with kilovoltage imaging systems and the polyGeVero-CT software package (v. 1.2, GeVero Co., Poland). Two accelerators were employed: Halcyon and TrueBeam (Varian, USA), both equipped with cone beam computed tomography (CBCT) and iterative reconstruction CBCT (iCBCT) algorithms. The scope of this work includes: (i) the examination of factors influencing image quality (reconstruction algorithms and modes), radiation field parameters (dose and multi-leaf collimator (MLC) gaps), fiducial markers, signal averaging for reconstruction algorithms and the scanning time interval between consecutive scans, (ii) the examination of factors influencing the isocenter determination, image processing (signal averaging, background subtraction, image filtering) and (iii) an isocenter determination report using a 2D and 3D approach. An optimized protocol and isocenter determination conditions were found. The time and effort required to determine the isocenter are discussed. MDPI 2022-09-30 /pmc/articles/PMC9573670/ /pubmed/36234149 http://dx.doi.org/10.3390/ma15196807 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Maras, Piotr
Kozicki, Marek
Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy
title Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy
title_full Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy
title_fullStr Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy
title_full_unstemmed Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy
title_short Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy
title_sort fast isocenter determination using 3d polymer gel dosimetry with kilovoltage cone-beam ct reading and the polygevero-ct software package for linac quality assurance in radiotherapy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9573670/
https://www.ncbi.nlm.nih.gov/pubmed/36234149
http://dx.doi.org/10.3390/ma15196807
work_keys_str_mv AT maraspiotr fastisocenterdeterminationusing3dpolymergeldosimetrywithkilovoltageconebeamctreadingandthepolygeveroctsoftwarepackageforlinacqualityassuranceinradiotherapy
AT kozickimarek fastisocenterdeterminationusing3dpolymergeldosimetrywithkilovoltageconebeamctreadingandthepolygeveroctsoftwarepackageforlinacqualityassuranceinradiotherapy