Calibration of a Catadioptric System and 3D Reconstruction Based on Surface Structured Light
In response to the problem of the small field of vision in 3D reconstruction, a 3D reconstruction system based on a catadioptric camera and projector was built by introducing a traditional camera to calibrate the catadioptric camera and projector system. Firstly, the intrinsic parameters of the came...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9573738/ https://www.ncbi.nlm.nih.gov/pubmed/36236487 http://dx.doi.org/10.3390/s22197385 |
_version_ | 1784810947955654656 |
---|---|
author | Lu, Zhenghai Lv, Yaowen Ai, Zhiqing Suo, Ke Gong, Xuanrui Wang, Yuxuan |
author_facet | Lu, Zhenghai Lv, Yaowen Ai, Zhiqing Suo, Ke Gong, Xuanrui Wang, Yuxuan |
author_sort | Lu, Zhenghai |
collection | PubMed |
description | In response to the problem of the small field of vision in 3D reconstruction, a 3D reconstruction system based on a catadioptric camera and projector was built by introducing a traditional camera to calibrate the catadioptric camera and projector system. Firstly, the intrinsic parameters of the camera and the traditional camera are calibrated separately. Then, the calibration of the projection system is accomplished by the traditional camera. Secondly, the coordinate system is introduced to calculate, respectively, the position of the catadioptric camera and projector in the coordinate system, and the position relationship between the coordinate systems of the catadioptric camera and the projector is obtained. Finally, the projector is used to project the structured light fringe to realize the reconstruction using a catadioptric camera. The experimental results show that the reconstruction error is 0.75 mm and the relative error is 0.0068 for a target of about 1 m. The calibration method and reconstruction method proposed in this paper can guarantee the ideal geometric reconstruction accuracy. |
format | Online Article Text |
id | pubmed-9573738 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-95737382022-10-17 Calibration of a Catadioptric System and 3D Reconstruction Based on Surface Structured Light Lu, Zhenghai Lv, Yaowen Ai, Zhiqing Suo, Ke Gong, Xuanrui Wang, Yuxuan Sensors (Basel) Article In response to the problem of the small field of vision in 3D reconstruction, a 3D reconstruction system based on a catadioptric camera and projector was built by introducing a traditional camera to calibrate the catadioptric camera and projector system. Firstly, the intrinsic parameters of the camera and the traditional camera are calibrated separately. Then, the calibration of the projection system is accomplished by the traditional camera. Secondly, the coordinate system is introduced to calculate, respectively, the position of the catadioptric camera and projector in the coordinate system, and the position relationship between the coordinate systems of the catadioptric camera and the projector is obtained. Finally, the projector is used to project the structured light fringe to realize the reconstruction using a catadioptric camera. The experimental results show that the reconstruction error is 0.75 mm and the relative error is 0.0068 for a target of about 1 m. The calibration method and reconstruction method proposed in this paper can guarantee the ideal geometric reconstruction accuracy. MDPI 2022-09-28 /pmc/articles/PMC9573738/ /pubmed/36236487 http://dx.doi.org/10.3390/s22197385 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lu, Zhenghai Lv, Yaowen Ai, Zhiqing Suo, Ke Gong, Xuanrui Wang, Yuxuan Calibration of a Catadioptric System and 3D Reconstruction Based on Surface Structured Light |
title | Calibration of a Catadioptric System and 3D Reconstruction Based on Surface Structured Light |
title_full | Calibration of a Catadioptric System and 3D Reconstruction Based on Surface Structured Light |
title_fullStr | Calibration of a Catadioptric System and 3D Reconstruction Based on Surface Structured Light |
title_full_unstemmed | Calibration of a Catadioptric System and 3D Reconstruction Based on Surface Structured Light |
title_short | Calibration of a Catadioptric System and 3D Reconstruction Based on Surface Structured Light |
title_sort | calibration of a catadioptric system and 3d reconstruction based on surface structured light |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9573738/ https://www.ncbi.nlm.nih.gov/pubmed/36236487 http://dx.doi.org/10.3390/s22197385 |
work_keys_str_mv | AT luzhenghai calibrationofacatadioptricsystemand3dreconstructionbasedonsurfacestructuredlight AT lvyaowen calibrationofacatadioptricsystemand3dreconstructionbasedonsurfacestructuredlight AT aizhiqing calibrationofacatadioptricsystemand3dreconstructionbasedonsurfacestructuredlight AT suoke calibrationofacatadioptricsystemand3dreconstructionbasedonsurfacestructuredlight AT gongxuanrui calibrationofacatadioptricsystemand3dreconstructionbasedonsurfacestructuredlight AT wangyuxuan calibrationofacatadioptricsystemand3dreconstructionbasedonsurfacestructuredlight |