Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars

This work evaluates the internal and marginal adaptation of implant-assisted overdenture cobalt–chromium (Co–Cr) bars manufactured using conventional as well as CAD/CAM subtractive and selective laser melting (SLM) utilizing two scanning techniques. Methods: An edentulous study model containing four...

Descripción completa

Detalles Bibliográficos
Autores principales: Alenezi, Ali, Yehya, Mohammed, Alkhodary, Mohamed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9577350/
https://www.ncbi.nlm.nih.gov/pubmed/36267525
http://dx.doi.org/10.1016/j.sdentj.2022.08.007
_version_ 1784811736096833536
author Alenezi, Ali
Yehya, Mohammed
Alkhodary, Mohamed
author_facet Alenezi, Ali
Yehya, Mohammed
Alkhodary, Mohamed
author_sort Alenezi, Ali
collection PubMed
description This work evaluates the internal and marginal adaptation of implant-assisted overdenture cobalt–chromium (Co–Cr) bars manufactured using conventional as well as CAD/CAM subtractive and selective laser melting (SLM) utilizing two scanning techniques. Methods: An edentulous study model containing four dental implants placed at teeth sites 36, 33, 43, and 46 was used. The study cast was scanned and compared to the virtual casts developed from two scanning techniques, straight and zigzag motion, using the in silico superimposition process. Then, conventional techniques were used to produce full-arch bars that were compared to the bars fabricated using the two scanning techniques and CAD/CAM subtractive and additive techniques. Results: The conventional impression and casting techniques had the smallest marginal gap among the groups (P-value < 0.05). The CAD/CAM subtractive milling techniques in groups II and III had significantly smaller marginal gaps than SLM technique used in groups IV and V (P-value < 0.05). The analysis of the internal gap within each group showed statistically significant differences between different implant sites in all groups (P-value < 0.001), except when using the conventional impression and casting techniques in group I (P-value = 0.20). Conclusion: The conventional impression and fabrication techniques were better than the digital impression and CAD/CAM subtractive and additive techniques for the fabrication of full-arch bars. However, both straight and zigzag scanning techniques and the CAD/CAM subtractive technique had marginal and internal gaps that were within clinically accepted ranges, and the SLM was found to be unsuitable for long-span framework fabrication with either scanning technique used.
format Online
Article
Text
id pubmed-9577350
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-95773502022-10-19 Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars Alenezi, Ali Yehya, Mohammed Alkhodary, Mohamed Saudi Dent J Original Article This work evaluates the internal and marginal adaptation of implant-assisted overdenture cobalt–chromium (Co–Cr) bars manufactured using conventional as well as CAD/CAM subtractive and selective laser melting (SLM) utilizing two scanning techniques. Methods: An edentulous study model containing four dental implants placed at teeth sites 36, 33, 43, and 46 was used. The study cast was scanned and compared to the virtual casts developed from two scanning techniques, straight and zigzag motion, using the in silico superimposition process. Then, conventional techniques were used to produce full-arch bars that were compared to the bars fabricated using the two scanning techniques and CAD/CAM subtractive and additive techniques. Results: The conventional impression and casting techniques had the smallest marginal gap among the groups (P-value < 0.05). The CAD/CAM subtractive milling techniques in groups II and III had significantly smaller marginal gaps than SLM technique used in groups IV and V (P-value < 0.05). The analysis of the internal gap within each group showed statistically significant differences between different implant sites in all groups (P-value < 0.001), except when using the conventional impression and casting techniques in group I (P-value = 0.20). Conclusion: The conventional impression and fabrication techniques were better than the digital impression and CAD/CAM subtractive and additive techniques for the fabrication of full-arch bars. However, both straight and zigzag scanning techniques and the CAD/CAM subtractive technique had marginal and internal gaps that were within clinically accepted ranges, and the SLM was found to be unsuitable for long-span framework fabrication with either scanning technique used. Elsevier 2022-11 2022-08-28 /pmc/articles/PMC9577350/ /pubmed/36267525 http://dx.doi.org/10.1016/j.sdentj.2022.08.007 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Alenezi, Ali
Yehya, Mohammed
Alkhodary, Mohamed
Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars
title Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars
title_full Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars
title_fullStr Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars
title_full_unstemmed Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars
title_short Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars
title_sort effect of full arch two scanning techniques on the accuracy of overdenture conventional and cad/cam co-cr bars
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9577350/
https://www.ncbi.nlm.nih.gov/pubmed/36267525
http://dx.doi.org/10.1016/j.sdentj.2022.08.007
work_keys_str_mv AT aleneziali effectoffullarchtwoscanningtechniquesontheaccuracyofoverdentureconventionalandcadcamcocrbars
AT yehyamohammed effectoffullarchtwoscanningtechniquesontheaccuracyofoverdentureconventionalandcadcamcocrbars
AT alkhodarymohamed effectoffullarchtwoscanningtechniquesontheaccuracyofoverdentureconventionalandcadcamcocrbars