Cargando…
Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study
BACKGROUND: Inferior vena cava (IVC) ultrasonography is a reliable variable that predicts post-induction hypotension (PIH) in patients undergoing surgery under general anesthesia. However, in patients with hypertension, the predictive performance of ultrasound IVC measurements needs further explorat...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9576846/ https://www.ncbi.nlm.nih.gov/pubmed/36267641 http://dx.doi.org/10.3389/fcvm.2022.958259 |
_version_ | 1784811620156833792 |
---|---|
author | Zhang, Hanying Gao, Hongguang Xiang, Yuanjun Li, Junxiang |
author_facet | Zhang, Hanying Gao, Hongguang Xiang, Yuanjun Li, Junxiang |
author_sort | Zhang, Hanying |
collection | PubMed |
description | BACKGROUND: Inferior vena cava (IVC) ultrasonography is a reliable variable that predicts post-induction hypotension (PIH) in patients undergoing surgery under general anesthesia. However, in patients with hypertension, the predictive performance of ultrasound IVC measurements needs further exploration. METHODS: This is a prospective cohort study. Adult patients with existing hypertension scheduled to undergo non-cardiac surgery under general anesthesia were eligible. An abdominal ultrasound examination was conducted immediately prior to anesthesia induction (0.03 mg kg(–1) midazolam, 0.3 mg kg(–1) etomidate, 0.4 μg kg(–1) sufentanil, and 0.6 mg kg(–1) rocuronium). IVC collapsibility index (IVC-CI) was calculated as (dIVC(max)–dIVC(min))/dIVC(max), where dIVC(max) and dIVC(min) represent the maximum and minimum IVC diameters at the end of expiration and inspiration, respectively. PIH was defined as a reduction of mean arterial pressure (MAP) by >30% of the baseline or to <60 mmHg within 10 min after endotracheal intubation. The diagnostic performance of IVC-CI, dIVC(max), and dIVC(min) in predicting PIH was also examined in a group of normotensive patients receiving non-cardiac surgery under the same anesthesia protocol. RESULTS: A total of 51 hypertensive patients (61 ± 13 years of age, 31 women) and 52 normotensive patients (42 ± 13 years of age, 35 women) were included in the final analysis. PIH occurred in 33 (64.7%) hypertensive patients and 19 (36.5%) normotensive patients. In normotensive patients, the area under the receiver operating curve (AUC) in predicting PIH was 0.896 (95% confidence interval [CI]: 0.804–0.987) for IVC-CI, 0.770 (95% CI: 0.633–0.908) for dIVC(max), and 0.868 (95% CI: 0.773–0.963) for dIVC(min). In hypertensive patients, the AUC in predicting PIH was 0.523 (95% CI: 0.354–0.691) for IVC-CI, 0.752 (95% CI: 0.621–0.883) for dIVC(max), and 0.715 (95% CI: 0.571–0.858) for dIVC(min). At the optimal cutoff (1.24 cm), dIVC(max) had 54.5% (18/33) sensitivity and 94.4% (17/18) specificity. CONCLUSION: In hypertensive patients, IVC-CI is unsuitable for predicting PIH, and dIVC(max) is an alternative measure with promising performance. CLINICAL TRIAL REGISTRATION: [http://www.chictr.org.cn/], identifier [ChiCTR2000034853]. |
format | Online Article Text |
id | pubmed-9576846 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-95768462022-10-19 Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study Zhang, Hanying Gao, Hongguang Xiang, Yuanjun Li, Junxiang Front Cardiovasc Med Cardiovascular Medicine BACKGROUND: Inferior vena cava (IVC) ultrasonography is a reliable variable that predicts post-induction hypotension (PIH) in patients undergoing surgery under general anesthesia. However, in patients with hypertension, the predictive performance of ultrasound IVC measurements needs further exploration. METHODS: This is a prospective cohort study. Adult patients with existing hypertension