Cargando…

Evaluation of macular visibility through a high-order aspheric intraocular lens using a simulated model eye

We evaluated the macular visibility of a newly designed extended depth of focus (EDOF) intraocular lenses (IOL) using a wide viewing system for macular manipulation (Risight;60D, Carl Zeiss Meditec AG) in a model eye and compared it with various other types of IOLs. We used a model eye that was cons...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoshikawa, Yuji, Kanno, Junji, Shinoda, Kei, Makita, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9575836/
https://www.ncbi.nlm.nih.gov/pubmed/36253979
http://dx.doi.org/10.1097/MD.0000000000031018
_version_ 1784811398982795264
author Yoshikawa, Yuji
Kanno, Junji
Shinoda, Kei
Makita, Jun
author_facet Yoshikawa, Yuji
Kanno, Junji
Shinoda, Kei
Makita, Jun
author_sort Yoshikawa, Yuji
collection PubMed
description We evaluated the macular visibility of a newly designed extended depth of focus (EDOF) intraocular lenses (IOL) using a wide viewing system for macular manipulation (Risight;60D, Carl Zeiss Meditec AG) in a model eye and compared it with various other types of IOLs. We used a model eye that was constructed based on the Glustrand model to compare a newly designed EDOF IOL (DIB00V; Johnson & Johnson Surgical Vision), an EDOF IOL with a diffraction grating (ZXR00V; Johnson & Johnson surgical Vision), and a monofocal aspheric (DCB00V; Johnson & Johnson Vision, XY-1; HOYA Surgical Optics, Tokyo, Japan) or spherical IOL (NX70s; Santen Pharmaceutical Co., Ltd). In the model eye, a 1951 United States Air Force (USAF) test was placed at the location of the macula. The contrasts in a range of spatial frequencies were quantified using the images obtained from the 1951 USAF test target. The contrast at each spatial frequency was plotted and integrated to calculate the area under the curve contrast (AUC-contrast). Qualitative evaluations showed that good-quality images were obtained for all IOLs. At a spatial frequency of 16 LP/mm, the average contrast was the highest for the DIB00V and NX70s (0.216 each). The highest average contrast at 32 LP/mm was obtained using the NX70s (0.128), and at 64 LP/mm using the DIB00V (0.123). The horizontal AUC-contrast was the highest for the NX70s (8.754), and the vertical AUC-contrast was the highest for the DIB00V (8.334). On average, the DIB00V had the highest AUC-contrast value (8.227). The high-order aspheric IOL, DIB00V, was found to exhibit good macular visibility despite being an EDOF IOL.
format Online
Article
Text
id pubmed-9575836
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-95758362022-10-17 Evaluation of macular visibility through a high-order aspheric intraocular lens using a simulated model eye Yoshikawa, Yuji Kanno, Junji Shinoda, Kei Makita, Jun Medicine (Baltimore) 5800 We evaluated the macular visibility of a newly designed extended depth of focus (EDOF) intraocular lenses (IOL) using a wide viewing system for macular manipulation (Risight;60D, Carl Zeiss Meditec AG) in a model eye and compared it with various other types of IOLs. We used a model eye that was constructed based on the Glustrand model to compare a newly designed EDOF IOL (DIB00V; Johnson & Johnson Surgical Vision), an EDOF IOL with a diffraction grating (ZXR00V; Johnson & Johnson surgical Vision), and a monofocal aspheric (DCB00V; Johnson & Johnson Vision, XY-1; HOYA Surgical Optics, Tokyo, Japan) or spherical IOL (NX70s; Santen Pharmaceutical Co., Ltd). In the model eye, a 1951 United States Air Force (USAF) test was placed at the location of the macula. The contrasts in a range of spatial frequencies were quantified using the images obtained from the 1951 USAF test target. The contrast at each spatial frequency was plotted and integrated to calculate the area under the curve contrast (AUC-contrast). Qualitative evaluations showed that good-quality images were obtained for all IOLs. At a spatial frequency of 16 LP/mm, the average contrast was the highest for the DIB00V and NX70s (0.216 each). The highest average contrast at 32 LP/mm was obtained using the NX70s (0.128), and at 64 LP/mm using the DIB00V (0.123). The horizontal AUC-contrast was the highest for the NX70s (8.754), and the vertical AUC-contrast was the highest for the DIB00V (8.334). On average, the DIB00V had the highest AUC-contrast value (8.227). The high-order aspheric IOL, DIB00V, was found to exhibit good macular visibility despite being an EDOF IOL. Lippincott Williams & Wilkins 2022-10-14 /pmc/articles/PMC9575836/ /pubmed/36253979 http://dx.doi.org/10.1097/MD.0000000000031018 Text en Copyright © 2022 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle 5800
Yoshikawa, Yuji
Kanno, Junji
Shinoda, Kei
Makita, Jun
Evaluation of macular visibility through a high-order aspheric intraocular lens using a simulated model eye
title Evaluation of macular visibility through a high-order aspheric intraocular lens using a simulated model eye
title_full Evaluation of macular visibility through a high-order aspheric intraocular lens using a simulated model eye
title_fullStr Evaluation of macular visibility through a high-order aspheric intraocular lens using a simulated model eye
title_full_unstemmed Evaluation of macular visibility through a high-order aspheric intraocular lens using a simulated model eye
title_short Evaluation of macular visibility through a high-order aspheric intraocular lens using a simulated model eye
title_sort evaluation of macular visibility through a high-order aspheric intraocular lens using a simulated model eye
topic 5800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9575836/
https://www.ncbi.nlm.nih.gov/pubmed/36253979
http://dx.doi.org/10.1097/MD.0000000000031018
work_keys_str_mv AT yoshikawayuji evaluationofmacularvisibilitythroughahighorderasphericintraocularlensusingasimulatedmodeleye
AT kannojunji evaluationofmacularvisibilitythroughahighorderasphericintraocularlensusingasimulatedmodeleye
AT shinodakei evaluationofmacularvisibilitythroughahighorderasphericintraocularlensusingasimulatedmodeleye
AT makitajun evaluationofmacularvisibilitythroughahighorderasphericintraocularlensusingasimulatedmodeleye