Setup error assessment based on “Sphere-Mask” Optical Positioning System: Results from a multicenter study

BACKGROUND: The setup accuracy plays an extremely important role in the local control of tumors. The purpose of this study is to verify the feasibility of "Sphere-Mask" Optical Positioning System (S-M_OPS) for fast and accurate setup. METHODS: From 2016 to 2021, we used S-M_OPS to supervis...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Yan, Zhou, Han, Chu, Kaiyue, Wu, Chuanfeng, Ge, Yun, Shan, Guoping, Zhou, Jundong, Cai, Jing, Jin, Jianhua, Sun, Weiyu, Chen, Ying, Huang, Xiaolin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9577199/
https://www.ncbi.nlm.nih.gov/pubmed/36267985
http://dx.doi.org/10.3389/fonc.2022.918296
_version_ 1784811705548668928
author Zhang, Yan
Zhou, Han
Chu, Kaiyue
Wu, Chuanfeng
Ge, Yun
Shan, Guoping
Zhou, Jundong
Cai, Jing
Jin, Jianhua
Sun, Weiyu
Chen, Ying
Huang, Xiaolin
author_facet Zhang, Yan
Zhou, Han
Chu, Kaiyue
Wu, Chuanfeng
Ge, Yun
Shan, Guoping
Zhou, Jundong
Cai, Jing
Jin, Jianhua
Sun, Weiyu
Chen, Ying
Huang, Xiaolin
author_sort Zhang, Yan
collection PubMed
description BACKGROUND: The setup accuracy plays an extremely important role in the local control of tumors. The purpose of this study is to verify the feasibility of "Sphere-Mask" Optical Positioning System (S-M_OPS) for fast and accurate setup. METHODS: From 2016 to 2021, we used S-M_OPS to supervise 15441 fractions in 1981patients (with the cancer in intracalvarium, nasopharynx, esophagus, lung, liver, abdomen or cervix) undergoing intensity-modulated radiation therapy (IMRT), and recorded the data such as registration time and mask deformation. Then, we used S-M_OPS, laser line and cone beam computed tomography (CBCT) for co-setup in 277 fractions, and recorded laser line-guided setup errors and S-M_OPS-guided setup errors with CBCT-guided setup result as the standard. RESULTS: S-M_OPS supervision results: The average time for laser line-guided setup was 31.75s. 12.8% of the reference points had an average deviation of more than 2 mm and 5.2% of the reference points had an average deviation of more than 3 mm. Co-setup results: The average time for S-M_OPS-guided setup was 7.47s, and average time for CBCT-guided setup was 228.84s (including time for CBCT scan and manual verification). In the LAT (left/right), VRT (superior/inferior) and LNG (anterior/posterior) directions, laser line-guided setup errors (mean±SD) were -0.21±3.13mm, 1.02±2.76mm and 2.22±4.26mm respectively; the 95% confidence intervals (95% CIs) of laser line-guided setup errors were -6.35 to 5.93mm, -4.39 to 6.43mm and -6.14 to 10.58mm respectively; S-M_OPS-guided setup errors were 0.12±1.91mm, 1.02±1.81mm and -0.10±2.25mm respectively; the 95% CIs of S-M_OPS-guided setup errors were -3.86 to 3.62mm, -2.53 to 4.57mm and -4.51 to 4.31mm respectively. CONCLUSION: S-M_OPS can greatly improve setup accuracy and stability compared with laser line-guided setup. Furthermore, S-M_OPS can provide comparable setup accuracy to CBCT in less setup time.
