Cargando…

Assessment of postpartum haemorrhage for placenta accreta: Is measurement of myometrium thickness and dark intraplacental bands using MRI helpful?

BACKGROUND: This study aimed to investigate the predictive values of magnetic resonance imaging (MRI) myometrial thickness grading and dark intraplacental band (DIB) volumetry for blood loss in patients with placenta accreta spectrum (PAS). METHODS: Images and clinical data were acquired from patien...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Xinyi, Ming, Ying, Xu, Han, Xin, Yinghui, Yang, Lin, Liu, Zhiling, Han, Yuqing, Huang, Zhaoqin, Liu, Qingwei, Zhang, Jie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9575254/
https://www.ncbi.nlm.nih.gov/pubmed/36253716
http://dx.doi.org/10.1186/s12880-022-00906-2
_version_ 1784811278613610496
author Chen, Xinyi
Ming, Ying
Xu, Han
Xin, Yinghui
Yang, Lin
Liu, Zhiling
Han, Yuqing
Huang, Zhaoqin
Liu, Qingwei
Zhang, Jie
author_facet Chen, Xinyi
Ming, Ying
Xu, Han
Xin, Yinghui
Yang, Lin
Liu, Zhiling
Han, Yuqing
Huang, Zhaoqin
Liu, Qingwei
Zhang, Jie
author_sort Chen, Xinyi
collection PubMed
description BACKGROUND: This study aimed to investigate the predictive values of magnetic resonance imaging (MRI) myometrial thickness grading and dark intraplacental band (DIB) volumetry for blood loss in patients with placenta accreta spectrum (PAS). METHODS: Images and clinical data were acquired from patients who underwent placenta MRI examinations and were diagnosed with PAS from March 2015 to January 2021. Two radiologists jointly diagnosed, processed, and analysed the MR images of each patient. The analysis included MRI-based determination of placental attachment, as well as myometrial thickness grading and DIB volumetry. The patients included in the study were divided into three groups according to the estimated blood loss volume: in the general blood loss (GBL) group, the estimated blood loss volume was < 1000 ml; in the massive blood loss (MBL) group, the estimated blood loss volume was ≥ 1000 ml and < 2000 ml; and in the extremely massive blood loss (ex-MBL) group, the estimated blood loss volume was ≥ 2000 ml. The categorical, normally distributed, and non-normally distributed data were respectively analysed by the Chi-square, single-factor analysis of variance, and Kruskal–Wallis tests, respectively. The verification of correlation was completed by Spearman correlation analysis. The evaluation capabilities of indicators were assessed using receiver operating characteristic curves. RESULTS: Among 75 patients, 25 were included in the GBL group, 26 in the MBL group, and 24 in the ex-MBL group. A significant negative correlation was observed between the grade of myometrial thickness and the estimated blood loss (P < 0.001, ρ = − 0.604). There was a significant positive correlation between the volume of the DIB and the estimated blood loss (P < 0.001, ρ = 0.653). The areas under the receiver operating characteristic curve of the two MRI features for predicting blood loss ≥ 2000 ml were 0.776 and 0.897, respectively. CONCLUSIONS: The grading and volumetric MRI features, myometrial thickness, and volume of DIB, can be used as good prediction indicators of the risk of postpartum haemorrhage in patients with PAS.