scheduled to undergo non-cardiac surgery under general anesthesia were eligible. An abdominal ultrasound examination was conducted immediately prior to anesthesia induction (0.03 mg kg(–1) midazolam, 0.3 mg kg(–1) etomidate, 0.4 μg kg(–1) sufentanil, and 0.6 mg kg(–1) rocuronium). IVC collapsibility index (IVC-CI) was calculated as (dIVC(max)–dIVC(min))/dIVC(max), where dIVC(max) and dIVC(min) represent the maximum and minimum IVC diameters at the end of expiration and inspiration, respectively. PIH was defined as a reduction of mean arterial pressure (MAP) by >30% of the baseline or to <60 mmHg within 10 min after endotracheal intubation. The diagnostic performance of IVC-CI, dIVC(max), and dIVC(min) in predicting PIH was also examined in a group of normotensive patients receiving non-cardiac surgery under the same anesthesia protocol. RESULTS: A total of 51 hypertensive patients (61 ± 13 years of age, 31 women) and 52 normotensive patients (42 ± 13 years of age, 35 women) were included in the final analysis. PIH occurred in 33 (64.7%) hypertensive patients and 19 (36.5%) normotensive patients. In normotensive patients, the area under the receiver operating curve (AUC) in predicting PIH was 0.896 (95% confidence interval [CI]: 0.804–0.987) for IVC-CI, 0.770 (95% CI: 0.633–0.908) for dIVC(max), and 0.868 (95% CI: 0.773–0.963) for dIVC(min). In hypertensive patients, the AUC in predicting PIH was 0.523 (95% CI: 0.354–0.691) for IVC-CI, 0.752 (95% CI: 0.621–0.883) for dIVC(max), and 0.715 (95% CI: 0.571–0.858) for dIVC(min). At the optimal cutoff (1.24 cm), dIVC(max) had 54.5% (18/33) sensitivity and 94.4% (17/18) specificity. CONCLUSION: In hypertensive patients, IVC-CI is unsuitable for predicting PIH, and dIVC(max) is an alternative measure with promising performance. CLINICAL TRIAL REGISTRATION: [http://www.chictr.org.cn/], identifier [ChiCTR2000034853]. Frontiers Media S.A. 2022-10-04 /pmc/articles/PMC9576846/ /pubmed/36267641 http://dx.doi.org/10.3389/fcvm.2022.958259 Text en Copyright © 2022 Zhang, Gao, Xiang and Li. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Cardiovascular Medicine Zhang, Hanying Gao, Hongguang Xiang, Yuanjun Li, Junxiang Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study |
title | Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study |
title_full | Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study |
title_fullStr | Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study |
title_full_unstemmed | Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study |
title_short | Maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: A prospective cohort study |
title_sort | maximum inferior vena cava diameter predicts post-induction hypotension in hypertensive patients undergoing non-cardiac surgery under general anesthesia: a prospective cohort study |
topic | Cardiovascular Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9576846/ https://www.ncbi.nlm.nih.gov/pubmed/36267641 http://dx.doi.org/10.3389/fcvm.2022.958259 |
work_keys_str_mv | AT zhanghanying maximuminferiorvenacavadiameterpredictspostinductionhypotensioninhypertensivepatientsundergoingnoncardiacsurgeryundergeneralanesthesiaaprospectivecohortstudy AT gaohongguang maximuminferiorvenacavadiameterpredictspostinductionhypotensioninhypertensivepatientsundergoingnoncardiacsurgeryundergeneralanesthesiaaprospectivecohortstudy AT xiangyuanjun maximuminferiorvenacavadiameterpredictspostinductionhypotensioninhypertensivepatientsundergoingnoncardiacsurgeryundergeneralanesthesiaaprospectivecohortstudy AT lijunxiang maximuminferiorvenacavadiameterpredictspostinductionhypotensioninhypertensivepatientsundergoingnoncardiacsurgeryundergeneralanesthesiaaprospectivecohortstudy |