format Online
Article
Text
id pubmed-9577199
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-95771992022-10-19 Setup error assessment based on “Sphere-Mask” Optical Positioning System: Results from a multicenter study Zhang, Yan Zhou, Han Chu, Kaiyue Wu, Chuanfeng Ge, Yun Shan, Guoping Zhou, Jundong Cai, Jing Jin, Jianhua Sun, Weiyu Chen, Ying Huang, Xiaolin Front Oncol Oncology BACKGROUND: The setup accuracy plays an extremely important role in the local control of tumors. The purpose of this study is to verify the feasibility of "Sphere-Mask" Optical Positioning System (S-M_OPS) for fast and accurate setup. METHODS: From 2016 to 2021, we used S-M_OPS to supervise 15441 fractions in 1981patients (with the cancer in intracalvarium, nasopharynx, esophagus, lung, liver, abdomen or cervix) undergoing intensity-modulated radiation therapy (IMRT), and recorded the data such as registration time and mask deformation. Then, we used S-M_OPS, laser line and cone beam computed tomography (CBCT) for co-setup in 277 fractions, and recorded laser line-guided setup errors and S-M_OPS-guided setup errors with CBCT-guided setup result as the standard. RESULTS: S-M_OPS supervision results: The average time for laser line-guided setup was 31.75s. 12.8% of the reference points had an average deviation of more than 2 mm and 5.2% of the reference points had an average deviation of more than 3 mm. Co-setup results: The average time for S-M_OPS-guided setup was 7.47s, and average time for CBCT-guided setup was 228.84s (including time for CBCT scan and manual verification). In the LAT (left/right), VRT (superior/inferior) and LNG (anterior/posterior) directions, laser line-guided setup errors (mean±SD) were -0.21±3.13mm, 1.02±2.76mm and 2.22±4.26mm respectively; the 95% confidence intervals (95% CIs) of laser line-guided setup errors were -6.35 to 5.93mm, -4.39 to 6.43mm and -6.14 to 10.58mm respectively; S-M_OPS-guided setup errors were 0.12±1.91mm, 1.02±1.81mm and -0.10±2.25mm respectively; the 95% CIs of S-M_OPS-guided setup errors were -3.86 to 3.62mm, -2.53 to 4.57mm and -4.51 to 4.31mm respectively. CONCLUSION: S-M_OPS can greatly improve setup accuracy and stability compared with laser line-guided setup. Furthermore, S-M_OPS can provide comparable setup accuracy to CBCT in less setup time. Frontiers Media S.A. 2022-10-04 /pmc/articles/PMC9577199/ /pubmed/36267985 http://dx.doi.org/10.3389/fonc.2022.918296 Text en Copyright © 2022 Zhang, Zhou, Chu, Wu, Ge, Shan, Zhou, Cai, Jin, Sun, Chen and Huang https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Oncology
Zhang, Yan
Zhou, Han
Chu, Kaiyue
Wu, Chuanfeng
Ge, Yun
Shan, Guoping
Zhou, Jundong
Cai, Jing
Jin, Jianhua
Sun, Weiyu
Chen, Ying
Huang, Xiaolin
Setup error assessment based on “Sphere-Mask” Optical Positioning System: Results from a multicenter study
title Setup error assessment based on “Sphere-Mask” Optical Positioning System: Results from a multicenter study
title_full Setup error assessment based on “Sphere-Mask” Optical Positioning System: Results from a multicenter study
title_fullStr Setup error assessment based on “Sphere-Mask” Optical Positioning System: Results from a multicenter study
title_full_unstemmed Setup error assessment based on “Sphere-Mask” Optical Positioning System: Results from a multicenter study
title_short Setup error assessment based on “Sphere-Mask” Optical Positioning System: Results from a multicenter study
title_sort setup error assessment based on “sphere-mask” optical positioning system: results from a multicenter study
topic Oncology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9577199/
https://www.ncbi.nlm.nih.gov/pubmed/36267985
http://dx.doi.org/10.3389/fonc.2022.918296
work_keys_str_mv AT zhangyan setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT zhouhan setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT chukaiyue setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT wuchuanfeng setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT geyun setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT shanguoping setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT zhoujundong setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT caijing setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT jinjianhua setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT sunweiyu setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT chenying setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy
AT huangxiaolin setuperrorassessmentbasedonspheremaskopticalpositioningsystemresultsfromamulticenterstudy