Cargando…

Personalizing Revision Tibial Baseplate Position and Stem Trajectory With Custom Implants Using 3D Modeling to Optimize Press-fit Stem Placement

BACKGROUND: A common tibial construct for revision total knee arthroplasty includes a long diaphyseal engaging press-fit stem. Due to tibial canal bowing, compromises are often necessary to match patient anatomy when choosing stemmed implants. The objective of this study is to determine through 3-D...

Descripción completa

Detalles Bibliográficos
Autores principales: Cooperman, Charlotte, Wiznia, Daniel, Kunsel, Kunsel, Roytman, Gregory, Ani, Lidia, Pratola, Donald, Lee, Gwo-Chin, Tommasini, Steven, Bernstein, Jenna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9576531/
https://www.ncbi.nlm.nih.gov/pubmed/36267389
http://dx.doi.org/10.1016/j.artd.2022.08.011
_version_ 1784811551039946752
author Cooperman, Charlotte
Wiznia, Daniel
Kunsel, Kunsel
Roytman, Gregory
Ani, Lidia
Pratola, Donald
Lee, Gwo-Chin
Tommasini, Steven
Bernstein, Jenna
author_facet Cooperman, Charlotte
Wiznia, Daniel
Kunsel, Kunsel
Roytman, Gregory
Ani, Lidia
Pratola, Donald
Lee, Gwo-Chin
Tommasini, Steven
Bernstein, Jenna
author_sort Cooperman, Charlotte
collection PubMed
description BACKGROUND: A common tibial construct for revision total knee arthroplasty includes a long diaphyseal engaging press-fit stem. Due to tibial canal bowing, compromises are often necessary to match patient anatomy when choosing stemmed implants. The objective of this study is to determine through 3-D modeling whether current implant press-fit options appropriately fit patient anatomy, or whether an alternative angle between the stem and baseplate could increase the cortical engagement of long press-fit tibial stems. METHODS: Preoperative computerized tomography scans from 100 patients undergoing TKA were imported into an image-processing software program. Three-dimensional models were created with tibial stems placed at a fixed perpendicular angle and a custom angle to the revision tibial baseplate. Stem diameter, depth, offset, and contact surface area were measured and analyzed between the 2 groups. RESULTS: Significantly more cortical contact, larger stem diameter, and smaller offset of the custom keel from the center of the baseplate were associated with free custom tibial stem placement vs a fixed perpendicular baseplate-stem interface (P < .001). Statistically significant differences were also found between different patient demographics. CONCLUSIONS: Custom free-angle stem placement allows for increased stem diameter and cortical contact of press-fit tibial stems compared to existing constructs that must interface with the baseplate at a 90-degree angle. Current revision tibia implants limit fixation of tibial press-fit stems and often mismatch with patient anatomy. Alternative ways to fit patient anatomy may be beneficial for patients with extreme mismatch. In the future, custom keel angles may help to resolve this problem.
format Online
Article
Text
id pubmed-9576531
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-95765312022-10-19 Personalizing Revision Tibial Baseplate Position and Stem Trajectory With Custom Implants Using 3D Modeling to Optimize Press-fit Stem Placement Cooperman, Charlotte Wiznia, Daniel Kunsel, Kunsel Roytman, Gregory Ani, Lidia Pratola, Donald Lee, Gwo-Chin Tommasini, Steven Bernstein, Jenna Arthroplast Today Original Research BACKGROUND: A common tibial construct for revision total knee arthroplasty includes a long diaphyseal engaging press-fit stem. Due to tibial canal bowing, compromises are often necessary to match patient anatomy when choosing stemmed implants. The objective of this study is to determine through 3-D modeling whether current implant press-fit options appropriately fit patient anatomy, or whether an alternative angle between the stem and baseplate could increase the cortical engagement of long press-fit tibial stems. METHODS: Preoperative computerized tomography scans from 100 patients