Custom-made finger splint versus prefabricated finger splint: finger flexion stabilization

OBJECTIVE: Finger splints are used as a treatment option in tendon, bone, and soft tissue injuries. For immobilization, custom-made splints and prefabricated finger splints are used. In splints made for immobilization, it is aimed to limit joint movement. The aim of our study is to reveal how much c...

Descripción completa

Detalles Bibliográficos
Autores principales: Güven, Enver, Suner-Keklik, Sinem
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Associação Médica Brasileira 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9574959/
https://www.ncbi.nlm.nih.gov/pubmed/35946771
http://dx.doi.org/10.1590/1806-9282.20220093
_version_ 1784811216832561152
author Güven, Enver
Suner-Keklik, Sinem
author_facet Güven, Enver
Suner-Keklik, Sinem
author_sort Güven, Enver
collection PubMed
description OBJECTIVE: Finger splints are used as a treatment option in tendon, bone, and soft tissue injuries. For immobilization, custom-made splints and prefabricated finger splints are used. In splints made for immobilization, it is aimed to limit joint movement. The aim of our study is to reveal how much custom-made splints and prefabricated finger splints limit joint motion (flexion angle in proximal interphalangeal and distal interphalangeal joints). METHODS: Custom-made splints and prefabricated finger splints were applied to the second fingers of the dominant side in a total of 40 individuals, 20 women and 20 men, not having any health problems. Individuals were asked to flex and joint motion was measured with the iPhone compass application. RESULTS: The mean distal interphalangeal joint angle values of the participants measured by prefabricated finger splints were found to be 24.27±8.29, and the mean distal interphalangeal joint angle values measured by custom-made splints was 0.52±1.50. There was a difference between the participants’ distal interphalangeal joint angle values measured by prefabricated finger splints and custom-made splints (p<0.001). distal interphalangeal joint angle values measured with custom-made splints were significantly smaller than those measured with prefabricated finger splint. The mean of the participants’ proximal interphalangeal joint angle values measured by prefabricated finger splints was 16.55±7.90, and the proximal interphalangeal joint angle values measured by custom-made splints was “0” for all participants. There was a difference between the participants’ proximal interphalangeal joint angle values measured by prefabricated finger splints and custom-made splints (p<0.001). Distal interphalangeal joint angle values measured with custom-made splints were significantly smaller than those measured with prefabricated finger splints. CONCLUSION: According to our study, custom-made splints can significantly reduce the flexion of the finger interphalangeal joints compared to prefabricated finger splints.
format Online
Article
Text
id pubmed-9574959
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Associação Médica Brasileira
record_format MEDLINE/PubMed
spelling pubmed-95749592022-10-19 Custom-made finger splint versus prefabricated finger splint: finger flexion stabilization Güven, Enver Suner-Keklik, Sinem Rev Assoc Med Bras (1992) Original Article OBJECTIVE: Finger splints are used as a treatment option in tendon, bone, and soft tissue injuries. For immobilization, custom-made splints and prefabricated finger splints are used. In splints made for immobilization, it is aimed to limit joint movement. The aim of our study is to reveal how much custom-made splints and prefabricated finger splints limit joint motion (flexion angle in proximal interphalangeal and distal interphalangeal joints). METHODS: Custom-made splints and prefabricated finger splints were applied to the second fingers of the dominant side in a total of 40 individuals, 20 women and 20 men, not having any health problems. Individuals were asked to flex and joint motion was measured with the iPhone compass application. RESULTS: The mean distal interphalangeal joint angle values of the participants measured by prefabricated finger splints were found to be 24.27±8.29, and the mean distal interphalangeal joint angle values measured by custom-made splints was 0.52±1.50. There was a difference between the participants’ distal interphalangeal joint angle values measured by prefabricated finger splints and custom-made splints (p<0.001). distal interphalangeal joint angle values measured with custom-made splints were significantly smaller than those measured with prefabricated finger splint. The mean of the participants’ proximal interphalangeal joint angle values measured by prefabricated finger splints was 16.55±7.90, and the proximal interphalangeal joint angle values measured by custom-made splints was “0” for all participants. There was a difference between the participants’ proximal interphalangeal joint angle values measured by prefabricated finger splints and custom-made splints (p<0.001). Distal interphalangeal joint angle values measured with custom-made splints were significantly smaller than those measured with prefabricated finger splints. CONCLUSION: According to our study, custom-made splints can significantly reduce the flexion of the finger interphalangeal joints compared to prefabricated finger splints. Associação Médica Brasileira 2022-08-08 /pmc/articles/PMC9574959/ /pubmed/35946771 http://dx.doi.org/10.1590/1806-9282.20220093 Text en https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Güven, Enver
Suner-Keklik, Sinem
Custom-made finger splint versus prefabricated finger splint: finger flexion stabilization
title Custom-made finger splint versus prefabricated finger splint: finger flexion stabilization
title_full Custom-made finger splint versus prefabricated finger splint: finger flexion stabilization
title_fullStr Custom-made finger splint versus prefabricated finger splint: finger flexion stabilization
title_full_unstemmed Custom-made finger splint versus prefabricated finger splint: finger flexion stabilization
title_short Custom-made finger splint versus prefabricated finger splint: finger flexion stabilization
title_sort custom-made finger splint versus prefabricated finger splint: finger flexion stabilization
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9574959/
https://www.ncbi.nlm.nih.gov/pubmed/35946771
http://dx.doi.org/10.1590/1806-9282.20220093
work_keys_str_mv AT guvenenver custommadefingersplintversusprefabricatedfingersplintfingerflexionstabilization
AT sunerkekliksinem custommadefingersplintversusprefabricatedfingersplintfingerflexionstabilization