format Online
Article
Text
id pubmed-9575254
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-95752542022-10-18 Assessment of postpartum haemorrhage for placenta accreta: Is measurement of myometrium thickness and dark intraplacental bands using MRI helpful? Chen, Xinyi Ming, Ying Xu, Han Xin, Yinghui Yang, Lin Liu, Zhiling Han, Yuqing Huang, Zhaoqin Liu, Qingwei Zhang, Jie BMC Med Imaging Research BACKGROUND: This study aimed to investigate the predictive values of magnetic resonance imaging (MRI) myometrial thickness grading and dark intraplacental band (DIB) volumetry for blood loss in patients with placenta accreta spectrum (PAS). METHODS: Images and clinical data were acquired from patients who underwent placenta MRI examinations and were diagnosed with PAS from March 2015 to January 2021. Two radiologists jointly diagnosed, processed, and analysed the MR images of each patient. The analysis included MRI-based determination of placental attachment, as well as myometrial thickness grading and DIB volumetry. The patients included in the study were divided into three groups according to the estimated blood loss volume: in the general blood loss (GBL) group, the estimated blood loss volume was < 1000 ml; in the massive blood loss (MBL) group, the estimated blood loss volume was ≥ 1000 ml and < 2000 ml; and in the extremely massive blood loss (ex-MBL) group, the estimated blood loss volume was ≥ 2000 ml. The categorical, normally distributed, and non-normally distributed data were respectively analysed by the Chi-square, single-factor analysis of variance, and Kruskal–Wallis tests, respectively. The verification of correlation was completed by Spearman correlation analysis. The evaluation capabilities of indicators were assessed using receiver operating characteristic curves. RESULTS: Among 75 patients, 25 were included in the GBL group, 26 in the MBL group, and 24 in the ex-MBL group. A significant negative correlation was observed between the grade of myometrial thickness and the estimated blood loss (P < 0.001, ρ = − 0.604). There was a significant positive correlation between the volume of the DIB and the estimated blood loss (P < 0.001, ρ = 0.653). The areas under the receiver operating characteristic curve of the two MRI features for predicting blood loss ≥ 2000 ml were 0.776 and 0.897, respectively. CONCLUSIONS: The grading and volumetric MRI features, myometrial thickness, and volume of DIB, can be used as good prediction indicators of the risk of postpartum haemorrhage in patients with PAS. BioMed Central 2022-10-17 /pmc/articles/PMC9575254/ /pubmed/36253716 http://dx.doi.org/10.1186/s12880-022-00906-2 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Chen, Xinyi
Ming, Ying
Xu, Han
Xin, Yinghui
Yang, Lin
Liu, Zhiling
Han, Yuqing
Huang, Zhaoqin
Liu, Qingwei
Zhang, Jie
Assessment of postpartum haemorrhage for placenta accreta: Is measurement of myometrium thickness and dark intraplacental bands using MRI helpful?
title Assessment of postpartum haemorrhage for placenta accreta: Is measurement of myometrium thickness and dark intraplacental bands using MRI helpful?
title_full Assessment of postpartum haemorrhage for placenta accreta: Is measurement of myometrium thickness and dark intraplacental bands using MRI helpful?
title_fullStr Assessment of postpartum haemorrhage for placenta accreta: Is measurement of myometrium thickness and dark intraplacental bands using MRI helpful?
title_full_unstemmed Assessment of postpartum haemorrhage for placenta accreta: Is measurement of myometrium thickness and dark intraplacental bands using MRI helpful?
title_short Assessment of postpartum haemorrhage for placenta accreta: Is measurement of myometrium thickness and dark intraplacental bands using MRI helpful?
title_sort assessment of postpartum haemorrhage for placenta accreta: is measurement of myometrium thickness and dark intraplacental bands using mri helpful?
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9575254/
https://www.ncbi.nlm.nih.gov/pubmed/36253716
http://dx.doi.org/10.1186/s12880-022-00906-2
work_keys_str_mv AT chenxinyi assessmentofpostpartumhaemorrhageforplacentaaccretaismeasurementofmyometriumthicknessanddarkintraplacentalbandsusingmrihelpful
AT mingying assessmentofpostpartumhaemorrhageforplacentaaccretaismeasurementofmyometriumthicknessanddarkintraplacentalbandsusingmrihelpful
AT xuhan assessmentofpostpartumhaemorrhageforplacentaaccretaismeasurementofmyometriumthicknessanddarkintraplacentalbandsusingmrihelpful
AT xinyinghui assessmentofpostpartumhaemorrhageforplacentaaccretaismeasurementofmyometriumthicknessanddarkintraplacentalbandsusingmrihelpful
AT yanglin assessmentofpostpartumhaemorrhageforplacentaaccretaismeasurementofmyometriumthicknessanddarkintraplacentalbandsusingmrihelpful
AT liuzhiling assessmentofpostpartumhaemorrhageforplacentaaccretaismeasurementofmyometriumthicknessanddarkintraplacentalbandsusingmrihelpful
AT hanyuqing assessmentofpostpartumhaemorrhageforplacentaaccretaismeasurementofmyometriumthicknessanddarkintraplacentalbandsusingmrihelpful
AT huangzhaoqin assessmentofpostpartumhaemorrhageforplacentaaccretaismeasurementofmyometriumthicknessanddarkintraplacentalbandsusingmrihelpful
AT liuqingwei assessmentofpostpartumhaemorrhageforplacentaaccretaismeasurementofmyometriumthicknessanddarkintraplacentalbandsusingmrihelpful
AT zhangjie assessmentofpostpartumhaemorrhageforplacentaaccretaismeasurementofmyometriumthicknessanddarkintraplacentalbandsusingmrihelpful