undergoing TKA were imported into an image-processing software program. Three-dimensional models were created with tibial stems placed at a fixed perpendicular angle and a custom angle to the revision tibial baseplate. Stem diameter, depth, offset, and contact surface area were measured and analyzed between the 2 groups. RESULTS: Significantly more cortical contact, larger stem diameter, and smaller offset of the custom keel from the center of the baseplate were associated with free custom tibial stem placement vs a fixed perpendicular baseplate-stem interface (P < .001). Statistically significant differences were also found between different patient demographics. CONCLUSIONS: Custom free-angle stem placement allows for increased stem diameter and cortical contact of press-fit tibial stems compared to existing constructs that must interface with the baseplate at a 90-degree angle. Current revision tibia implants limit fixation of tibial press-fit stems and often mismatch with patient anatomy. Alternative ways to fit patient anatomy may be beneficial for patients with extreme mismatch. In the future, custom keel angles may help to resolve this problem. Elsevier 2022-10-12 /pmc/articles/PMC9576531/ /pubmed/36267389 http://dx.doi.org/10.1016/j.artd.2022.08.011 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Cooperman, Charlotte
Wiznia, Daniel
Kunsel, Kunsel
Roytman, Gregory
Ani, Lidia
Pratola, Donald
Lee, Gwo-Chin
Tommasini, Steven
Bernstein, Jenna
Personalizing Revision Tibial Baseplate Position and Stem Trajectory With Custom Implants Using 3D Modeling to Optimize Press-fit Stem Placement
title Personalizing Revision Tibial Baseplate Position and Stem Trajectory With Custom Implants Using 3D Modeling to Optimize Press-fit Stem Placement
title_full Personalizing Revision Tibial Baseplate Position and Stem Trajectory With Custom Implants Using 3D Modeling to Optimize Press-fit Stem Placement
title_fullStr Personalizing Revision Tibial Baseplate Position and Stem Trajectory With Custom Implants Using 3D Modeling to Optimize Press-fit Stem Placement
title_full_unstemmed Personalizing Revision Tibial Baseplate Position and Stem Trajectory With Custom Implants Using 3D Modeling to Optimize Press-fit Stem Placement
title_short Personalizing Revision Tibial Baseplate Position and Stem Trajectory With Custom Implants Using 3D Modeling to Optimize Press-fit Stem Placement
title_sort personalizing revision tibial baseplate position and stem trajectory with custom implants using 3d modeling to optimize press-fit stem placement
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9576531/
https://www.ncbi.nlm.nih.gov/pubmed/36267389
http://dx.doi.org/10.1016/j.artd.2022.08.011
work_keys_str_mv AT coopermancharlotte personalizingrevisiontibialbaseplatepositionandstemtrajectorywithcustomimplantsusing3dmodelingtooptimizepressfitstemplacement
AT wizniadaniel personalizingrevisiontibialbaseplatepositionandstemtrajectorywithcustomimplantsusing3dmodelingtooptimizepressfitstemplacement
AT kunselkunsel personalizingrevisiontibialbaseplatepositionandstemtrajectorywithcustomimplantsusing3dmodelingtooptimizepressfitstemplacement
AT roytmangregory personalizingrevisiontibialbaseplatepositionandstemtrajectorywithcustomimplantsusing3dmodelingtooptimizepressfitstemplacement
AT anilidia personalizingrevisiontibialbaseplatepositionandstemtrajectorywithcustomimplantsusing3dmodelingtooptimizepressfitstemplacement
AT pratoladonald personalizingrevisiontibialbaseplatepositionandstemtrajectorywithcustomimplantsusing3dmodelingtooptimizepressfitstemplacement
AT leegwochin personalizingrevisiontibialbaseplatepositionandstemtrajectorywithcustomimplantsusing3dmodelingtooptimizepressfitstemplacement
AT tommasinisteven personalizingrevisiontibialbaseplatepositionandstemtrajectorywithcustomimplantsusing3dmodelingtooptimizepressfitstemplacement
AT bernsteinjenna personalizingrevisiontibialbaseplatepositionandstemtrajectorywithcustomimplantsusing3dmodelingtooptimizepressfitstemplacement